Page 21
W12-2 WL12-2
Scanning range typ. max.
0 ... 4 m
Scanning range, recommended
0 ... 3.5 m
Relating to
Reflector PL80A
Sensitivity adjustment
Potentiometer
Light source, light type
LED, Red light1)
Light spot diameter
30 mm at 1.5 m distance
Angle of dispersion
Ca. 1.5 °
B560 P460
Polarisation filter Supply voltage Vs
DC 10 ... 30 V2)
Ripple
≤ 5 Vss3)
Power consumption
≤ 30 mA4)
Switching outputs
Transistor outputs Qp and Qn
Switching mode
Light-/dark-switching, switchable5)
PNP antivalent Output current Iamax
100 mA
Response time
≤ 330 µs6)
Switching frequency
1,500 Hz7)
Connection type
Connector, M12, 5-pin Connector, M12, 4-pin 8)
VDE protection class Circuit protection Enclosure rating
Vs connections reverse-polarity protected / Output QP and QN short-circuit protected / Interference suppression IP 69K
Ambient temperature operation
-40 °C ... +60 °C
Ambient temperature storage
-40 °C ... +75 °C
Weight
Ca. 120 g
Housing material
Zinc die-cast9)
1)
Average service life 100,000 h at Ta = +25 °C 2) Limit values 3) May not exceed or fall short of
9)
Vs = dark-switching
Vs tolerances
4) Without load 5) Control cable 0 V or open-circuited =
6) Signal transit time with resistive load 7) With light/dark ratio 1:1 8)
Teflon-coated housing available on request
Reference voltage 50 V DC light-switching. Control cable
Scanning range and operating reserve
1 0
3.5
2 0
1.8
3 0
1.6 1
3
3.5 3
1
2
10
7 0.5 0.8
21
0 (m)
1
2
3
4
■
Operating range
■
Scanning range, max. typical
Reflector type
Operating range
1 2
PL 80 A C 110
0 ... 3.5 m 0 ... 1.8 m
3 4
PL 50 A PL 40 A
0 ... 2.0 m 0 ... 1.8 m
5 6 7
PL 30 A PL 20 A
0 ... 1.6 m 0 ... 1.0 m
Reflective tape
0 ... 0.5 m
SICK
5
5 Operating reserve
6
3.5
1.8
5 0 0
3
2.0
4 0
100
4
Operating range
1
Scanning range typ.max. (m)
1
2
3
4
5
Ordering information Model Name Part Number WL12-2B560 WL12-2P460
1 016 080 1 016 105
13. 10. 2006
Page 22
Through-beam photoelectric switch, WS/WS12-2, red light - DC Dimensional drawing
24
10 3
Through-beam photoelectric switch
Red light; consequently, fast alignment is possible 1
22.6 2
7.3 5.6
2 16.5
M12 plug rotatable by 90°, or 2 m cable Adjustable sensitivity; optimum adaptation to application
5.1
32
Insensitive to external light sources, i.e., increased operating reliability
41.5 1
49
Scanning range 0 ... 20 m
4
15
5
11.2 Adjustments possible
1
1
LED signal strength indicator
2
Centre of optical axis
3
M4 threaded mounting hole - 4 mm deep
4
Mounting holes Ø 4.2 mm
5
Sensitivity adjustment
5 Sensitivity
Connection type WS/WE12-2N130 WS/WE12-2P130
See Accessories chapter Connector, M12, 4-pin Masks Mounting systems
WS/WE12-2N430 WS/WE12-2P430
4 x 0.25 mm²
M12, 4-pin
Sender brn
Receiver
L+ brn blu
M blk blk
TE wht blu
13. 10. 2006
Sender
Receiver brn
1
Q blu
3
Q blk
4
L+
M
L+ brn
1
M blk
4
TE wht
2 blu
3
L+ Q Q M
SICK
22
Page 23
W12-2 WS/WE12-2
Scanning range typ. max.
