Spec sheet · Sick
Sick WTB140 Spec Sheet
Spec sheet2 pagesPDF 223 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
This is a two-page Sick data sheet for the WTB140 photoelectric proximity switch, a red-light DC sensor with background suppression, in NPN and PNP versions. It gives the dimensions and adjustments, connection diagrams, technical specifications, a scanning range chart and the type list for ordering.
- Device
- Photoelectric proximity switch with background suppression (BGS), red light, DC p. 1
- Scanning distance
- 2 ... 500 mm typical maximum; operating distance 15 ... 500 mm p. 2
- Supply voltage
- DC 10 ... 30 V; 30 mA or less without load p. 2
- Switching output
- NPN or PNP open collector, 100 mA maximum output current p. 2
- Connection
- PVC cable 2 m, M8 3-pin connector or M8 4-pin connector p. 2
- Light source
- LED, red light, 680 nm; light spot approx. 15 mm at 200 mm p. 2
- Response time
- 0.5 ms or less; switching frequency 1,000 Hz p. 2
- Distance adjustment
- Potentiometer, 5 revolutions p. 2
- Light/dark switching
- Via L/D control cable or via rotary switch p. 2
- Off delay
- Optional, selectable 0 ... 100 ms p. 1, 2
- Enclosure rating
- IP 67 p. 2
- Operating temperature
- -25 °C ... +55 °C; storage -40 °C ... +70 °C p. 2
- Housing material
- PBT, PC p. 2
What this sheet walks you through
- Dimensions, mounting holes and adjustment controls p. 1
- Connection diagrams for the cable and M8 connector versions p. 1
- Scanning range on black, gray and white objects p. 2
- Ordering information by type p. 2
Good to know
- Scanning distances are for an object with 90% remission, with the scanning distance control set to MAX. p. 2
- The cable must not be bent below 0 °C. p. 2
- The supply voltage is given for operation in a short-circuit protected network of max. 8 A. p. 2
Questions this sheet answers
What is the scanning distance of the Sick WTB140?
The data sheet gives a typical maximum scanning distance of 2 to 500 mm, adjustable with a 5-turn potentiometer. p. 2
What supply voltage does the WTB140 need?
It runs on DC 10 to 30 V and draws 30 mA or less without load. p. 2
What connectors are available on the WTB140?
The sheet lists a 2 m PVC cable, an M8 3-pin connector and an M8 4-pin connector. p. 2
Is the WTB140 output NPN or PNP?
The sheet lists versions with an NPN open collector output and versions with a PNP open collector output, rated 100 mA. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
DB_W140_2_en.fm Seite 2 Dienstag, 31. Januar 2006 3:52 15
Photoelectric proximity switch, WTB140, BGS, red light - DC Dimensional drawing
20
Optionally with off delay tOFF = 0 ... 100 ms
8.6 17.725.4 23321410.8
Scanning distance adjustable via potentiometer Red light as alignment aid
15Adjustments possible1
Mounting hole Ø 3.2 mm for M3
2
Standard direction of the material to be scanned
3
Optics center, receiver
4
Optics center, transmitter
5Connector6
Green LED indicator:light reception with
7
operating reserve >1.1 Orange LED indicator: switching output active
8
Scanning distance control (5 turns)
9
- Light/dark rotary switch
- 2.7
With background suppression (BGS), consequently reliable detection of dark objects in front of a light background
11
3
Photoelectric proximity switch
31
Scanning distance 2 ... 500 mm
2.5 1
8
WTB140-N122 WTB140-N420 WTB140-P122 WTB140-P420
WTB140-N132 WTB140-N330 WTB140-N430 WTB140-P132 WTB140-P330 WTB140-P430
678 SENS.67SENS.8
L = light switching, D = dark switching 10 OFD, selector switch (270 °) off delay t OFF ; t =0 s (OFF)...0.1 s
OFD9LD00.1S10Connection type
Accessories Connector, M8, 3-pin Connector, M8, 4-pin Mounting systems
2SICKWTB140-N330WTB140-N420WTB140-N122WTB140-N132WTB140-N430WTB140-P330WTB140-P420WTB140-P122WTB140-P132WTB140-P430M8, 3-pinM8, 4-pin4 x 0.18 mm²3 x 0.18 mm²M8, 4-pinbrn1blu3blk4brn1Mblu3Qblk4wht2L+L+ M Q L/DL+brnL+brn1bluMbluMblu3blkQblkQblk4whtL/Dwht2brn09-01-2006L+ M Q NC
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
DB_W140_2_en.fm Seite 3 Dienstag, 31. Januar 2006 3:52 15
W140-2 Technical specifications
WTB140-
Scanning distance typ. max.
2 ... 500 mm1)Operating distance15 ... 500 mm1)
Adjustment of operating distance
Potentiometer, 5 revolutions
Light source, light type
LED, Red light, 680 nm2)
Light spot diameter Angle of dispersion
Approx. 15 mm at 200 mm distance Ca. 4.3 °
Supply voltage VsDC 10 ... 30 V3)Ripple± 10 %4)Power consumption≤ 30 mA5)Switching outputsNPN: open collector: QSwitching mode
Light-/dark-switching via L/D control cable
N122 N132 N330 N420 N430 P122
P132P330P420P430
PNP: open collector: Q Light-/dark-switching via rotary switch Signal voltage PNP HIGH / LOW
Vs - 1.8 V / approx. 0 V
Signal voltage NPN HIGH / LOW
Approx. Vs / < 1.8 VOutput current Iamax100 mAResponse time≤ 0.5 ms6)Switching frequency1,000 Hz7)Time delay
Selectable: 0 ... 100 ms
Time type Connection type
t OFF (off delay ) Cable, PVC, 2 m8) Connector, M8, 3-pin Connector, M8, 4-pin 9)
VDE protection class Circuit protection
Enclosure rating
Vs connections reverse-polarity protected / In-/outputs short-circuit protected / Interference suppression / Outputs overcurrent and short-circuit protected IP 67
Ambient temperature operation
-25 °C ... +55 °C
Ambient temperature storage
-40 °C ... +70 °CWeightCa. 53 g Ca. 9 gHousing materialPBT, PC1)
Object with 90% remission (based on standard white to DIN 5033). Scanning distance control set to MAX 2) Average service life 100,000 h at
Vs tolerances
Ta = +25°C Limit values, operation in short-circuit protected network max. 8 A 4) May not exceed or fall short of 3)
5) Without load 6) Signal transit time with resistive load 7)
8) Do not bend below 0 °C 9)
Reference voltage 50 V DC
With light/dark ratio 1:1
Sanning distance1152153150 (mm)30250 350 500100200300400
Ordering information Type Order No.
WTB140 BGB6%/90% 12518 %/90%500220
1 Scanning range on black, 6 % remission 2 Scanning range on gray, 18 % remission 3 Scanning range on white, 90 % remission
% of the scanning distance
Operating range15 90%/90% 103
6 012 628 6 012 636 6 012 638
WTB140-N420 WTB140-N430 WTB140-P122 WTB140-P132 WTB140-P330 WTB140-P420 WTB140-P430
6 012 631 6 012 639 6 012 632 6 012 640 6 012 642 6 012 635 6 012 643
50 (mm)09-01-2006
WTB140-N122 WTB140-N132 WTB140-N330
100200300400500S ICK3