Scanner Emulation Interface Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Connecting Using Scanner Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 Scanner Emulation Parameter Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4 Scanner Emulation Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-5 Scanner Emulation Host Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-5 Beep Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-5 Parameter Pass-Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6 Convert Newer Code Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-7 Module Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-8 Convert All Bar Codes to Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-8 Code 39 Full ASCII Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-9 Transmission Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-9 Ignore Unknown Characters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-11 Leading Margin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12 Check For Decode LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
Page 148
11-2 DS6608 Product Reference Guide
Page 149
Scanner Emulation Interface 11-3
Introduction This chapter describes how to set up the digital scanner with a Scanner Emulation host. Use this mode when Scanner Emulation communication is needed. In this mode, the digital scanner connects to an external decoder or to a decoder integrated in a mobile computer or Point-of-Sale (POS) terminal. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*Parameter Process and
Feature/Option
Pass-Through
Note
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.
Connecting Using Scanner Emulation To perform Scanner Emulation, connect the digital scanner to a mobile computer, or a controller which collects the data and interprets it for the host. Host Port Connector
Interface Cable
Figure 11-1. Scanner Emulation Connection
Note
Interface cables vary depending on configuration. The connectors illustrated in Figure 11-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.
1. Attach the modular connector of the Scanner Emulation interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Connect the other end of the Scanner Emulation interface cable to the scanner port on the mobile computer or controller.
Page 150
11-4 DS6608 Product Reference Guide
3. Scan the Scanner Emulation Host bar code from Scanner Emulation Host on page 11-5 to enable the Scanner Emulation host interface. 4. To modify any other parameter options, scan the appropriate bar codes in this chapter. Connect the digital scanner to 5 volt decoders only. Connecting the digital scanner to a 12 volt decoder can damage the digital scanner and invalidate the warranty.
WARNING
Scanner Emulation Parameter Defaults Table 11-1 lists the defaults for the Scanner Emulation host. To change any option, scan the appropriate bar code(s) provided in the Scanner Emulation Host Parameters section beginning on page 11-5. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Note
Table 11-1. Scanner Emulation Default Table Parameter
Default
Page Number
Beep Style
Beep on Successful Transmit
11-5
Parameter Pass-Through
Parameter Process and Pass Through
11-6
Convert Newer Code Types
Convert Newer Code Types
11-7
Module Width
20 µs
11-8
Convert All Bar Codes to Code 39
Do Not Convert to Bar Codes to Code 39
11-8
Code 39 Full ASCII Conversion
Disable
11-9
Transmission Timeout
3 seconds
11-9
Ignore Unknown Characters
Ignore Unknown Characters
11-11
Leading Margin
2 ms
11-12
Check for Decode LED
Check for Decode LED
11-13
Page 151
Scanner Emulation Interface 11-5
Scanner Emulation Host Scan the bar code below to enable the Scanner Emulation host.
Scanner Emulation Host
Scanner Emulation Host Parameters Beep Style The Scanner Emulation host supports three beep styles. • •
•
Beep On Successful Transmit: The digital scanner beeps when the attached decoder issues the decode signal to the digital scanner, so the digital scanner and the attached decoder beep at the same time. Beep At Decode Time: The digital scanner beeps upon decode. This results in a double beep sequence from most decoders, since the digital scanner beeps, and the decoder beeps (at a different frequency) when it successfully decodes the output. Do Not Beep: Only the attached decoder issues the decode beep.
In all cases, if an error occurs, the digital scanner issues error beeps.
*Beep On Successful Transmit
Beep At Decode Time
Do Not Beep
Page 152
11-6 DS6608 Product Reference Guide
Parameter Pass-Through The Scanner Emulation host can process parameter bar code messages and send them to the attached decoder. In this way, customers using Symbol compliant decoders can control the behavior of the entire system by scanning the necessary parameters only once. For example, to enable D 2 of 5, scan the D 2 of 5 Enable parameter bar code. The digital scanner and the attached decoder both process the parameter.
*Parameter Process and Pass-Through
Parameter Process Only
Page 153
Scanner Emulation Interface 11-7
Convert Newer Code Types The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow compatibility in these environments, the digital scanner converts these code types to more commonly decodable symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally. Scan this code type:
Transmitted as:
Code 11
Code 39
RSS (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF, MaxiCode, DataMatrix, QR Code, Postal Codes, Composite Codes
Code 128
When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the conversion code type.
*Convert Newer Code Types
Reject Newer Code Types
Page 154
11-8 DS6608 Product Reference Guide
Module Width The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.
*20 µs Module Width
50 µs Module Width
Convert All Bar Codes to Code 39 Scan a bar code below to enable or disable the conversion of all bar code data to Code 39.
*Do Not Convert Bar Codes To Code 39
Convert All To Code 39
Page 155
Scanner Emulation Interface 11-9
Code 39 Full ASCII Conversion By default, any characters that do not have a corresponding character in the Code 39 symbology set are replaced by a space. If this parameter is enabled, the data sent to the Scanner Emulation host is encoded in Code 39 Full ASCII. The host must be able to interpret Code 39 Full ASCII data. This setting applies only if Convert to Code 39 is also enabled.
*Disable Convert Code 39 To Full ASCII
Enable Convert Code 39 To Full ASCII
Scanner Emulation emits an error beep and does not send any data if the scanned data exceeds the maximum length for Code 39.
Note
Transmission Timeout The Scanner Emulation host transmits bar code data to the attached decoder and waits for the decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time, the Decode signal is not asserted (indicating that the attached decoder has not successfully received the bar code data), the digital scanner issues transmit error beeps. Scan the appropriate bar code below to select the desired transmission timeout.
*3 Second Transmission Timeout
4 Second Transmission Timeout
Page 156
11-10 DS6608 Product Reference Guide
5 Second Transmission Timeout
Page 157
Scanner Emulation Interface 11-11
Transmission Timeout (continued)
10 Second Transmission Timeout
30 Second Transmission Timeout
Ignore Unknown Characters Unknown characters are characters the decoder does not recognize. When Ignore Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Convert Error on Unknown Characters is selected, bar codes containing at least one unknown character are not sent to the decoder, and a convert error beep sounds.
*Ignore Unknown Characters
Convert Error On Unknown Characters
Page 158
11-12 DS6608 Product Reference Guide
Leading Margin Scan a bar code below to select a leading margin duration.
1 ms Leading Margin
*2 ms Leading Margin
3 ms Leading Margin
5 ms Leading Margin
10 ms Leading Margin
Page 159
Scanner Emulation Interface 11-13
Check For Decode LED The attached decoder normally asserts the Decode line to signal to the Scanner Emulation host that it successfully decoded the transmitted bar code. Some decoders, however, do not assert the Decode signal. In this case, the digital scanner emits transmit error beeps to indicate that the bar code was not successfully transmitted. Scan the Ignore Decode LED bar code to disable the Transmit Error beeps.
*Check For Decode LED
Ignore Decode LED