N130 N430 P130
P430
0 ... 20 m
Scanning range, recommended
0 ... 15 m
Sensitivity adjustment
Potentiometer
Light source, light type
LED, Red light1)
Light spot diameter
Approx. 500 mm at 15 m distance
Angle of dispersion
1.5 °
Supply voltage Vs
DC 10 ... 30 V2)
Ripple
≤ 5 Vss3)
Power consumption, sender
≤ 30 mA4)
Power consumption, receiver
≤ 25 mA4) ≤ 15 mA4)
Switching outputs
NPN antivalent PNP antivalent
Output current Iamax
100 mA
Response time
≤ 330 µs5)
Switching frequency
1,500 Hz6)
Test input sender off
TE to 0 V
Connection type
Cable, 2 m7) Connector, M12, 4-pin 8)
VDE protection class Circuit protection Enclosure rating
Vs connections reverse-polarity protected / Output Q and Q not short-circuit protected / Interference suppression IP 69K
Ambient temperature operation
-40 °C ... +60 °C
Ambient temperature storage
-40 °C ... +75 °C
Weight
Ca. 200 g Ca. 120 g
Housing material
Zinc die-cast9)
1)
3)
Average service life 100,000 h at Ta = +25 °C 2) Limit values
May not exceed or fall short of Vs tolerances 4) Without load
5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C
8) Reference voltage 50 V DC 9) Teflon-coated housing available on request
Scanning range and operating reserve
0
15
20
1000 0 (m)
4
6
8
■ Operating range
10
12 14 16 18 20
■ Scanning range, max. typical
Operating reserve
100
10 Operating range Scanning range, typ. max. 1 (m) 2 4 6 8 10
12
14
16
18 20
Ordering information Model Name Part Number
23
SICK
WS/WE12-2N130 WS/WE12-2N430
1 016 154 1 016 155
WS/WE12-2P130
1 016 156
WS/WE12-2P430
1 016 157
13. 10. 2006
Page 24
Proximity switch with fibre optic cables, WLL12, fibre-optic cable - DC Scanning distance 0 ... 280 mm
Dimensional drawing
24.5
10
Scanning range 0 ... 300 mm Proximity switch with fibre optic cables
53
Plug-in fibre-optic cables Switch-selectable light-/dark-switching Adjustable sensitivity
AD adapter* for
4.4
15
43
Fibre-optic Model NamePart Number
2
LL 3 - ...
1
AD-LL-1M0 2 015 026
Ø (1.0 mm)
49
4
29.5
Red, infrared or green light
3
LL 3 - ...
AD-LL-2M2 2 015 210
Ø (2.2 mm)
16.5
2
LM/LT- ...
5
AD-LL-GF
LH10-1000 AD-LL-HGA
2 015 034 2 015 033
* not included with delivery
40 6 13 Adjustments possible
6
1
Connector for fibre-optic cable
2
Sensitivity control
3
M4 threaded mounting hole - 4 mm deep
4
Adapter
5
Plug not rotatable. Plug facing backwards on request
5
LED signal strength indicator
Sensitivity
2
Connection type WLL12-B5181 WLL12-B5281 WLL12-B5381 WLL12-B5481
See Accessories chapter Adapter for fibre-optic cables Connector, M12, 5-pin Fibre-optic cables Mounting systems
13. 10. 2006
M12, 5-pin brn
1 blu
3 blk
4 wht
2 gra
5
L+ M QP QN L/D
SICK
24
Page 25
W12-2 WLL12-B
5181 5281 5381 5481
0 ... 280 mm1)
Scanning distance typ. max.
0 ... 60 mm1) Fibre-optic cable (proximity system)
LM/LT
Scanning range typ. max.
