Page 17
Product description
Operating Instructions
Chapter 3
NAV200
3
Product description 3.1
Design of the system
3.1.1
Scope of delivery (without data cable)
Additionally required:
NAV200
8-pin cable socket
RS 232 data cable Must be ordered separately due to different lenghts! See Table 10-3, Page 80.
Fig. 3-1:
NAV200 laser positioning system with cable socket
The delivery package of a NAV200 comprises: •
NAV200 with rotating scanner head
•
8-pin cable socket for power supply (No. 6024722)
•
Information sheet (device information)
•
CD-ROM (No. 2040168) with – NAV200 Setup configuration software for WindowsTM – NAV200 operating instructions in German and English (PDF) – NAV200 telegram listing in German and English (PDF) – The freely-available "Acrobat Reader" PC software for reading PDF files
•
Screw kit (No. 2026277) for fixing the NAV200, consisting of – 4 x hexagon socket (Allen) screws M4 x 10 mm (0.39 in) - A2 – 4 x washers 4.3 - A2 – 4 x spring lock washers B4
The required RS 232 data cable must be ordered separately. Note
The latest versions of all the current publications/documentation included in the scope of delivery are available for download at www.sick.com. Section 10.2 Available accessories, Page 80 also gives an overview of the accessories available, e.g. the required RS 232 data cable.
8011502/R197/2007-02-12
© SICK AG · Division Auto Ident · Germany · All rights reserved
17
Page 18
Chapter 3
Product description
Operating Instructions NAV200 Laser Positioning System
3.1.2
System requirements
As part of a navigation system, the NAV200 is controlled by a supervisory unit - the vehicle computer. Application-specific software that enables communication between vehicle computer and NAV200 is required for this task. The user can write suitable software for his application on the basis of the software telegrams described in the NAV200 telegram listing (No. 8009595). Other requirements are: –
Sub-division of the area to be travelled into separate layers
–
Mounting of fixed reflectors in these layers
–
Accurate measurement of the reflector positions (co-ordinates) from a common origin (zero point) of the area
–
Transfer of this layer-related reflector data to the NAV200
SICK offers "Diamond Grade" reflective film as an accessory for constructing suitable reflectors, see Section 10.2 Available accessories, Page 80. The sub-division and equipping of layers with reflectors is described in Section 3.3 Operating conditions, Page 22. Other requirements for commissioning and operating a NAV200 are: Mounting: •
Flat mounting surface (support, not included in the scope of delivery) for mounting the NAV200 on an automated guided vehicle (AGV). The NAV200 is mounted parallel to the area travelled.
Electrical connection •
Bringing the power supply (24 V DC ± 25 %) into the 8-pin cable socket (included in the scope of delivery).
•
A supervisory vehicle computer (host) with an RS 232 data interface for processing the measurement data.
Commissioning/Configuration •
PC with RS 232 serial data interface, CD disk drive, mouse and Windows 98TM, Windows METM, Windows 2000TM or Windows XPTM operating system.
•
RS 232 data cable No. 6024723 (5 m (16.4 ft))/No. 2030334 (6.5 m (21.3 ft))
3.1.3
Product features and functions (overview)
Powerful NAV200:
18
•
Use on courses with a maximum of 40 layers and a maximum of 32 reflectors per layer
•
Detection of reflector marks in a 360° scanning angle
•
Range 1.2 m to 28.5 m (3.94 ft to 93.5 ft)
•
Position measurement accuracy ±4 mm to ±25 mm (±0.16 in to ±0.97 in) (depending on mean distance to reflector)
•
Angular accuracy ±0.1°
•
Mounting position with optical axis parallel to the area travelled, overhead mounting also possible
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011502/R197/2007-02-12
Page 19
Operating Instructions
Product description
Chapter 3
NAV200
Safety and convenience for the user: •
Robust, compact metal housing (max. IP 65), CE mark
•
Laser Class 1
•
Future-proof through firmware update via serial data interface (Flash PROM)
•
Future-proof NAV200 Setup configuration software
•
Maintenance-free
Convenient configuration/operation: •
Convenient NAV200 Setup configuration software
•
Command interface with software telegrams for measurement, modification and storage of reflector co-ordinates
•
Four status-display LEDs
Modes: •
Standby (manual entry of the reflector positions in the NAV200)
•
Mapping (automatic measurement of the reflector positions by the NAV200)
•
Positioning operation (continuous position measurement by the NAV200)
•
Upload (reading the reflector positions stored in the NAV200)
•
Download (transferring new reflector positions to the NAV200)
•
Reflector co-ordinates (reflector measurement) in the local co-ordinate system of the NAV200)
External data communication: •
RS 232 serial data interface to the vehicle computer (host) and to the PC for configuring the NAV200
Electrical interfaces •
Power supply (24 V DC ± 25 %)
•
RS 232 data interface
Type of connection: •
RS 232 data interface, 14-pin chassis-mount plug on device
•
Power supply ("Power Supply 24 V DC" connection): 8-pin chassis-mount plug on device
3.1.4
Applications
Typical applications for the NAV200 are:
8011502/R197/2007-02-12
•
Shuttle systems
•
Self-propelled stackers
•
Automated guided transport systems generally
© SICK AG · Division Auto Ident · Germany · All rights reserved
19
Page 20
Product description
Chapter 3
