Spec sheet · Siemens
Siemens NERLITE DOAL-50 and NERLITE DOAL-100 Spec Sheet
Spec sheet2 pagesPDF 258 KB
Both pages are below, each with its text.
Covers · 2 models
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page configuration guide from Microscan for the NERLITE DOAL Series illuminators, covering the DOAL-25, DOAL-50 V2, DOAL-75 and DOAL-100 in red, white, blue and infrared, continuous and strobe versions. It lists the part number of each version, which controller and power supply each one needs, and how to connect the leads. It helps a technician wire a DOAL light and set up its controller without damaging it.
- Device
- NERLITE DOAL Series illuminators in sizes DOAL-25, DOAL-50 V2, DOAL-75 and DOAL-100 p. 1
- Versions
- DOAL-50 V2, DOAL-75 and DOAL-100: red, white, blue or infrared, each in continuous or strobe p. 1
- Power, no controller
- 24VDC +/- 1% for lights that do not need a controller p. 2
- Controllers
- NL-200 Series lighting controller; legacy LC50 and LC100 series controllers p. 1, 2
- Controller supply
- LC50 and LC100 series: 24 to 40VDC; NL-2XX series: 24 to 48VDC p. 2
- Connector
- Flying lead cable with three, five or seven labeled leads, or a 4 pin male M12 connector p. 2
- M12 pinout
- Pin 1 positive (+), pin 3 negative (-), shell to chassis ground; pins 2 and 4 not used p. 2
- Strobe limits
- At maximum rated current: pulse width 1mS maximum, duty cycle 6% maximum p. 2
- DOAL-50 V2 part numbers
- Red continuous NER-011200814, red strobe NER-011200812, white continuous NER-011200824, white strobe NER-011200822 p. 1
- DOAL-50 V2 blue, infrared
- Blue continuous NER-011200834, blue strobe NER-011200832, infrared continuous NER-011200892, infrared strobe NER-011200897 p. 1
- DOAL-100 part numbers
- Red continuous NER-011200602, red strobe NER-011200601, white continuous NER-011204601, white strobe NER-011204600 p. 1
- DOAL-100 blue, infrared
- Blue continuous NER-011204610, blue strobe NER-011204611, infrared continuous NER-011200603, infrared strobe NER-011200605 p. 1
- Accessories
- AC power cords for the power supply in US, EU and UK versions p. 2
What this sheet walks you through
- Choosing the controller and power supply for each DOAL version p. 1
- Connecting flying lead models to a power supply or controller p. 2
- Wiring the separate fan circuit p. 2
- Wiring the M12 connector p. 2
- Setting the current on an NL-2XX controller for strobe mode p. 2
Good to know
- In strobe mode on an NL-2XX controller, set the current rating to 10% of the current on the light's label; a higher setting may damage the light. p. 2
- Models with a separate fan circuit must have 24VDC on the fan circuit at all times while the light is operating. p. 2
- The strobe limits of 1mS pulse width and 6% duty cycle apply at maximum rated current; the NL-2XX manual gives limits for other conditions. p. 2
Questions this sheet answers
What voltage does a NERLITE DOAL light need without a controller?
Lights that do not require a controller need 24VDC +/- 1%. p. 2
How do I set an NL-200 controller for a DOAL light in strobe mode?
Set the current rating to 10% of the current printed on the light's configuration label. The controller can drive up to 1000% of rated current in strobe mode, so a higher setting may damage the light. p. 2
What is the DOAL M12 connector pinout?
Pin 1 goes to the positive (+) output and pin 3 to the negative (-) output; the shell goes to chassis ground and pins 2 and 4 are not used. p. 2
What is the part number of the DOAL-100 white strobe light?