0 ... 200 mm 0 ... 300 mm 0 ... 20 mm
Fibre-optic cable (through-beam system) LM/LT LED, Red light2)
Light source, light type
LED, Infrared light2) LED, Green light2) Supply voltage Vs
DC 10 ... 30 V3)
Ripple
≤ 5 Vss4)
Power consumption
≤ 35 mA5)
Switching outputs
PNP: Q/NPN: Q
Switching mode
Light-/dark-switching, switchable
Output current Iamax
100 mA
Response time
360 µs6)
Switching frequency
1,300 Hz7)
Connection type
Connector, M12, 5-pin 8)
VDE protection class Circuit protection Enclosure rating
Vs connections reverse-polarity protected / Output Q and Q not short-circuit protected / Interference suppression IP 67
Ambient temperature operation
-25 °C ... +60 °C
Ambient temperature storage
-25 °C ... +70 °C
Weight
Ca. 130 g
Housing material
Zinc die-cast
1)
Object with 90 % remission (based on standard white to DIN 5033) 2) Average service life 100,000 h at Ta = +25 °C
Vs tolerances
3) Limit values 4) May not exceed or fall short of
5) Without load 6) Signal transit time with resistive load
7) With light/dark ratio 1:1 8)
Reference voltage 50 V DC
Proximity system with background suppression, WLL12-B5481 with LH10-1000 fibre-optic cable 1000
24
LH10/90
Adapter AD-LL-HGA
10
Standard direction of sensor
ø10
LH10-1000/..
16
Imprint
10.5
28
Scanning distance: Light spot diameter:
10 mm (- 1 mm), fixed approx. 2.5 x 3.5 mm
Switching hysteresis:
≤ 0.3 mm, based on standard white 90 % to standard black 6 %
Ordering information Model Name Part Number
25
SICK
WLL12-B5181
1 011 677
WLL12-B5281 WLL12-B5381 WLL12-B5481
1 011 687 1 011 688 1 011 965
13. 10. 2006
Page 26
LL3 Plastic fibre-optic cable Befestigungstechnik Fibre-optic cable Proximity System
Features
■ Highly flexible ■ Small bend radii ■ Most fibre-optic cables can easily be cut to length using cutter FC8) (supplied) ■ Operating temperature -- 40 … +70 °C, special designs up to 180 °C
Selection table: sensors, fibre-optic cables, scanning ranges Proximity Systems
Scanning distance SD 1) and minimum object diameter MD7) in mm in combination with sensor type
LL3 Fibre-optic cables
Adapter for WLL12-2 AD-LLBend radius mm
Description
Type
Order no. 5308071 5308072 5308073
Compact sleeve, M4, long scanning range Super compact, sleeve 2.5 mm diameter Super compact, sleeve M3
25 15 10
LL3-DM01 LL3-DT03 LL3-DS06
Long scanning range, M6, coaxial fibre-optic cable 10 m length, M6, coaxial fibre-optic cable
25 25
LL3-DB01 5308074 LL3-DB01-10 5308075
For front lenses, M3 Thin, short sleeve, M4, coaxial fibre-optic cable Highly flexible, M6, long scanning range Highly flexible, small sleeve, M3
15 25 4 4
Highly flexible, 3 mm diameter, thin sleeve
4
LL3-DT01 LL3-DM02 LL3-DR01 LL3-DR02 LL3-DR03
Highly flexible, 1.5 mm diameter, thin sleeve Highly flexible, M4, compact sleeve Supple sleeve, M6, long scanning ranges Supple sleeve, M4 Thin long tip, M3
4 4 25/10 3) 25/10 3) 15
Thin long tip, M3, coaxial fibre-optic cable Diameter 3.0 mm, thin tip, 0.82 mm diameter 90° offset, 5.0 mm diameter 90° offset, small sleeve, 3.0 mm diameter 90° offset, M6 Temperature resistant to 180 °C, M6, long scanning range Temperature resistant to 100 °C, M6 Teflon sheath, resistant to chemicals, 6.0 mm diameter Level switch, clear liquid, 6.0 mm diameter Level switch, cloudy liquid, 6.0 mm diameter 1)
