Page 51

UIDChecker™ Buttons Overview

UIDChecker™ Buttons Overview Tool tips are available for each of the main buttons shown in Figure 3–2: FIGURE 3–2. UIDChecker™ Main Buttons

•

“Live Video” starting on page 3-7

•

“Read And Rotate” starting on page 3-8

•

“Read UID Mark” starting on page 3-8

•

“View Result” starting on page 3-9

•

“Print Result” starting on page 3-9

•

“Save Result” starting on page 3-9

UIDChecker™ Application Details

3

Live Video Use the Live Video button to position a mark in the FOV of the reader. Note that the Data Matrix must be completely within the screen for a successful read. For UID-LDP, the laser lines are at the middle of the FOV. Live Video is enabled once connected to a UID reader. Clicking Live Video displays the live video from a reader on the user interface. Clicking Live Video a second time stops the Live Video update. If Live Video is enabled, all other user interface buttons and drop down menus are disabled until the Live Video update is complete. When the Live Video update is complete, the result text display is cleared. When the verification type is set to MIL-STD-130M/Change 1 (AIM DPM-12006 for DPM) or MIL-STD-130N (AIM DPM-1-2006), Live Video can adjust automatically the exposure to obtain the proper contrast of the mark. In UIDDPM, Live Video can be used to display images for each supported light configuration.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

3-7

Page 52

Chapter

3

UIDChecker™ Application Details

For a secured UID verifier, LiveVideo displays the outline of the Data Matrix mark without the image itself. To improve the responsiveness of the live video, it is recommended that the Data Matrix be centered using fixtures.

Read And Rotate The Read And Rotate button is visible when you select the MIL-STD-130L Change 1 (ISO 15415) Verification Type. Refer to Appendix B, “Read And Rotate,” for details.

Read UID Mark After you click Read UID Mark, reading and decoding may take up to one second. Once the mark is read, the PC screen and the light will be updated to reflect the UID compliance and the mark quality verification status. Note: If the verification type is set to MIL-STD-130M Change 1 (AIM DPM-12006 for DPM) or MIL-STD-130N (AIM DPM-1-2006) with a report mode of Overall Grade For All Lights, a sequence of images are taken with different lights and will take longer than one second.

Note: F8 is the hotkey to read a mark; it simulates a mouse click on the Read button. Also, the Read button retains the focus of the application, so clicking the Enter button on the Keyboard will also begin a “Read”. The UIDChecker application must be in focus for these hotkeys to work.

Analyzing the Results of UID Compliance Check If the Data Matrix mark is a valid UID mark and is verified to be of good quality, then both the Validation and Verification panels at the right of the screen will become green. The light on top of the unit will also show green. If either the validation or the verification test failed, the appropriate panel will be red and the light on top of the unit will show red. If the UID mark is valid, then the validation results panel reports the UID mark components. As long as the Data Matrix can be decoded and verified, the verification panel shows the grading on each of the verification parameters corresponding to the verification type specified.

3-8

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 53

UIDChecker™ Buttons Overview

Results When a mark is decoded, extra buttons appear on the screen: View Results, Print Results and Save Results. A complete description of the Results can be found on “View Results” starting on page 3-28.

View Result

Note: The image will contain only the outline of the Data Matrix for a secured UID verifier.

Print Result Select Print Result to send the current UID Read report to the PC’s default printer. Print Result combines the last UID Mark read image, compliancy results, and the customer defined fields onto a one sheet 8½ x 11 inch printout. Then, you can specify your local or network printer. Note: The button is only enabled when the result text area of the screen contains data. These results contain a Microscan logo and uidsupport contact information. This logo may be replaced with a customer-selected bitmap of appropriate size. See “Define Customer Fields” on page 3-21.

Save Result Select Save Result to save the current UID Read results and the image to a file on the PC’s hard drive. This button is enabled if automatic logging of read results is OFF. Clicking Save Result appends the read results, including the name of the image file, to the data file. Note: The button is only enabled when the result text area of the screen contains data.

v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

3-9

3 UIDChecker™ Application Details

Select View Result to see the full UID Mark report including the image. This will transfer you to the results display. From here, you can manage your UII read results. This is fully explained in “View Results” starting on page 3-28.

Page 54

Chapter

3

UIDChecker™ Application Details

Main Menu Items The main menu items are: •

“File” starting on page 3-10

•

“Reader” starting on page 3-10

•

“Define Customer Fields” starting on page 3-21

•

“Results Setup” starting on page 3-22

•

“View Results” starting on page 3-28

•

“About” starting on page 3-36

File Exit This menu item exits the UIDChecker™ application. This button allows a graceful exit from the UIDChecker™ program. The laser and LEDs are shut off when the UIDChecker™ program is exited.

Reader Find a Reader This menu item launches an applet to show all the readers on the customer’s network. The customer needs to simply browse the display of readers and, with his mouse, select his reader from the list.

3-10

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 55

Main Menu Items

FIGURE 3–3. Drop Down List of Readers

If the reader cannot be found, select the Configure Camera Through Serial Port button to display the dialog box shown in Figure 3–4: FIGURE 3–4. Communications Configuration v2.3.1, Dec 2008

Getting Started With Your UID Compliance Verifier

3-11

UIDChecker™ Application Details

3

Page 56

Chapter

3

UIDChecker™ Application Details

With the serial cable plugged in to the PC’s COM port and the UID verifier, select the correct PC Serial Ports then click the Connect via Serial to display the screen displayed in Figure 3–5: FIGURE 3–5. Communications Configuration, After Successful Connection

Notes: The camera serial port in the UID verifier is configured at the factory with the setting: Baud Rate 115200, Parity None, Data Bits 8, Stop Bits 1, Flow Control None. The serial port setting for PC Serial Ports are locked to be the same as the camera and cannot be changed. If your PC has more than one serial port and you select the wrong serial port from PC Serial Port and click the Connect via Serial button, the software will take a long time to time out and fail to make the connection. When this happens, it is possible that you will not be able to connect the PC to the camera even though you then select the correct serial port. You need to click the Cancel button on each of the two dialogs and then exit UIDChecker. Restart UIDChecker, select the correct PC serial port, and click the Connect via Serial button again. To ensure Ethernet communication, you need to set either PC or the UID verifier such that both IP addresses are on the same subnet, have the same subnet mask and have different host names. In the above example, the UID verifier IP address is 192.168.1.47 and the PC IP address is 192.168.1.46.