NER-011204600. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Nerlite DOAL Series Illuminators Configuration Guide
Continuous Current Strobe Current
Continuous OperationStrobe OperationControllerRequired NL-2XX
No (Select Any LC100-350 LC100-700 LC100-1050 Optional
Controller One of the (Legacy) (Legacy) (Legacy) (Used only if
Required Indicated (LC100 Used (LC100 Used (LC100 Used Intensity
(Can be LCXXX Only if Only If Only If And/Or
Connected (Legacy) or Intensity Intensity Intensity Ethernet Part Number Description Lighting Fan 40mA
Lighting Channel 1NER-011201305DOAL-25 Red ContinuousNER-011201314DOAL-25 Red StrobeNER-011201313
DOAL-25 White Continuous
NER-011200814
DOAL-50 V2 Red Continuous
NER-011200812DOAL-50 V2 Red StrobeNER-011200824
DOAL-50 V2 White Continuous
NER-011200822
DOAL-50 V2 White Strobe
NER-011200834
DOAL-50 V2 Blue Continuous
NER-011200832DOAL-50 V2 Blue StrobeNER-011200892
DOAL-50 V2 Infrared Continuous
NANANER-011200897
DOAL-50 V2 Infrared Strobe
NANA2.10A pk.NER-011200502DOAL-75 Red Continuous240mA62mANANER-011200501DOAL-75 Red Strobe4.80A pk.NER-011204902
DOAL-75 White Continuous
NER-011204901DOAL-75 White StrobeNER-011205720
DOAL-75 Blue Continuous
NER-011205721DOAL-75 Blue StrobeNER-011200506
DOAL-75 Infrared Continuous
NER-011200507
DOAL-75 Infrared Strobe
NER-011200602
DOAL-100 Red Continuous
NER-011200601DOAL-100 Red StrobeNER-011204601
DOAL-100 White Continuous
NER-011204600DOAL-100 White StrobeNER-011204610
DOAL-100 Blue Continuous
NER-011204611DOAL-100 Blue StrobeNER-011200603
DOAL-100 Infrared Continuous
NER-011200605
DOAL-100 Infrared Strobe
Lighting Channel 2Fan CooledLC50-700 (Legacy)LC50-1050 (Legacy)LC50-1400 (Legacy)LC50-2100 (Legacy)Control is Desired)Control is Desired)Control is Desired)NL-2XX Required)NANA0.80A pk.64mANANANAFigure AFigure B200mANANANAFigure AFigure BNANA4.00A pk.200mANANANANA4.00A pk.NANANANA4.00A pk.100mANANA480mA62mANANANA9.41A pk.480mA62mANANANA9.41A pk.240mA62mANANANA5.04A pk.427mA62mANANANA8.40A pk.823mA62mANANANA8.62A pk.823mA62mANANANA8.62A pk.418mA62mANANANA8.82A pk.Figure AControl Is Desired)NA200mANA
Directly to NL2XX Series LC50-350 24VDC) Controllers (Legacy)
NANA Figure A Figure ANAFigure A Figure AXFigure AXFigure AXFigure AXFigure AXFigure AXFigure AXFigure AFigure B Figure BFigure C7.84A pk. NAFigure BFigure C7.84A pk. NAFigure BFigure CNA NAFigure BFigure CNA NAFigure BFigure CNA NAFigure BFigure CNA NAFigure BFigure CNA NAFigure BFigure BNA XFigure BFigure BNANAFigure BFigure BNA NAback of page)Figure BNANA
Connection Notes Reference Number (See the Connection Notes on
Figure BFigure CNAFigure B
1 1 1 1 1 1 1 1 1 1 1 2 1 2 1 2 1 2 1 2 1 2 3 2 3 2 1
Hardware Required 12Item 1 2 3
Description DOAL Series Illuminators Power Supply DSP60 24VDC 2.5A DIN Mount NL-200 Series Lighting Controller
Part Number NER-01120XXXX NER-011504100 98-000152-0X
Figure A DOAL Series Illuminator with power supply
321- POWER + INPUT1
- 12V. 1.4A (UNFUSED)
- POWER OUTPUT
- POWER
- INPUT
- 12V. 1.4A (UNFUSED)
- POWER OUTPUT
2
3
Fan Leads Figure B DOAL Series Illuminator with NL-200 Controller and power supply
Copyright ©2010 Microscan Systems, Inc.
Figure C DOAL Series Illuminator with NL-200 Controller, power supply And fan circuit
Lighting Leads
P/N 83-230004 Rev A
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
NERLITE DOAL Series Illuminators
Accessories AC Power Cord US AC Power Cord EU AC Power Cord UK
NER-030028300 NER-030028400 NER-030028500
Power Cord For Power Supply Power Cord For Power Supply Power Cord For Power Supply
General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The LC50 and LC100 series controllers require 24 to 40VDC. 3. The NL-2XX series controllers require 24 to 48VDC. 4. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 5. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions. 6. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 7. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. 8 ATTENTION! When programing an NL-2XX series controller for use in strobe mode, you must set the current rating to 10% of the current printed on the configuration label on the light. The NL-2XX Series Controller allows the operator to set the output to 1000% of the rated current in strobe mode. By programming the initial current rating at 10% of the light’s rated current, full intensity is achieved and the controller is prevented from exceeding the light’s rated current. Setting the current rating at a value greater than 10% of the current printed on the configuration label on the light may result in damage to the light. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the two leads labeled “V+1” & “V+2” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “GND1” & “GND2” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.
Copyright ©2010 Microscan Systems, Inc.
www.microscan.com