For white scanned object, 90 % remission, minimum object diameter = size of light (aperture LL: approx. 65°) fibre-optic cable not shortened 2) With scanning front lens for LL3, see front lenses for LL3 3) Bend radius of the supple end sleeve 4) Cannot be cut 5) Ambient operating temperature – 40 . . . + 180 °C 6) Ambient operating temperature – 40 . . . + 100 °C 7) Minimum object diameter: scanning range reduction! 8) Cutter FC see page 30
26
SICK
● ● ● 2M2
WLL12-2 Red light
WLL12-2 Infra-red light
SD
SD
MD ● ●
● ●
● 30
MD
● 0.02
12
0.02
●
●
●
5308076 5308077 5308078 5308079 5308080
● ● 2M2
● ●
● ●
LL3-DR044) LL3-DR06 LL3-DB02
5308081 5308082 5308083
2M2
LL3-DM03 LL3-DT02
5308084 5308085
15 4 25 15 25
LL3-DT044) LL3-DR054) LL3-DV01 LL3-DV02 LL3-DV03
5308086 5308087 5308088 5308089 5308090
2M2 2M2
30 25 40 50 50
LL3-DH 015) LL3-DH 026) LL3-DY 01 LL3-DF 01 LL3-DF 02
5308091 5308092 5308093 5308094 5308095
40
● ●
0.02
0.02 ●
●
●
●
● ●
●
●
●
●
●
●
4
● ● ● ●
8
●
0.02
6 4
● ●
0.02 0.02
●
●
● 2M2
● 20
2M2
50
● ● ●
0.03 0.02
15
0.02
● ●
● ●
● ●
●
●
●
●
●
●
● not available
Adaptor for WLL12-2 Type Order no. AD-LL2M2
2015210
LL-l 2.2 mm
23-02-2006
Page 27
LL3 BEFFibre-optic cable Fibre-optic cable Through-beam systems
Features
■ Highly flexible ■ Small bend radii ■ Most fibre-optic cables can be easily cut to length using cutter FC7) (supplied) ■ Operating temperature – 40 … +70 °C, special designs up to 180 °C
Selection table: sensors, fibre-optic cables, scanning ranges Through-beam systems
Scanning range SR 1) and minimum object diameter MD6) in mm in combination with sensor type
LL3 Fibre-optic cables
Adaptor for WLL12-2 AD-LLBend radius mm
Description Standard M4
25
Standard, 3 mm diameter, long range Standard, M4, long range Standard, M4, length 10 m
35 25 25
Highly flexible, M4, long range
4
Highly flexible, M3 Small sleeve, 1.5 mm diameter, highly flexible, length 1 m
4 4
Small sleeve, 1.5 mm diameter, highly flexible, length 2 m 4 Flexible end sleeve, M4 25/103) Compact, M3, end piece 1.0 mm diameter 15
WLL12-2 Red Light
WLL12-2 Infra-red light
SR
MD
SR
MD
Type
Order no.
LL3-TB02 LL3-TS07 LL3-TB01 LL3-TB01-10 LL3-TR01
5308048 5308049 5308050 5308051 5308052
2M2 2M2 2M2
120 180 180
0.2 0.5 0.5
25 45 45
0.2 0.5 0.5
2M2 2M2
70 110
0.5 0.3
25 25
0.5 0.3
LL3-TR02 LL3-TR03 LL3-TR03-2 LL3-TB03 LL3-TT01
5308053 5308054 5308055 5308056 5308057
1M0
25
0.2
4
0.2
● ●
● ●
● ●
● ●
● ●
● ●
● ● ● 2M2 2M2
● ● ●
● ● ●
60 400
0.2 0.5
10
75 70
1.0 0.2
20 15
1.0 0.2
2M2
90° offset, standard, 3 mm diameter 90° offset, compact, 2.5 mm diameter 90° offset, compact, M3 90° offset, standard, 3 mm diameter 90° offset, long range
25 15 15 25 25
LL3-TV01 LL3-TV02 LL3-TV04
5308058 5308059 5308060
LL3-TS08 LL3-TS12
5308061 5308062
