Spec sheet · Sick
Sick WTA24 Spec Sheet
Spec sheet4 pagesPDF 322 KB
All 4 pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Pages from the SICK SENSICK catalogue on the WTA 24, a photoelectric proximity switch that measures distance and detects objects in one device. They describe applications, the dimensional drawing and controls, the 5-pin M 12 connection, how to teach the two switching outputs, and technical data with measurement ranges and accuracy for the WTA 24-P versions.
- What it is
- Photoelectric proximity switch for non-contact distance measurement and object detection, using the triangulation principle p. 1
- Scanning distance
- 100 to 3,000 mm across three versions p. 1
- Outputs
- Analogue 4 . . . 20 mA output plus two switching outputs Q1 and Q2, PNP, reversible p. 3, 4
- Supply
- 12 . . . 30 V DC p. 4
- Connection
- Rotatable 5-pin M 12 plug p. 3
- Light source
- LED, infrared light; average service life 100,000 h at +25 °C p. 4
- Switching setup
- Both switching outputs set by teach-in, with Q1/Q2 and Q/Q program switches p. 3
- Temperature
- Operation –10 °C to +55 °C; storage –25 °C to +75 °C p. 4
- Enclosure rating
- IP 67 p. 4
- Circuit protection
- Supply connections reverse-polarity protected, Q1 and Q2 short-circuit protected, interference pulse suppression p. 4
- Analogue capture range
- Outputs 3 or 21 mA when the object is in the capture range p. 4
- Housing
- Compact metal housing with M 5 threaded mounting holes p. 1, 3
- Applications
- Profile measurement, coil diameter detection, level monitoring, positioning in warehousing and handling p. 1
What this sheet walks you through
- Teaching the switching outputs p. 3
- Dimensional drawing and controls p. 3
- Wiring the 5-pin M 12 connection p. 3
- Measurement range, reproducibility and accuracy by version p. 4
Good to know
- Reproducibility and accuracy figures assume a 100 x 100 mm object and constant surroundings. p. 4
Questions this sheet answers
What outputs does the SICK WTA 24 have?
An analogue 4 . . . 20 mA output and two PNP switching outputs, Q1 and Q2. p. 3, 4
What distance range does the WTA 24 cover?
The three versions together cover scanning distances from 100 to 3,000 mm. p. 1
How do I set the switching points on a WTA 24?
Pick the output with the Q1/Q2 switch, place the object at the wanted distance and press the Teach-in key; the OK indicator lights when it is saved. p. 3
What supply voltage does the WTA 24 need?
12 . . . 30 V DC. p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
WTA 24 Distance sensors
Distance sensors
WTA 24: Distance measurement and object detection in one device The WTA 24 with its compact metal housing is immune to impacts, vibrations and other disturbances. This and numerous other features make this device suitable for a large number of applications such as profile measurement, the detection of coil diameters, level monitoring, for positioning tasks in warehousing and handling systems and min./max. regulation with
N
Non-contact distance measurement and object detection – the
WTA 24 photoelectric proximity switch combines both these functions. The sensor, available in three versions, covers scanning distances ranging from 100 to 3,000 mm. The triangulation principle is used to detect the presence and position of an object. The presence of an object is signalled via the digital device outputs; continuous distance values are further processed by means of the analogue interface.
446
SENSICK CATALOGUE
combined switching points.
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
WTA 24 m On circular cross-
cut saws, the width is measured continuously while the boards are automatically advanced. WTA 24 sensors see to this reliably.
n On circular cross-
cut saws, the width is measured continuously while the boards are automatically advanced.
m In continuous tyre production, supply
loops regulate web tension and, therefore, the tensile force in the material. The WTA 24 ensures that the loops are fed evenly.