3-12

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 57

Main Menu Items

Turn Laser Off When this menu item is clicked, the laser on the UID-LDP verifier can be turned off and the menu option will be re-captioned to be “Turn Laser On”. Clicking Turn Laser On will turn the laser on and re-caption this menu option to “Turn Laser Off”.

Warning DO NOT LOOK DIRECTLY AT THE BEAMS OF THE LASER!

Calibrate You MUST calibrate your UID-LDP and UID-DPM upon first time startup in your production area and, again, if you move the UID reader or the ambient light changes. The work environment where you will use your UID reader should be a stable environment in terms of lighting. For example, if you work in an office near windows, there might be read considerations when you perform a read at noontime on a sunny day versus a read performed during 3rd shift at 2AM on a moonless night. We suggest you position the UID reader in a fairly steady-state lighting environment where ambient light is consistent and at a low level. For certain verification types, such as AS9132 Dot Peen, where contrast is not read or reported, calibration is performed to simply relate pixel size to dimensional units. In this case, the camera should be calibrated normally using the supplied calibration target, and then photometry values may be changed to obtain good images with dark or reflective samples. The UID-LDP and UID-DPM comes with a Calibration Target (Microscan part number 98-UA10-0CC0). Once you have positioned your UID-LDP and UIDDPM into your work space, you need to re-calibrate the system using this Calibration Target. 1.

v2.3.1, Dec 2008

Position the Data Matrix (around 80% contrast) under the UID-LDP or UID-DPM.

Getting Started With Your UID Compliance Verifier

3-13

3 UIDChecker™ Application Details

Caution If the targeting lasers are activated, do not stare into the beams. The UID-LDP’s targeting lasers have been rated as Class II lasers by IEC 60825-1.

Page 58

Chapter

3

UIDChecker™ Application Details

2.

Click Reader -> Reflectance Calibrate to bring up the Calibration dialog box, as shown in Figure 3–6.

FIGURE 3–6. Calibration Dialog Box

3-14

–

Light Angle, Displays light configurations (or light angle) available to the connected UID verifier. For UID-LDP, only 90 is displayed.

–

Exposure Time, Displays exposure time for the HawkEye 1500 camera corresponding to each light configuration. These values are normalized at factory and will not change by the Reflectance Calibration.

–

Gain, Displays camera gain control value for the HawkEye 1500 camera corresponding to each light configuration. These values are normalized at factory and will not change by the Reflectance Calibration.

–

CellUnit, Displays how the verifier relates pixel values to inches for each light. All the values displayed should be the same or vary by no more than +/- 1.

–

ContrastMax/ContrastMin, These values are used to calibrated contrast value for all verification type except MIL-STD-130M/Change 1 (AIM DPM-1-2006 for DPM) or MIL-STD-130N (AIM DPM-12006). These are calibrated by the reflectance calibration.

–

R_cal, These values are calibrated for MIL-STD-130M/Change 1 (AIM DPM-1-2006 for DPM) or MIL-STD-130N (AIM DPM-1-2006) for reporting Minimum Reflectance.

–

Status, Displays the date and time when the reflectance calibration takes place. If unsuccessful, error messages are displayed here.

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008

Page 59

Main Menu Items

In the Cal. Target Contrast text box, enter the value associated with the Data Matrix (80% contrast) you are using as the target. For example, if the contrast marked for the Data Matrix on the Calibration Test Card is 82.6%, you would enter 82.6 or 83.

4.

In the Cal. Target Reflectance Max text box, enter the value associated with the Data Matrix (80% contrast) you are using as the target. For example, if the R_max marked for the Data Matrix on the Calibration Test Card is 87.4%, you would enter 87.4 or 87.

5.

The Live Video mode is enabled. Center the Data Matrix (about 80% contrast) on the Calibration card in the camera’s FOV.

FIGURE 3–7. Data Matrix Centered in FOV

6.

v2.3.1, Dec 2008

Click Calibrate.

Getting Started With Your UID Compliance Verifier

3 UIDChecker™ Application Details

3.

3-15

Page 60

Chapter

3

UIDChecker™ Application Details

The UIDChecker™ will calibrate the reader in less than 10 seconds or post error messages if it can’t. All calibration data are saved to the verifier. The top border of the UIDChecker™ application will show the last calibration date. Also, the calibration date will be posted in the Results display.

Lighting & Exposure FIGURE 3–8. Lighting & Exposure Adjustment Dialog Box

•

3-16

Select Light, In UID-DPM, for the MIL-STD-130M/Change 1 (AIM DPM-1-2006 for DPM) or MIL-STD-130N (AIM DPM-1-2006) verification types, all supported light configurations are displayed. You can select a light configuration and use it for live video display. For other verification types in UID-DPM, only light configuration 90 is displayed and enabled. For UID-LDP, only 90 is displayed.

Getting Started With Your UID Compliance Verifier v2.3.1, Dec 2008