Operating Instructions NAV200 Laser Positioning System
3.1.5
View of the device
1
4 5 2 6
3 bm 3 green red yellow yellow
7
8
9 bl
Legend:
1 Scanner head, rotating 2 Light outlet/inlet aperture 3 Status indicator (LEDs 4 x) 4 RS 232 data cable (see Table 10-3, Page 80)
5 9-pin D-Sub socket for Host/PC connection
20
(14-pin chassis-mount plug)
8 "Power Supply 24 V DC" connection (8-pin chassis-mount plug)
9 Fuse (3.15 A slow-blow) bl Functional earth terminal bm Tapped holes in baseplate (4 x) (not visible here)
6 14-pin cable socket for
Fig. 3-2:
7 “RS 232 data interface” connection bn Laser warning label bo 8-pin cable socket
Arrangement of the NAV200
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011502/R197/2007-02-12
Page 21
Operating Instructions
Product description
Chapter 3
NAV200
3.2
How the NAV200 works
When mounted on an automated guided vehicle (AGV), the NAV200 continuously measures its own current position as the AGV moves on the route. When requested, it transfers the positional data to the vehicle computer of the AGV. The vehicle computer steers the AGV along the programmed and hence preset route and, using the NAV200, corrects any course deviations that occur. On each request, the vehicle computer informs the NAV200 of the current speed of the AGV on the course. The NAV200 calculates its own position and orientation on the basis of fixed reflectors positioned in the environment, whose co-ordinates it detects, two-dimensionally, in a 360° scanning angle using a laser beam invisible to the human eye (Fig. 3-3). One revolution of the scanner head here is equivalent to a scan and each revolution generates one reading per detected reflector. The co-ordinates of the reflectors used are stored in the nonvolatile reflector memory of the NAV200 as a reference datum. With a change to "Mapping" or "Positioning operation” (position measurement) modes, the NAV200 loads the reflector data from its reflector memory into the internal working memory. Reflector data stored in the NAV200 is assigned in groups to so-called layers. Each layer represents a permanently defined area in the overall course that the AGV travels over. By changing over to the associated layer, the NAV200 always only uses the reflectors that belong to the area it is currently travelling in with the comparison measurement for the detection. The changeover is made by the vehicle computer, dependent on the vehicle location. Three detected reflectors in a layer are sufficient for position measurement. For position measurement, the NAV200 measures the distances to and angles of the reflectors and works out its own position from this data.
Reflektor Reflector NAV200 AGV FTF
Fig. 3-3:
8011502/R197/2007-02-12
Position measurement of the NAV200 by detection of reflector arrangements
© SICK AG · Division Auto Ident · Germany · All rights reserved
21
Page 22
Product description
Chapter 3
Operating Instructions NAV200 Laser Positioning System
3.3
Operating conditions
3.3.1
Installation requirements
The mounting position of the NAV200 should be chosen such that the scanning plane formed by the rotating optical axis runs parallel to the area travelled. The scanner head can be positioned above or below (overhead mounting) the scanner housing here. A clear view over the entire 360° scanning width must be ensured from the mounting position of the NAV200. With overhead mounting, the mounting bracket should be selected so that the restriction of vision occurs in or against the direction of travel. This will ensure an adequate view of the reflectors along the route. The reference point (co-ordinates origin) on the NAV200 lies on the central axis of the scanner head. In an ideal case, the central axis of the scanner head would lie in the navigational point of the vehicle. If the mounting position of the NAV200 in the longitudinal axis of the vehicle is offset either in front of or behind the turning point, this deviation must be taken account of mathematically in the programming of the vehicle computer. Note
With the normal installation (scanner head at the top), the scanner head rotates clockwise when viewed from above. With overhead mounting, on the other hand, the rotation is counter-clockwise. This must be taken into account and adapted if necessary for the display of the measurement results in the NAV200 Setup configuration software (see also Fig. 6-7, Page 57). The functional earth of the NAV200 must be electrically connected to the chassis of the AGV as part of the electrical installation, see Section 5.2.3 Screening concept, Page 41. 3.3.2
Designing reflector arrangements
Reflector arrangements should be designed so that the NAV200 has a clear view of at least 3 reflectors from any position. A clear view of 4 to 5 reflectors is recommended to also ensure reliable positioning when several AGVs are operating. As equal a number of reflectors as possible should be fitted on both sides of the route here. An asymmetrical arrangement of the reflectors is required for an unambiguous assignment of the reflector position measurements to the reflector arrangement of the layer, see Section 3.3.5 Reflector arrangements within a layer, Page 27. At positions where high positioning accuracy is required, like docking stations or curved areas, for example, the NAV200 requires 4 or more reflectors within a distance of the restricted radius of action to be defined here. In addition, the angular difference between 2 reflectors measured by the NAV200 must not be more than 120°. At positions where the NAV200 is brought on to the route, at least 4 to 6 reflectors must fall within the range of the NAV200. In addition, the angular difference between 2 reflectors measured by the NAV200 must not be more than 120°. With flat reflectors, the detection angle of the reflector must be considered, see Section 3.3.3 Reflectors, Page 22. 3.3.3
