Page 85

RS-232 Interface Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Connecting an RS-232 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4 RS-232 Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5 RS-232 Host Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6 RS-232 Host Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 Parity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 Stop Bit Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Data Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 Check Receive Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 Hardware Handshaking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 Hardware Handshaking (continued). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15 Software Handshaking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16 Host Serial Response Time-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17 RTS Line State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18 Beep on <BEL> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18 Intercharacter Delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-19 Nixdorf Beep/LED Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-20 Ignore Unknown Characters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 ASCII Character Set for RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-21

Page 86

7-2 DS6608 Product Reference Guide

Page 87

RS-232 Interface 7-3

Introduction This chapter describes how to set up the digital scanner with an RS-232 host. The RS-232 interface is used to connect the digital scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If the host is not listed in Table 7-2, refer to the documentation for the host device to set communication parameters to match the host.

Note

The digital scanner uses TTL RS-232 signal levels, which interface with most system architectures. For system architectures requiring RS-232C signal levels, Symbol offers different cables providing TTL-to-RS232C conversion. Contact the Symbol Support Center for more information. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

Note

*Baud Rate 57,600

Feature/Option

Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where the bar code can be seen clearly, and bars and/or spaces are not merging.

Page 88

7-4 DS6608 Product Reference Guide

Connecting an RS-232 Interface This connection is made directly from the digital scanner to the host computer.

Interface Cable

Serial Port Connector to Host

Power Supply Cable

Figure 7-1. RS-232 Direct Connection

Note

Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same.

1. Attach the modular connector of the RS-232 interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-4). 2. Connect the other end of the RS-232 interface cable to the serial port on the host. 3. Connect the power supply to the serial connector end of the RS-232 interface cable. Plug the power supply into an appropriate outlet. 4. Select the RS-232 host type by scanning the appropriate bar code from RS-232 Host Types on page 7-8. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter.

Page 89

RS-232 Interface 7-5

RS-232 Parameter Defaults Table 7-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the RS232 Host Parameters section beginning on page 7-6. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Note Table 7-1. RS-232 Host Default Table Parameter

Default

Page Number

RS-232 Host Parameters RS-232 Host Types

Standard

7-8

Baud Rate

9600

7-9

Parity Type

None

7-11

Stop Bit Select

1 Stop Bit

7-12

Data Bits

8-Bit

7-12

Check Receive Errors

Enable

7-13

Hardware Handshaking

None

7-14

Software Handshaking

None

7-16

Host Serial Response Time-out

2 Sec

7-17

RTS Line State

Low RTS

7-18

Beep on <BEL>

Disable

7-18

Intercharacter Delay

0 msec

7-19

Nixdorf Beep/LED Options

Normal Operation

7-20

Ignore Unknown Characters

Send Bar Code

7-20

Page 90

7-6 DS6608 Product Reference Guide

RS-232 Host Parameters Various RS-232 hosts are set up with their own parameter default settings (Table 7-2). Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed below.

Table 7-2. Terminal Specific RS-232 Parameter Transmit Code ID

Standard (Default)

ICL

Fujitsu

WincorNixdorf Mode A

Wincor-Nixdorf Mode B/OPOS/ JPOS

Olivetti

Omron

No

Yes

Yes

Yes

Yes

Yes

Yes

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/ Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

9600

9600

Parity

None

Even

None

Odd

Odd

Even

None

None

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

None

None

Software Handshaking

None

None

None

None

None

Ack/Nak

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Low

High

Low

Low

Low = No data to send

Low

High

None

None

None

None

None

STX (1003)

None

Data Transmission Format

Hardware Handshaking

RTS Line State Prefix

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes. **If Nixdorf Mode B is scanned without the digital scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the digital scanner.

Page 91

RS-232 Interface 7-7

RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of code ID characters listed in Table 7-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals.

Table 7-3. Terminal Specific Code ID Characters ICL

WincorNixdorf Mode B/ OPOS/JPOS

WincorNixdorf Mode A

Fujitsu

Olivetti

Omron

UPC-A

A

A

A

A

A

A

UPC-E

E

E

C

C

C

E

EAN-8/JAN-8

FF

FF

B

B

B

FF

EAN-13/JAN-13

F

F

A

A

A

F

Code 39

C <len>

None

M

M

M <len>

C <len>

Codabar

N <len>

None

N

N

N <len>

N <len>

Code 128

L <len>

None

K

K

K <len>

L <len>

I 2 of 5

I <len>

None

I

I

I <len>

I <len>

Code 93

None

None

L

L

L <len>

None

D 2 of 5

H <len>

None

H

H

H <len>

H <len>

UCC/EAN 128

L <len>

None

P

P

P <len>

L <len>

MSI

None

None

O

O

O <len>

None

Bookland EAN

F

F

A

A

A

F

Trioptic

None

None

None

None

None

None

Code 11

None

None

None

None

None

None

IATA

H<len>

None

H

H

None

None

Code 32

None

None

None

None

None

None

Page 92

7-8 DS6608 Product Reference Guide

RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes.

Standard RS-232

ICL RS-232

Wincor-Nixdorf RS-232 Mode A

Wincor-Nixdorf RS-232 Mode B

Olivetti ORS4500

Omron