Page 81

UIDChecker™ UID Mark Validation Error Messages

FIGURE 3–28. About Box

UIDChecker™ Application Details

3

UIDChecker™ UID Mark Validation Error Messages UIDChecker™ reports a description of the first error it encountered trying to decode the UID mark. This should help you debug your marking application. Table 3–1 is a list of potential errors generated and some suggestions for how to correct your failing UID mark.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

3-37

Page 82

Chapter

3

UIDChecker™ Application Details

TABLE 3–1. UII Error Codes

UII Error Code

Suggestion to Correct Problem

240 ERROR - CHARACTER

The current part number’s data element character is either missing or has wrong semantics

240 ERROR - TOO LONG

The current part number is too long

240 ERROR - TOO SHORT

The current part number is too short

30P ERROR - CHARACTER

The current part number’s data element character is either missing or has wrong semantics

30P ERROR - TOO LONG

The current part number is too long

30P ERROR - TOO SHORT

The current part number is too short

30T ERROR - CHARACTER

The lot/batch number’s data element character is either missing or has wrong semantics

30T ERROR - TOO LONG

The lot/batch number is too long

30T ERROR - TOO SHORT

The lot/batch number is too short

DATA ELEMENT CHARACTER

The data element character is either missing or wrong semantics

DATA ELEMENT SEPARATOR

The data element separator is either missing or wrong semantics

DATA ELEMENT TOO LONG

The data element character is too long

DATA ELEMENT TOO SHORT

The data element character is too short

DOUBLE TRAILER

Remove one trailer at the end

FORMAT INDICATOR ERROR

Correct the Format Indicator (05, 06, DD, or 12)

HEADER 1ST POSITION

Correct the error in the 1st position of the header; The Mark does not appear to be a UID Mark.

HEADER 2ND POSITION

Correct the error in the 2nd position of the header

HEADER 3RD POSITION

Correct the error in the 3rd position of the header

HEADER 4TH POSITION

Correct the error in the 4th position of the header

HEADER GROUP SEPARATOR

GS is needed right after the Format Indicator

LOWER CASE CHARACTER

A lower case character was found, replace with an Upper case character.

NEED UII ELEMENT FIRST

The UII element is not at beginning of the data elements

PNR ERROR - CHARACTER

The current part number’s data element character is either missing or has wrong semantics

3-38

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 83

UIDChecker™ Data Matrix Verification Error Messages

TABLE 3–1. UII Error Codes (continued)

UII Error Code

Suggestion to Correct Problem

PNR ERROR - TOO LONG

The current part number is too long

PNR ERROR - TOO SHORT

The current part number is too short

SPACE AFTER TEI DATA QUALIFIER

The TEI space is either missing or wrong semantics

TEI DATA CHARACTER

The TEI character is either missing or wrong semantics

TEI DATA QUALIFIER

The TEI data qualifier is either missing or wrong semantics

TRAILER - END OF TRANSMISSION

The trailer EOT is either missing or wrong syntax

TRAILER - RECORD SEPARATOR

The trailer RS is either missing or wrong syntax

UII ELEMENT INCOMPLETE

There is an incomplete UII element

UII STRING TOO LONG

The UII string is over 50-character limit

WRONG FORMAT INDICATOR

Correct the Format Indicator (05, 06, DD, or 12)

UIDChecker™ Data Matrix Verification Error Messages UIDChecker™ reports the following locate/decode, and verification error messages. TABLE 3–2. Data Matrix Locate/Decode Error Codes

Locate/Decode Error

Reason

No edge candidate found

Cannot find the any acceptable edges

First edge not found

Cannot determine the first border

Second edge not found

Cannot determine the second border

Third edge not found

Cannot determine the third border

Fourth edge not found

Cannot determine the fourth border

Four corners not found

Cannot determine all four corners

Size varying too much

Severe distortion causes size to vary too much

Row/Column test failed

Cannot determine rows or columns

Border match test failed

Border quality not acceptable

Unable to decode

Failed to decode the Data Matrix

Inspection timeout

Timed out in decoding Data Matrix v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

3-39

UIDChecker™ Application Details

3

Page 84

Chapter

3

UIDChecker™ Application Details

TABLE 3–3. Data Matrix Verification Error Codes

Verification Error

Reason

ISO Verification aperture too large

Data Matrix cell size is too small for the aperture 05 specified for ISO/IEC 15415

ISO Verification aperture too small

Data Matrix cell size is too large for the aperture 05 specified for ISO/IEC 15415

ISO Verification cell size greater than Max X

Cell size is greater than Max X specified for AIM DPM-1-2006.

