Page 101

RS-232 Interface 7-17

Software Handshaking (continued)

ACK/NAK with ENQ

XON/XOFF

Host Serial Response Time-out This parameter specifies how long the digital scanner waits for an ACK, NAK, or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option.

*Minimum: 2 Sec

Low: 2.5 Sec

Medium: 5 Sec

High: 7.5 Sec

Page 102

7-18 DS6608 Product Reference Guide

Host Serial Response Time-out (continued)

Maximum: 9.9 Sec

RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state.

*Host: Low RTS

Host: High RTS

Beep on <BEL> When this parameter is enabled, the digital scanner issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.

Beep On <BEL> Character (Enable)

*Do Not Beep On <BEL> Character (Disable)

Page 103

RS-232 Interface 7-19

Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions.

*Minimum: 0 msec

Low: 25 msec

Medium: 50 msec

High: 75 msec

Maximum: 99 msec

Page 104

7-20 DS6608 Product Reference Guide

Nixdorf Beep/LED Options When Nixdorf Mode B is selected, this indicates when the digital scanner should beep and turn on its LED after a decode.

*Normal Operation (Beep/LED immediately after decode)

Beep/LED After Transmission

Beep/LED After CTS Pulse

Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes with Unknown Characters is selected, all bar code data is send except for unknown characters, and no error beeps sound on the digital scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character and then an error beep will sound on the digital scanner.

*Send Bar Code (with unknown characters)

Do Not Send Bar Codes (with unknown characters)

Page 105

RS-232 Interface 7-21

ASCII Character Set for RS-232 The values in Table 7-4 can be assigned as prefixes or suffixes for ASCII character data transmission.

Table 7-4. Prefix/Suffix Values Prefix/Suffix Value

Full ASCII Code 39 Encode Character

ASCII Character

1000

%U

NUL

1001

$A

SOH

1002

$B

STX

1003

$C

ETX

1004

$D

EOT

1005

$E

ENQ

1006

$F

ACK

1007

$G

BELL

1008

$H

BCKSPC

1009

$I

HORIZ TAB

1010

$J

LF/NW LN

1011

$K

VT

1012

$L

FF

1013

$M

CR/ENTER

1014

$N

SO

1015

$O

SI

1016

$P

DLE

1017

$Q

DC1/XON

1018

$R

DC2

1019

$S

DC3/XOFF

1020

$T

DC4

1021

$U

NAK

1022

$V

SYN

1023

$W

ETB

1024

$X

CAN

1025

$Y

EM

1026

$Z

SUB

1027

%A

ESC

1028

%B

FS

1029

%C

GS

1030

%D

RS

1031

%E

US

1032

Space

Space

Page 106

7-22 DS6608 Product Reference Guide

Table 7-4. Prefix/Suffix Values (Continued) Prefix/Suffix Value

Full ASCII Code 39 Encode Character

ASCII Character

1033

/A

!

1034

/B

"

1035

/C

#

1036

/D

$

1037

/E

%

1038

/F

&

1039

/G

‘

1040

/H

(

1041

/I

)

1042

/J

*

1043

/K

+

1044

/L

,

1045

-

-

1046

.

.

1047

/O

/

1048

0

0

1049

1

1

1050

2

2

1051

3

3

1052

4

4

1053

5

5

1054

6

6

1055

7

7

1056

8

8

1057

9

9

1058

/Z

:

1059

%F

;

1060

%G

<

1061

%H

=

1062

%I

>

1063

%J

?

1064

%V

@

1065

A

A

1066

B

B

1067

C

C

Page 107

RS-232 Interface 7-23

Table 7-4. Prefix/Suffix Values (Continued) Prefix/Suffix Value

Full ASCII Code 39 Encode Character

ASCII Character

1068

D

D

1069

E

E

1070

F

F

1071

G

G

1072

H

H

1073

I

I

1074

J

J

1075

K

K

1076

L

L

1077

M

M

1078

N

N

1079

O

O

1080

P

P

1081

Q

Q

1082

R

R

1083

S

S

1084

T

T

1085

U

U

1086

V

V

1087

W

W

1088

X

X

1089

Y

Y

1090

Z

Z

1091

%K

[

1092

%L

\

1093

%M

]

1094

%N

^

1095

%O

_

1096

%W

`

1097

+A a

1098

+B b

1099

+C c

1100

+D d

1101

+E e

1102

+F f

Page 108

7-24 DS6608 Product Reference Guide

Table 7-4. Prefix/Suffix Values (Continued) Prefix/Suffix Value

Full ASCII Code 39 Encode Character

ASCII Character

1103

+G g

1104

+H h

1105

+I i

1106

+J j

1107

+K k

1108

+L l

1109

+M m

1110

+N n

1111

+O o

1112

+P p

1113

+Q q

1114

+R r

1115

+S s

1116

+T t

1117

+U u

1118

+V v

1119

+W w

1120

+X x

1121

+Y y

1122

+Z z

1123

%P

{

1124

%Q

|

1125

%R

}

1126

%S

~

1127

Undefined

7013

ENTER