Page 1 of Proximity switch with fibre-optic cables, WLL190T-2

Spec sheet · Sick

Proximity switch with fibre-optic cables, WLL190T-2

Spec sheet14 pagesPDF 1.8 MB

Data sheet for the SICK WLL190T-2 fibre-optic amplifier: stand-alone, analog output and bus versions, red or green light.

Download the PDF1.8 MB

Covers · 1 model

The models it covers

Summary

What is in it

Product data sheets for the SICK WLL190T-2 proximity switch for LL3 fibre-optic cables. Separate sheets cover the stand-alone red light, green light and analog output versions and the bus versions (base and expansion units) with PNP or NPN outputs. Each gives a dimensional drawing, controls and display, connection diagrams for M8 connectors or cable, technical data (scanning range, light source, supply voltage, outputs, response time, enclosure rating, temperatures, weight), sensitivity setting modes and ordering part numbers.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

SICK data sheets dated 2007-04-10 for the WLL190T-2 proximity switch for LL3 fibre-optic cables. They cover stand-alone types in red light, green light and with an analogue output, and bus versions (base and expansion units) in red or green light, PNP or NPN. Each pair of pages gives the dimensional drawing, controls, connection diagrams, technical data and ordering types.

Device
Proximity switch for LL3 fibre-optic cables, in stand-alone and bus versions p. 1, 7
Light source
LED, red light 650 nm or green light 525 nm, depending on type p. 2, 4
Red-light ranges
Red-light stand-alone types: 0 to 480 mm with LL3-DB01; up to 4,000 mm with through-beam LL3-TB01 and tip adapter LL3-TA01 p. 2
Green-light ranges
Green-light stand-alone types: 0 to 160 mm with LL3-DM01; up to 4,000 mm with LL3-TB02 and tip adapter LL3-TA01 p. 4
Supply voltage
DC 10 ... 24 V (± 10 %); power consumption ≤ 50 mA without load p. 2
Switching outputs
NPN or PNP, Q or Q1 and Q2 (Q2 selectable as ext. teach or counter reset); ≤ 100 mA p. 2
Analogue output
WLL190T-2N532 and WLL190T-2P532: 4 ... 20 mA p. 6
Response time
Selectable 60 µs / 250 µs / 2 ms; switching frequency 8333 Hz / 2000 Hz / 250 Hz p. 2
Time delay
Programmable 0 ms to 9000 ms; OFF/TOFF/TON/ONE-SHOT p. 2
Display and controls
2 x 4-digit numeric display, yellow output LED, Teach-in button, two step buttons, Mode/Enter button, SET/RUN selector p. 1
Teach-in modes
Normal mode (4 alternatives), Dynamic Teach-in, Zone Teach-in, Glass Teach-in for transparent objects p. 2
Connection
Cable PVC 2 m, M8 3-pin or M8 4-pin connector, depending on type p. 2
Ambient temperature
Operation -25 °C to +55 °C; storage -40 °C to +70 °C p. 2
Enclosure
Stand-alone types IP 66, bus versions IP 54, only with correct LL3 cable adaptation; housing ABS, PC p. 2, 8

What this sheet walks you through

  • Fitting the LL3 sender and receiver fibres p. 1
  • Using the display, step buttons and Teach-in button p. 1
  • Wiring the M8 3-pin and 4-pin connectors p. 1
  • Choosing a sensitivity optimization mode p. 2
  • Analogue output type p. 5
  • Bus versions with base and expansion units p. 7, 8

Good to know

  • Ranges are given at 2 ms response time; a shorter response time reduces the range. p. 2
  • Cables are not included with delivery; a mounting bracket is included. p. 1
  • Bus versions: up to 15 expansion units can be connected, and the operating temperature falls with more units (4 - 8 units: -25 ... +50 °C). p. 8
  • The cable must not be bent below 0 °C. p. 2

Questions this sheet answers

What supply voltage does the WLL190T-2 need?

DC 10 to 24 V (± 10 %), with power consumption of 50 mA or less without load. p. 2

Which fibre-optic cables work with the WLL190T-2?

The LL3 series: for red-light types LL3-DB01 (proximity) or LL3-TB01 (through-beam, with tip adapter LL3-TA01); for green-light types LL3-DM01 or LL3-TB02. p. 2, 4

How fast does the WLL190T-2 switch?

Response time is selectable at 60 µs, 250 µs or 2 ms, giving 8333 Hz, 2000 Hz or 250 Hz switching frequency. p. 2

Is there a WLL190T-2 with an analogue output?

Yes, the WLL190T-2N532 and WLL190T-2P532 have a 4 to 20 mA analogue output. p. 5, 6

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7
  2. Pages 8 to 148-14

The file

Revision and size

Revision2007-04-10
PublisherSICK
Pages14
PDF1.8 MB
TextText from the PDF itself.

The first pages · 4 of 14

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 14
Page 2
Page 2of 14
Page 3
Page 3of 14
Page 4
Page 4of 14