ISO Verification cell size smaller than Min X

Cell size is smaller than Min X specified for AIM DPM-1-2006.

ISO Verification ECC200 required

ECC200 is required for ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification failed RDA error correction

Failed error correction in Reference Decode Algorithm in ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification failed RDA final image adjustment

Failed the final image adjustment step in AIM DPM-1-2006

ISO Verification failed RDA STEP A E

Failed Reference Decode Algorithm in steps A through E in ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification failed RDA STEP F 1

Failed Reference Decode Algorithm in step F 1 in ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification failed RDA STEP F 2

Failed Reference Decode Algorithm in step F 2 in ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification failed RDA STEP F 3

Failed Reference Decode Algorithm in step F 3 in ISO/IEC 15415 or AIM DPM-1-2006

ISO Verification insufficient space

There is insufficient space surrounding the Data Matrix for ISO/IEC 15415 or AIM DPM-1-2006.

3-40

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 85

4 UID Read Result Data Details

In this chapter, you will learn more about examining and managing your UID Read results. First, the on-screen data presentation will be explained, then the data log file will be explained. Refer to “View Results” starting on page 3-28 for an overview of the UID Mark Read Results.

Analyzing the Results of UIDChecker™ If the Data Matrix mark is a valid UID mark and is verified to be of good quality, then both the Validation and Verification panels at the right of the screen will become green, as shown in Figure 4–1. The light on top of the unit will also show green.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

4-1

4 UID Read Result Data Details

CHAPTER 4

Page 86

Chapter

4

UID Read Result Data Details

FIGURE 4–1. UIDChecker, Passed UII, Good Quality

4-2

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 87

Analyzing the Results of UIDChecker™

If either the validation or the verification test failed, the appropriate panel will be red, as shown in Figure 4–2. The light on top of the unit will also show red. FIGURE 4–2. UIDChecker, Passed UII, Bad Quality

UID Read Result Data Details

4

If the UID mark is valid, then the validation results panel reports the UID mark components. As long as the Data Matrix can be decoded and verified, the verification panel shows the grading on each of the quality tests. The v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

4-3

Page 88

Chapter

4

UID Read Result Data Details

UIDChecker™ provides an overall pass/fail using green/red background color based on the standard you select. For detailed descriptions of the Data Matrix Verification, please consult the HawkEye™ 1500 Series Verification Manual. Figure 4–3 through Figure 4–9 show various possible UII validation results. For each figure, the on-screen result is shown on the left and the corresponding UID Read Report is shown on the right. Figure 4–3 displays the results of a valid UII Data Matrix. Note that the Data Qualifier is available in the UID Read Report. FIGURE 4–3. Data Validation, Valid UII

Figure 4–4 displays the results of a valid PNR Data Matrix with the option “Enable CPN/LBN Support” enabled. FIGURE 4–4. Data Validation, Valid CPN/LBN

4-4

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 89

Analyzing the Results of UIDChecker™

Figure 4–5 displays the results of an invalid UII Data Matrix due to an 15434 error. FIGURE 4–5. Data Validation, 15434 Error in UID Validation

Figure 4–6 displays the results of an invalid UII Data Matrix due to a UII data element error.

Figure 4–7 displays the results of an invalid 240 Data Matrix with the option “Enable CPN/LBN Support” checked. FIGURE 4–7. Data Validation, CPN Error in UID Validation v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

4 UID Read Result Data Details

FIGURE 4–6. Data Validation, UII Error in UID Validation

4-5

Page 90

Chapter

4

UID Read Result Data Details

Figure 4–8 displays the result of validating a valid PNR Data Matrix without checking the “Enable CPN/LBN Support” option. FIGURE 4–8. Data Validation, UII Error for a Valid CPN

Figure 4–9 displays validation results of UII and 30P in the same Data Matrix when both UII and 30P are valid. Note that “Enable CPN/LBN Support” is checked. FIGURE 4–9. Data Validation of UII & 30P in a Single Data Matrix

UID Results Data File When a read result is saved, the UIDChecker™ software generates a unique number that gets incorporated into the name of the result and image files. This number is an 8 digit hexadecimal number starting at the number “00000000”. For each saved result, this number gets incremented by 1. The last number used gets stored in the system registry so that, when the UIDChecker™ application is launched again, the next number to be used can be retrieved from the system registry.

4-6

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008