Two SICK catalog pages on the WL 2000 red-light reflex (retro-reflective) sensors for DC, types WL 2000-B1302 to WL 2000-B4300. They give highlights, the dimensional drawing, adjustments, technical data and M12 connection diagrams. The pages name only the WL 2000 types.
- Device
- Reflex (retro-reflective) photoelectric sensor, red light, DC, rugged plastic housing p. 1
- Sensing range
- 0 to 59 ft (0 to 18 m) p. 1, 2
- Types
- WL 2000-B1302, B1312, B1322, B5300, B5310, B5320, B4300 p. 1
- Outputs
- PNP output QP and NPN output QN, plus an alarm output p. 1, 2
- Connection
- Cable 2 m PVC, M12 5-pin plug, or M12 4-pin plug p. 2
- Indicators
- Power LED (green), signal strength LED (red), output LED (yellow) p. 1
- Adjustments
- ON delay selector, OFF delay selector, light/dark switching selector, sensitivity p. 1
- Time delays
- 0, 5, 10, 20 or 50 ms p. 1
- Ambient temperature
- Operation -13 to 104 °F (-25 to 40 °C); storage -40 to 158 °F (-40 to 70 °C) p. 2
- Mounting thread
- Internal 1/2 - 14NPSM; external M30 x 1.5 p. 1
- Features
- Polarizing filters against false readings on shiny surfaces; crosstalk immunity; red light for alignment p. 1
What this sheet walks you through
- Mounting dimensions in inches and millimeters p. 1
- Setting the ON and OFF time delays p. 1
- Choosing a reflector by sensing range p. 1
- Wiring the 5-pin and 4-pin M12 connectors p. 2
Good to know
- The cable must not be bent below 0°C. p. 2
- Wire colors in the diagrams refer to the standard cable, which is not included with quick disconnect models. p. 2
Questions this sheet answers
What is the sensing range of the SICK WL 2000?
0 to 59 ft (0 to 18 m). p. 2
What do the LEDs on the WL 2000 mean?
Green is power, red is signal strength, and yellow is the output. p. 1
What connection options does the WL 2000 have?
A 2 m PVC cable, or an M12 quick disconnect plug in 5-pin or 4-pin form. p. 1, 2
What is the operating temperature of the WL 2000?
-13 to 104 °F (-25 to 40 °C); storage is -40 to 158 °F (-40 to 70 °C). p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
WL 2000 Highlights
Reflex/Retro-Reflective Sensors
- Rugged plastic housing RED
DC
- Standard mounting for your existing applications
- Polarizing filters prevent false readings on shiny surfaces
- Red light for easy alignment
- Alarm output
- Selectable time delays
sensing range
- Crosstalk immunity
- Cable or M12 quick disconnect versions
WL 2000Dimensional Drawing0...59 ft (0...18 m)1 1.8 2 (45)1.9 (48.6)340.7 (16.9)2.9 (73.7)0.9 (22.2)2.1 (52.3)5 6
6 0.2 x 0.8 (5.7 x 7.8) slots Internal thread (1/2 - 14NPSM) External thead (M30 x 1.5)
1.0 (25)
0.4(9.8)
1.3 (32.1) dimensions in inches (mm) Excess Gain 0
2
4
1 LED power indicator (green) 2 LED signal strength indicator (red) 3 LED output indicator (yellow) 4 Center of optical axis, sender 5 Center of optical axis, receiver 6 Mounting through-hole Ø 0.2 x 0.8 mm, 7 ON delay selector 8 OFF delay selector 9 Light/dark switching selector
Adjustments 681012141618 (m)All typesexcess gain4 3 2 11 06.613.119.726.332.839.445.952.5Sensitivity +Light Dark 0¤ 159.1 (ft)7msSignalOutputPL80A 10
Time Delay 4321 0¤0001¤ 5¤0010¤ 10¤0100¤ 20¤1000¤ 50 0000
Power100OperateOn Delay4 3 2 1 0¤ 1 Off Delay89
Reflector Type 1 2 3 4 5 6
Sensing RangeOrder InformationPL 80 A PL 50 A1. . .15 m 0 . . .11 m
PL 40 A PL 30 A PL 20 A Reflective tape diamond grade
0 . . .11 m 0. . . 8 m 0...8 m 0. . . 8 m
Type WL 2000-B1302 WL 2000-B1312 WL 2000-B1322 WL 2000-B5300 WL 2000-B5310 WL 2000-B5320 WL 2000-B4300
Cables and connectors Reflectors
page 909 936Mounting brackets927
Accessories Part no. 7 023 044 7 023 045 7 023 046 7 023 047 7 023 048 7 023 049 7 024 002
328
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
B1302 B1312 B1322 B5300 B5310 B5320 B4300
WL 2000-
Technical Data Sensing range
0...59 ft (0...18 m)
Light source 1), light type Light spot diameter Angle of divergence
LED, red light, 660 nm, polarized Approx. 12.5 in at 45.9 ft (320 mm at 14 m) Approx. 1.3°
Supply voltage VS Ripple 3) Current consumption 4)
10...30 V DC ≤5V ≤ 80 mA – PNP or NPN, Q and Q 2V Light/dark switching via switch 80 mA ≤ 1 ms 500 Hz PNP 0, 5, 10, 20 or 50 ms
Switching outputs Voltage drop (Max.) Operation mode Output current lA max. Response time 5) Max. switching frequency 6) Alarm output Time delay settings OFF delay ON/OFF delay Connection types
Cable, 2 m, PVC Plug, M12 5-pin Plug, M12 4-pin
VDE protection class 8) Circuit protection 9) Enclosure rating
A, B, C IP 67/NEMA 6
Approximate weight Housing material
Operation -13...104°F (-25...40°C) Storage -40...158°F (-40...70°C) 5.3 oz (150 g) Glass fiber reinforced plastic
1) Average service life 100,000 h at TA = 25°C 2) Limit values 3) May not exceed or fall short of VS tolerances
4) Without load 5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0°C 8) Reference voltage 50 V DC
Ambient temperature TA
9) A = VS connections reverse-polarity protected – B = Output Q and Q short-circuit protected C = Interference pulse suppression
Connection Diagram M12 Connector 1 2 5 4 3
brown white gray black blue
DC 10...30 V QN - NPN output alarm output QP - PNP output
21load load5 0V34
wire colors refer to standard cable, not included with quick disconnect models
M12 Connector 1 2 4 3
brown white black blue
DC 12...30V QN - NPN output QP - PNP output
load load21340V329