Reflectors
The NAV200 assigns the readings acquired from its environment to the stored reflector positions. To do this, it must distinguish between the reflectors and other reflective objects. For this, the NAV200 checks the readings against characteristic values that are stored in its memory. These characteristic values apply for Diamond Grade 3000X reflective film (No. 5304334), available as an accessory at SICK AG. Note
22
Other brands of reflective film may not be correctly detected by the NAV200.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8011502/R197/2007-02-12
Page 23
Product description
Operating Instructions
Chapter 3
NAV200
Styles The reflector marks can be in the form of reflector strips (reflector bars) or cylindrical reflectors. Reflector strips have a limited detection angle and are especially suitable for wide-area applications. Cylindrical reflectors can be detected from any angle and are especially suitable for use in narrow aisles. Note
Only one type of reflector must be used within a layer. Reflector height The overall height and vertical position of the reflectors should be selected so that the measurement beam hits the reflectors, even with uneven floors. The maximum range of the system is 28.5 m (93.5 ft). The minimum height of the reflectors can be derived from this, depending on the nature of the floor and the resulting measuring distance. The measurement beam of the NAV200 diverges by 16 mm (0.63 in) per metre of measuring distance. Appropriate consideration must be given to possible tilting of the AGV due to uneven floors. Common reflector overall heights are between 500 mm (19.7 in) and 750 mm (29.6 in). Reflector width and reflector diameter The minimum width of flat reflectors is 100 mm (3.88 in). The width of flat reflectors can vary within a layer, provided that the minimum width is maintained. There is no restriction on the vertical width of the reflector. The minimum diameter of cylindrical reflectors depends on the measuring distance. For distances up to 15 m (49.2 ft), the minimum diameter is 80 mm (3.11 in). For distances above 15 m (49.2 ft) the minimum diameter is 100 mm (3.88 in). The diameter of cylindrical reflectors must be constant within a layer. Detection angle with flat reflectors In order to detect a reflector, the measurement beam emitted by the scanner head of the NAV200 must be reflected back to the scanner head. When the measurement beam hits the reflector at right angles (detection angle = 0°), a flat reflector acts like a mirror. But the special Diamond Grade 3000X reflective film also reflects the measurement beam back to the scanner head when it hits the film at different detection angles. The detection angle is not dependent on the measuring distance. Fig. 3-4 shows the detection angle of flat reflectors with optimal alignment of the reflective film to the measurement beam, see also the following section "Alignment of the reflective film“:
(98.42 ft) (65.62 ft) Fig. 3-4:
8011502/R197/2007-02-12
(32.81 ft)
(32.81 ft) (65.62 ft) (98.42 ft)
Detection angle with 100 mm (3.88 in) wide reflector strips made of Diamond Grade 3000X reflective film (0° = vertical striking of the measurement beam)
© SICK AG · Division Auto Ident · Germany · All rights reserved
23
Page 24
Chapter 3
Product description
Operating Instructions NAV200 Laser Positioning System
Alignment of the reflective film The reflective properties of Diamond Grade 3000X reflective film depend on the alignment. The alignment varies with the date of manufacture of the reflective film. In earlier versions of the film, the structure of the microreflectors can be seen by the naked eye. With the new film, the structure is so fine that the human eye is no longer capable of resolving it. The detection angle given in Fig. 3-4, Page 23 can only be achieved with the following alignments: •
Vertical alignment of the honeycomb separator strips with reference to the scanning plane (production date of the reflective film before July 2002). Vertical honeycomb
Fig. 3-5:
•
Alignment of Diamond Grade 3000X reflective film, production date before July 2002
Horizontal alignment of the honeycomb separator strips with reference to the scanning plane (production date of the reflective film after July 2002). Horizontal honeycomb
Fig. 3-6:
Alignment of Diamond Grade 3000X reflective film, production date after July 2002 (version currently supplied)
Reference points of the reflectors In order to determine the co-ordinates of a reflector unambiguously with the NAV200, the reflector area must be reduced to a reference point.
24
•
With reflector strips, the reference point is located at the point of intersection of the vertical centre line with the scanning plane; this is normally halfway up the reflector.
•
With cylindrical reflectors, the reference point is located at the point of intersection of the vertical central axis of the cylinder with the scanning plane; this is normally halfway up the reflector.
© SICK AG · Division Auto Ident · Germany · All rights reserved