Spec sheet · Sick
Proximity switch with fibre-optic cables, WLL190T-2
Spec sheet14 pagesPDF 1.8 MB
Data sheet for the SICK WLL190T-2 fibre-optic amplifier: stand-alone, analog output and bus versions, red or green light.
Covers · 1 model
The models it covers
Summary
What is in it
Product data sheets for the SICK WLL190T-2 proximity switch for LL3 fibre-optic cables. Separate sheets cover the stand-alone red light, green light and analog output versions and the bus versions (base and expansion units) with PNP or NPN outputs. Each gives a dimensional drawing, controls and display, connection diagrams for M8 connectors or cable, technical data (scanning range, light source, supply voltage, outputs, response time, enclosure rating, temperatures, weight), sensitivity setting modes and ordering part numbers.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
SICK data sheets dated 2007-04-10 for the WLL190T-2 proximity switch for LL3 fibre-optic cables. They cover stand-alone types in red light, green light and with an analogue output, and bus versions (base and expansion units) in red or green light, PNP or NPN. Each pair of pages gives the dimensional drawing, controls, connection diagrams, technical data and ordering types.
- Device
- Proximity switch for LL3 fibre-optic cables, in stand-alone and bus versions p. 1, 7
- Light source
- LED, red light 650 nm or green light 525 nm, depending on type p. 2, 4
- Red-light ranges
- Red-light stand-alone types: 0 to 480 mm with LL3-DB01; up to 4,000 mm with through-beam LL3-TB01 and tip adapter LL3-TA01 p. 2
- Green-light ranges
- Green-light stand-alone types: 0 to 160 mm with LL3-DM01; up to 4,000 mm with LL3-TB02 and tip adapter LL3-TA01 p. 4
- Supply voltage
- DC 10 ... 24 V (± 10 %); power consumption ≤ 50 mA without load p. 2
- Switching outputs
- NPN or PNP, Q or Q1 and Q2 (Q2 selectable as ext. teach or counter reset); ≤ 100 mA p. 2
- Analogue output
- WLL190T-2N532 and WLL190T-2P532: 4 ... 20 mA p. 6
- Response time
- Selectable 60 µs / 250 µs / 2 ms; switching frequency 8333 Hz / 2000 Hz / 250 Hz p. 2
- Time delay
- Programmable 0 ms to 9000 ms; OFF/TOFF/TON/ONE-SHOT p. 2
- Display and controls
- 2 x 4-digit numeric display, yellow output LED, Teach-in button, two step buttons, Mode/Enter button, SET/RUN selector p. 1
- Teach-in modes
- Normal mode (4 alternatives), Dynamic Teach-in, Zone Teach-in, Glass Teach-in for transparent objects p. 2
- Connection
- Cable PVC 2 m, M8 3-pin or M8 4-pin connector, depending on type p. 2
- Ambient temperature
- Operation -25 °C to +55 °C; storage -40 °C to +70 °C p. 2
- Enclosure
- Stand-alone types IP 66, bus versions IP 54, only with correct LL3 cable adaptation; housing ABS, PC p. 2, 8
What this sheet walks you through
- Fitting the LL3 sender and receiver fibres p. 1
- Using the display, step buttons and Teach-in button p. 1
- Wiring the M8 3-pin and 4-pin connectors p. 1
- Choosing a sensitivity optimization mode p. 2
- Analogue output type p. 5
- Bus versions with base and expansion units p. 7, 8
Good to know
- Ranges are given at 2 ms response time; a shorter response time reduces the range. p. 2
- Cables are not included with delivery; a mounting bracket is included. p. 1
- Bus versions: up to 15 expansion units can be connected, and the operating temperature falls with more units (4 - 8 units: -25 ... +50 °C). p. 8
- The cable must not be bent below 0 °C. p. 2
Questions this sheet answers
What supply voltage does the WLL190T-2 need?
DC 10 to 24 V (± 10 %), with power consumption of 50 mA or less without load. p. 2
Which fibre-optic cables work with the WLL190T-2?
The LL3 series: for red-light types LL3-DB01 (proximity) or LL3-TB01 (through-beam, with tip adapter LL3-TA01); for green-light types LL3-DM01 or LL3-TB02. p. 2, 4
How fast does the WLL190T-2 switch?
Response time is selectable at 60 µs, 250 µs or 2 ms, giving 8333 Hz, 2000 Hz or 250 Hz switching frequency. p. 2
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file