Fibre-optic cable cell Temperature-resistant, M4 Temperature-resistant up to 180 °C, M4 Teflon sheath, 6.0 mm diameter, chemically resistant Teflon sheath, 6.0 mm diameter, chemically resistant 90° offset Small end sleeve, M3, long range Small end sleeve M3 Small end sleeve, 1.5 mm diameter
25 25 30 40 40
LL3-TS10 LL3-TH 014) LL3-TH 025) LL3-TY01 LL3-TY02
5308063 5308064 5308065 5308066 5308067
2M2 2M2
160
0.5
30
0.5
2M2 2M2
620 160
0.8 0.5
70 25
0.8 0.5
25 15 15
LL3-TM01 LL3-TM02 LL3-TM03
5308068 5308069 5308070
● 1M0
30
0.2
4
1)
Fibre-optic cable not shortened With scanning front lens for LL3, see front lenses for LL3 3) Bend radius of the supple end sleeve 4) Ambient operating temperature – 40 . . . + 100 °C 5) Ambient operating temperature – 40 . . . + 180 °C 6) Minimum object diameter: scanning range reduction! 7) Cutter FC see page 30
●
0.2 ●
●
●
●
0.2 ●
● not available
2)
23-02-2006
Adaptor for WLL12-2 Type Order no. AD-LL1MO
2015026
LL-l 1.0 mm
AD-LL2M2
2015210
2.2 mm
SICK
27
Page 28
LL3 Plastic fibre-optic cables Befestigungstechnik Flow chart – selection of fibre-optic cables
Fibre-optic cable Proximity System
Coaxial structure for precise switching Fibre-optic cable length 10 m Standard, large scanning range M6
Standard, L = 10 m
Compact head
LL3-DB01
Super-compact head M3
M6
LL3-DB01-10
M4
LL3-DT01
LL3-DM02
Compact end sleeve, excellent scanning ranges Compact head, large scanning range
Super-compact head ø 2,5 ø 2,5
Compact head, M3 M3
M4
LL3-DS06
LL3-DT03
LL3-DM01
Thin end sleeves, long, very thin and flexible end tips: ideal for small, inaccessible objects Standard, flexible end sleeve, large scanning range
Compact head, flexible end sleeve
Compact, thin end tip
ø 0.82 M6
M4
LL3-DB02
LL3-DM03
Compact head, thin end tip
M3
ø 0.82
Super-compact, flexible thin end tip ø 0.82 ø 3
M3
LL3-DT04
LL3-DT02
R4
LL3-DR05
Extremely flexible fibre-optic cable, bend radius R4, for dynamic mechanical systems Flexible, standard, large scanning range
Flexible, compact head
M6
R4
Flexible, small end sleeve
M4
R4
LL3-DR01
M3
R4
LL3-DR06
LL3-DR02
Flexible, extremely short end sleeve
Flexible, extremely short, extremely thin end sleeve
ø3 R4
ø 1.5
LL3-DR03
R4
LL3-DR04
Integrated 90° offset, extremely short installation depths 90° offset
90° offset
M6
90° offset, compact end sleeve ø3 ø 1,5
ø5
LL3-DV03
LL3-DV01
LL3-DV02
Special applications:
Level switches Chemicals High temperature
Resistant up to 100 °C
Resistant up to 180 °C extremely large scanning range
M6
Teflon sheath: resistant to chemicals ø6
Level switch: Clear liquids, resistant to chemicals
Level switch: cloudy liquids, resistant to chemicals
M6
LL3-DH02
LL3-DH01
LL3-DY01
LL3-DF01
LL3-DF02
Accessories: lenses at the front with focused optics Basic fibre-optic cable for scanners with front lenses
LL3-DT01
28
SICK
Small spot, ideal for extremely small parts, high precision
Small spot, ideal for marks, colour recognition, small parts f = 12 mm f = 6 mm
LL3-DA02
LL3-DA01
23-02-2006
Page 29
LL3 BEF Fibre-optic cables Flow chart – selection of fibre-optic cables
Fibre-optic cable Through-beam systems
Standard Fibre-optic cable length 10 m Standard
Standard, long range ø3
M4
LL3-TB02
