Page 73

Maintenance

Operating Instructions

Chapter 7

NAV200

7

Maintenance 7.1

Maintenance during operation

To maintain optimum measuring performance, the front pane in the scanner head of the NAV200 must be kept clean. We recommend that the scanner head is checked for dirt on a regular basis (e.g. weekly), particularly in a harsh operating environment (dust, abrasives, humidity); more frequent checks may be appropriate, depending on the environment. No regular maintenance is required to ensure that the Class 1 laser classification is maintained. Note

Do not open the housing of the NAV200. Opening the device will invalidate the manufacturer's warranty. 7.1.1

Cleaning the front pane of the NAV200

Laser radiation! The NAV200 uses a Class 1 laser. The entire window area is used as the laser outlet aperture. The invisible infra-red radiation emitted is safe to eyes. Caution, use for other than the intended purpose can lead to exposure to dangerous radiation. ¾

Do not open the housing (opening does not stop the laser switching on)

¾

Use for other than the intended purpose can lead to the laser class being exceeded.

¾

Observe the latest version of the laser protection regulations.

Damage to the NAV200! The NAV200 provides IP 65 protection and is only protected against the ingress of liquids in that respect. ¾

Do not immerse the device in liquids.

¾

If necessary, clean the housing with a moist, soft cloth (lint-free)

¾

Do not use aggressive chemicals!

Damage to the front pane! The front pane is made of glass. Scratches and smears on the front pane can adversely affect the measuring performance.

8011502/R197/2007-02-12

¾

Always moisten the front pane when cleaning it.

¾

Use a mild cleaner that does not contain abrasive powder. Never use strong cleaners or solvents such as acetone etc.

¾

Avoid scratching and scouring movements on the front pane.

© SICK AG · Division Auto Ident · Germany · All rights reserved

73

Page 74

Maintenance

Chapter 7

Operating Instructions NAV200 Laser Positioning System

1.

Switch the NAV200 off for cleaning, as otherwise the scanner head rotates.

2.

Clean the front pane at regular intervals using a a damp cloth (lint-free) and a proprietary window cleaner, or with a special soft brush for lenses (camera/optical accessory).

3.

Also clean the LED cover if necessary.

clean here clean here

Fig. 7-1:

Note

Cleaning the front pane on the NAV200

If the front pane is scratched or damaged (crack, break) the glass must be replaced. Contact Sick Service for this.

7.2

Maintenance

Apart from the routine cleaning described above, the NAV200 is maintenance free. The NAV200 outputs device and functional errors as they occur in the form of a special error telegram, in the reply to any vehicle computer software telegram, see Section 8 Troubleshooting, Page 75.

7.3

Disposal

Dispose of any unusable/irreparable NAV200 devices that are taken out of service in an environmentally-responsible manner: 1.

Observe the applicable country-specific waste disposal regulations.

2.

Disassemble the housing of the NAV200.

3.

Disassemble the electronics modules of the NAV200.

4.

Remove the front pane of the NAV200 and send it for glass recycling.

5.

Send the die-cast aluminium frame and cover of the NAV200 for non-ferrous metals recycling.

6.

Dispose of the electronics modules as special waste.

7.

Send the cables for metal recycling

SICK AG does not currently take back devices that have become unusable or irreparable.

74

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011502/R197/2007-02-12

Page 75

Operating Instructions

Troubleshooting

Chapter 8

NAV200

8

Troubleshooting The NAV200 reports all error conditions to the AGV vehicle computer in the form of error messages via the RS 232 data interface. They can be interpreted by the supervisory control software there. The structure of the error telegrams and the possible types of error are described in the “NAV200 Telegram Listing” (No. 8009595).

8.1

Overview of possible errors and malfunctions

8.1.1

Mounting errors

•

Rotating optical axis of the NAV200 is not aligned parallel with the travelled plane.

8.1.2

Electrical installation errors

•

Faulty link between PC and NAV200

•

Faulty link between vehicle computer and NAV200

•

Wrong conductor cross-section selected for the supply

8.1.3

Parameter setting error

•

Parameter values not adjusted to local conditions

•

Device-related limits (range) not taken into account

8.1.4 •

8.2

Operational malfunctions

Device errors (hardware/software)

Monitoring errors and fault signs

The NAV200 signals device errors and functional errors on the basis of software telegrams that it sends to the vehicle computer via the serial data line. In addition, the NAV200 switches off all four LEDs in an error state.

8.3

SICK support

If a fault cannot be cleared with the measures described earlier, the NAV200 itself may be faulty. The system has no components that the user can repair himself to restore their functionality after a failure. Please contact your local Sick office or subsidiary:

8011502/R197/2007-02-12

•

The telephone numbers and email addresses are listed on the back page of these operating instructions. For postal addresses see also www.sick.com.

¾

Please consult SICK Service before returning the device.

© SICK AG · Division Auto Ident · Germany · All rights reserved

75

Page 76

Troubleshooting

Chapter 8

Operating Instructions NAV200 Laser Positioning System

Notes:

76

© SICK AG · Division Auto Ident · Germany · All rights reserved

8011502/R197/2007-02-12