Spec sheet · Sick
W 30 Photoelectric proximity switches
Spec sheet8 pagesPDF 729 KB
Catalog pages for the WT 30 and WT 32 photoelectric proximity switches: infrared sensors with drawings, technical data and part numbers.
Covers · 1 model
The models it covers
Summary
What is in it
Pages from the SENSICK catalog on the W 30 family of photoelectric proximity switches. The WT 30 has background suppression with fixed scanning distances of 100, 200 and 305 mm, and the energetic WT 32 has an adjustable range of 100 to 2000 mm in DC and UC versions. For each it gives application examples, dimensional drawings, adjustments, connection diagrams, technical data (supply voltage, outputs, time delay, response time, enclosure rating, temperatures) and order part numbers.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
SICK catalog pages on W 30 photoelectric proximity switches: the WT 30 with background suppression (types WT 30-01 to WT 30-22) and the energetic WT 32, in DC types WT 32-B 230, WT 32-B 330, WT 32-B 430 and the UC type WT 32-R 230. They give application examples, dimensional drawings, adjustments, terminal connections and technical data.
- Device
- WT 30: photoelectric proximity switch with background suppression, infrared light, DC p. 3
- Types
- WT 30-01, WT 30-02, WT 30-11, WT 30-12, WT 30-21, WT 30-22 p. 3
- Switching outputs
- WT 30: PNP QP and NPN QN; PNP or NPN QR with current limiting (jumper QP to QN) p. 4
- Terminals
- WT 30: PG 9 entry; terminals 1 L+, 2 M, 3 QR, 4 QP, 5 QN p. 3
- Time delay
- WT 30: 0.04 to 12 s, ON-delay with jumper t1 or OFF-delay with jumper t2 p. 3
- Ambient temperature
- WT 30: operation -25 °C to +55 °C; storage -40 °C to +80 °C p. 4
- Light/dark switching
- WT 30: selected via jumper (a light-switching, b dark-switching) p. 3
- Enclosure
- WT 30: robust housing, IP 67 p. 1
- Indicators
- WT 30: power indicator and alignment sight p. 3
- WT 32
- WT 32: energetic proximity switch, infrared, scanning distance 100 to 2000 mm adjustable p. 5, 6
- WT 32 time control
- WT 32 DC types: 0.02 to 1 s; WT 32-R 230: 0.5 to 12 s p. 5, 7
- WT 32-R 230
- WT 32-R 230: UC type with terminal chamber, part number 1 007 413 p. 7, 8
What this sheet walks you through
- Choosing light- or dark-switching with a jumper p. 3
- Setting an ON- or OFF-delay with jumpers t1 and t2 p. 3
- Wiring the WT 30 terminal chamber p. 3
- Application examples: punching machine, windscreen positioning, six-packs and pallets p. 2
- WT 32 energetic switches in DC and UC versions p. 5, 7
Good to know
- WT 32-R 230: provide suitable spark suppression for inductive or capacitive loads. p. 8
Questions this sheet answers
What is the difference between the SICK WT 30 and WT 32?
The WT 30 uses background suppression with fixed scanning distances; the WT 32 is an energetic switch with an adjustable 100 to 2000 mm scanning distance. p. 1, 3, 5, 6
How do I set a time delay on the WT 30?
Connect jumper t1 for an ON-delay or jumper t2 for an OFF-delay; the delay range is 0.04 to 12 s. p. 3
How is the WT 30 wired?
Through a PG 9 entry to terminals 1 L+, 2 M, 3 QR, 4 QP and 5 QN. p. 3
What is the operating temperature of the WT 30?
-25 °C to +55 °C in operation; storage is -40 °C to +80 °C. p. 4
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file