Standard, long range
LL3-TS07
Standard, L = 10 m M4
M4
LL3-TB01
LL3-TB01-10
Flexible end sleeve, ideal for inaccessible objects M4
LL3-TB03
Thin, short end sleeves Compact end sleeve ø2
Extremely thin, extremely short end sleeve ø 1.5
M3
Compact, long range M3
LL3-TM03
LL3-TM02
Compact head, thin end tip ø3 ø 0.5
LL3-TT01
LL3-TM01
Highly flexible fibre-optic cable, extremely small bend radius R4, for dynamic mechanical systems
Flexible, standard, long range M4
R4
Flexible, extremely small end sleeve M3
Flexible, extremely thin end sleeve ø 1.5
R4
R4
LL3-TR01
LL3-TR02
LL3-TR03 LL3-TR03-2
90°, very small sleeve ø 2.5
ø1
R4
LL3-TV02
Integrated 90°offset, extremely short installation depths 90° offset
90° offset
ø3
90°, very small sleeve ø3
LL3-TS08
R4
LL3-TV01
Special applications:
90°, very small sleeve ø 2.5
ø1
LL3-TV02
90°, long range, easy assembly M3
LL3-TV04
LL3-TS12
Line of fibre-optic cables Chemicals
High temperature Resistant up to 100 °C
M4
Resistant up to 180 °C, large scanning ranges M4
LL3-TH01
Teflon sheath: resistant to ø6 chemicals
LL3-TH02
LL3-TY01
Teflon sheath, 90° offset ø6
LL3-TY02
Line of fibre-optic cables
LL3-TS10
Accessories: front lenses, long ranges (max. 3200 mm), 90° offset
Suitable LL 3 fibre-optic cables LL3-TB02 LL3-TB01 LL3-TB01-10 LL3-TR01 LL3-TH01
23-02-2006
Long ranges
90° offset, extremely short installed depth, long range
LL3-TA01
LL3-TA02
SICK
29
Page 30
Accessories, front lenses Befestigungstechnik Front lenses for through-beam systems
Front lenses for proximity systems
■ Long ranges
■ For detection of very small parts
1 2
Light spot diameter: approx. 170 mm at 1000 mm
■ Focused, very small light spot diameter
Aperture approx. 15° Material: CuZn (nickel-plated)/glass
■ High sensitivity (6 % remission)
3
■ For suppressing interference – causing backgrounds 2
1 2 3
Light spot diameter: approx. 0.25 mm at the focal point = 6 mm Aperture: focus = 6 mm Material: Al (aluminium)/glass M3 Depth 3.4
3
3
4.3
1
ø5
6.8
1
20.4
6 mm 2 Order information Type LL3-TA01
Order information Order no. 5308128
Type LL3-DA01
Order no. 5308127
Front lenses for through-beam systems
Front lenses for proximity systems
■ Compact 90° offset
■ Suitable as a “mark sensor” for colour marks
1 2 3
Light spot diameter: X-axis approx. 110 mm Y-axis: approx. 170 mm, for 200 mm range in each case Aperture, X-axis approx. 30°, Y-axis: approx. 40° Material: CuZn (nickel-plated)/glass
■ Focused, very small light spot diameter ■ High sensitivity (6 % remission) ■ For suppressing interference
– causing backgrounds
3
1 2 3
Light spot diameter approx. 3 mm at the focal point = 12 mm Aperture: focus = 12 mm Material: Al (aluminium)/glass M3 Depth 3.4
3
ø5
1
1
12 mm
4.3
2
5.8 10.9
2 Order information Type LL3-TA02
Order information Order no. 5308129
Type LL3-DA02
Order no. 5308130
Cutter FC *) for fibre-optic cables Type FC
Order no. 5304 141
50
R10
R5
1
2
10
1
37
65
2
Template for bend radius R 10 mm, for sensing tip l 1.5 mm and l 2.5 mm Bend radius R 5 mm
* Supplied with fibre optic cable for cutting it to length 30
SICK
23-02-2006