Page 1 of SICK LUT 1-4 Luminescence Scanners Technical Data

Spec sheet · Sick

SICK LUT 1-4 Luminescence Scanners Technical Data

Spec sheet2 pagesPDF 238 KB

Both pages are below, each with its text.

Download the PDF238 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Two SICK catalog pages on the LUT 1-4 luminescence scanners, variants LUT 1-400 through LUT 1-450. They give the dimensional drawing, connection pins, an output truth table, technical data and order numbers. A reader can identify a variant by its part number and find its colour filters and spare lamp.

Device
Luminescence scanner with a UV light source using a high-pressure mercury vapour lamp p. 1
Part numbers
LUT 1-400: 1 007 626; LUT 1-410: 1 005 935; LUT 1-420: 1 005 936; LUT 1-430: 1 005 937; LUT 1-440: 1 005 938; LUT 1-450: 1 005 939 p. 2
Switching outputs
QL (signal output) and QB (operational readiness), PNP, light- or dark-switching selectable p. 2
Connection pins
7-pin + PE: L+, M, QL, QB, QA, NC, NC, PE p. 1
Indicators
Readiness indicator (red) and status indicator (green) p. 1
Optics
Scanning distance set by interchangeable lenses; fibre-optic connection; additional optical filter p. 1
Ambient temperature
Operation -10 °C to +45 °C; storage -25 °C to +75 °C p. 2
Colour filters
OBF-OG 570-4, OBF-RG 610-4, OBF-RG 630-4, OBF-RG 665-4 p. 2
Spare lamp
SLA-LUT 1-4 p. 2

What this sheet walks you through

  • Choosing a LUT 1-4 variant by its part number p. 2
  • Reading the output and indicator states for light- and dark-switching p. 1
  • Mounting dimensions of the housing p. 1

Good to know

  • A flashing state in the truth table means the lamp power is still sufficient for operation. p. 1
  • Scanning distances are measured from the front edge of the lens. p. 2

Questions this sheet answers

What is the part number of the LUT 1-410?

The order table lists the LUT 1-410 as part number 1 005 935. p. 2

What is the operating temperature of the LUT 1-4 scanner?

-10 °C to +45 °C in operation; storage is -25 °C to +75 °C. p. 2

Which spare lamp fits the LUT 1-4?

The accessory list names the spare lamp SLA-LUT 1-4. p. 2

What outputs does the LUT 1-4 have?

PNP switching outputs QL (signal) and QB (operational readiness), light- or dark-switching selectable, plus an analogue output QA. p. 2

The file

Size and text

Pages2
PDF238 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of SICK LUT 1-4 Luminescence Scanners Technical Data

The text of page 1, from the PDF itself

LUT 1-4 Luminescence scanners Dimensional drawing

253138460.550"X"A"X"12 0°A-B3030°R 3.360° 12930M5Bø48,5 ø621012535371

  • UV semi-conductor light source

with high-pressure mercury vapour lamp

  • Scanning distance selectable by using interchangeable lenses
  • Fibre-optic connection
  • Additional optical filter

6425LUT 1-410 LUT 1-420LUT 1-430 LUT 1-440LUT 1-450131012Adjustments possible5050All types50200Luminescence scannersø50 88

Scanning distance 10 . . . 90 mm

OUTPUT NOT READY /ALARM

1 2 3t on/off [ms]2.54 50.1E max6SENSITIVITY[E]

Connection type Bridge LUT 1 - 4

C V

Accessories Cable receptacles Fibre-optic cable

page 496 5527-pin + PE red1Lenses556blu2grn3brn4wht5blk6 7yel422SENSICK CATALOGUE

Lens, see dimensional drawing Readiness indicator Status indicator Sensitivity adjustment Digital intensity signal Threaded mounting hole, 12 mm deep

Truth table LUT 1 - 4 Internal jumper

oaobo

oaobo

Switching type Sender lamp

Delivered state Light-switching started off

Dark-switching started off

Luminescence Output QB (PNP) Readiness indicator (red) Output QL (PNP) Status indicator (green)

– LOW on LOW off

yes no HIGH off/flashing*) HIGH on

LOW off

– LOW an LOW off

yes no HIGH off/flashing*) LOW on

  • Flashing: lamp power still sufficient for operation

L+ M QL QB QA NC NC PEa bHIGH off

Page 2 of SICK LUT 1-4 Luminescence Scanners Technical Data

The text of page 2, from the PDF itself

LUT 1-4 Technical Data

LUT 1-

Scanning distance1)/ light spot diameter

With fibre-optic cable, no lens With fibre-optic cable, with 144 lens With fibre-optic cable, with 144 lens and diaphragm

410420430440

High-pressure mercury vapour lamp UV, 365 nm 4000 h 18 . . . 30 V DC 2) 2V 700 mA

Switching outputs QL5) and QB6)

Light-/dark-switching, selectable PNP: HIGH = VS – < 2 V/LOW = 0 V 200 mA 5 kHz 200 Hz 0.1 ms 2.5 ms 0 . . .1.5 V Plug

VDE protection class 8) Circuit protection 9) Enclosure rating

V

Ambient temperature

Operation – 10 °C . . . + 45 °C Storage – 25 °C . . . + 75 °C 2.5 kg Die-cast metal

A, B, C IP 63

Weight Housing material/surface 1) From front edge of lens 2) Limit values 3) May not exceed or fall short of VS 4) Without load

5) QL = signal output 6) QB = operational readiness

7) With light/dark ratio 1:1 8) Reference voltage DC 50 V

9) A = VS connections reverse-polarity protected B = Outputs QL, QB and QLU short-circuit protected C = Interference pulse suppression

Scanning distance 1 2 3 4 5

200 1 100 502Rel. sensitivity in %

10 mm 20 mm 50 mm 125 mm 300 mm

5 5

20

Order information Type Part no. LUT 1-400 1 007 626 LUT 1-410 1 005 935 LUT 1-420

1 005 936LUT 1-4301 005 937LUT 1-4401 005 938LUT 1-4501 005 939

Special accessories Colour filter

4105 10

Scanning distance Scanning distance Scanning distance Scanning distance Scanning distance

320(mm) 2450

10 mm/l 3 mm 20 mm/l 4 mm 50 mm/l 8 mm 125 mm/l 15 mm 300 mm/l 40 mm 8 mm/l 10 mm 15 mm/l 6 mm 15 mm/l 3 x 6 mm

Light source Light type, wavelength Average service life Supply voltage VS Ripple 3) Current consumption 4)

Output current lA max. Max. switching frequency 7) At max. sensitivity Response time At max. sensitivity Analogue output QA Connection type

40050 100 200 500 1000TypeWavelengthPart no.

OBF-OG 570-4 OBF-RG 610-4

570 . . . 750 nm 610 . . . 750 nm

4 005 810

OBF-RG 630-4 OBF-RG 665-4 Spare lamp

630 . . . 750 nm 665 . . . 750 nm

SLA-LUT 1-4

4 012 735 4 014 153 4 014 154 1 002 262

SENSICK CATALOGUE

423