SENSICK CATALOGUE
447
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
WTA 24 Photoelectric proximity switches with analogue output Dimensional drawing
Photoelectric proximity switches
- Analogue + digital output
107 14 17.56.514
Scanning distance 100 . . . 3000 mm
3■ High resolution24
- Switching outputs adjustable
α51M5 84.76256288
using simple teach-in
- Compact housing
- Insensitive to ambient light
9 302765Adjustments possible1All types2 3 4 5 6 7 8Teach inQ11 21 0 Q2 OKQ1 31 1 Q9 1 1 1 10 1 2 311.8
Standard direction of object being scanned Output Q2 function indicator Alignment sight Output Q1 function indicator Centre of transmitter’s optical axis Centre of receiver’s optical axis M 5 threaded mounting hole, 6 mm deep M 5 threaded mounting hole Rotatable plug ”Teach- in” programming switch ”Teach- in” function indicator ”Q1/Q2” program switch ”Q/Q” program switch
Adjustment instructions
C V
Connection type All types
Accessories Cable receptacles Mounting brackets
page 496 510
Cooling plates Weather covers
556 556448SENSICK CATALOGUE5-pin, M 12 brn1blK4blu3wht2gra5L+ Q1 M Q2 QA
Programming the switching outputs: 1. Move ”Q1/Q2” switch to the _ switching output to be programmed. Move ”Q/Q ” switch to the desired switching mode. 2. Place object at the required switching distance. 3. Press ”Teach- in” key. ”OK” indicator illuminates when the switching limit has been saved to the memory. 4. Repeat steps 1/2/3 for the second switching output. 5. The device is ready for operation.
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
WTA 24 Technical Data
WTA 24-P
Light source 1), light type
LED, infrared light
Supply voltage VS Ripple Current consumption
12 . . . 30 V DC 2) < 5 VSS3) < 100 mA 4)
Switching outputs Q1, Q 2 Output voltage Output current lA max. Response time 5) Max. switching frequency 6) Response time 5) Max. switching frequency 6) Response time 5) Max. switching frequency 6)
PNP, reversible HIGH = VS – < 2 V/LOW = < 2 V 100 mA 5 ms 100 Hz 50 ms 10 Hz 100 ms 5 Hz
Analogue output 7) 8)4 . . . 20 mAConnection typePlug
VDE protection class 9) Circuit protection 10) Enclosure rating
V
Ambient temperature TA 8)
Operation – 10 °C . . . + 55 °C Storage – 25 °C . . . + 75 °C To IEC 68 0.2 % / K
5201 5401 5501 5201 S 04
A, B, C IP 67
Shock load Temperature drift (relative to measured value) 1) Average service life 100,000 h at TA = + 25 °C 2) Limit values 3) May not exceed or fall short of VS tolerances
4) Without load 5) Signal transit time with resistive load 6) Object 50: 50 7) In capture range 3 or 21 mA 8) R = 0 . . . 500 Ω 9) Reference voltage 50 V DC
10) A = VS connections reverse-polarity protected B = Inputs Q1 and Q2 short-circuit protected C = Interference pulse suppression
Measurement range, reproducibility and accuracy WTA 24Measurement range Capture range Light spot diameter (90 % core light) Angle of dispersion α Reproducibility (relative to measured value, object 100 x 100 mm, ambient surroundings remain constant) Accuracy (relative to measured value, object 100 x 100 mm, ambient surroundings remain constant)
P 5201 250 . . . 350 mm 200 . . . 250 mm 4 . . . 8 mm
P 5201 S04 100 . . . 500 mm 80 . . .100 mm 8 . . .12 mm 7° White (90 %) Black (6 %)
1.0 % 1.0 % 1.5 %
2° White (90 %) Grey (18 %) Black (6 %)1)
1.5 % 2.5 % 4.0 %
0.5° White (90 %) Grey (18 %) Black (6 %)2)
4.0 % 10.0 % 8.0 %
blanc (90 %) Grey (18 %) Black (6 %)
1.5 % 2.0 % 4.0 %
blanc (90 %) Grey (18 %) Black (6 %)1)
3.0 % 5.0 % 8.0 %
blanc (90 %) Grey (18 %) Black (6 %)2)
5.5 % 13.0 % 10.0 %
1.0 % 2.0 %
White (90 %) 6.5 % Grey (18 %) 10.5 % Black (6 %) 11.5 %
Measurement rangeCapture rangeOrder informationCapture range4
P 5501 1000 . . . 3000 mm 500 . . .1000 mm 20 . . . 50 mm
7° White (90 %) Grey (18 %) Black (6 %)
1) up to 1000 mm 2) up to 2000 mm
QA (mA) 20
P 5401 600 . . .1200 mm 400 . . . 600 mm 15 . . . 30 mm
3 mA4...20 mA21 mA
Type WTA 24-P 5201 WTA 24-P 5401
Part no. 1 011 504 1 011 505
WTA 24-P 5501 WTA 24-P 5201 S04
1 011 515 1 015 804mm SENSICK CATALOGUE449