Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a spec sheet · part 3 of 4

Product Information: CLV620, CLV630, CLV640: Intelligence for logistics and automation, pages 21 to 30

Pages 21 to 30 of 40

The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV640

Page 21

Order information, CLV62x variants.

Ty p e

CLV620

CLV621

CLV622

2008-04

Read range

Mid-range

Long-range

Short-range

Scanning process

Read window

Standard version with 15-pin D-sub HD plug

Ethernet version with 2 x M12 plug connectors

Type

Part number

Type

Part number

Line

Front

CLV620-0000

1040288

CLV620-0120

1041547

Raster

Front

CLV620-1000

1041548

CLV620-1120

1041549

Line

Side

CLV620-2000

1041550

CLV620-2120

1041551

Raster

Side

CLV620-3000

1041552

CLV620-3120

1041553

Line

Front

CLV621-0000

1041784

CLV621-0120

1041785

Raster

Front

CLV621-1000

1041786

CLV621-1120

1041787

Line

Side

CLV621-2000

1041788

CLV621-2120

1041789

Raster

Side

CLV621-3000

1041790

CLV621-3120

1041791

Line

Front

CLV622-0000

1041792

CLV622-0120

1041793

Raster

Front

CLV622-1000

1041794

CLV622-1120

1041795

Line

Side

CLV622-2000

1041796

CLV622-2120

1041797

Raster

Side

CLV622-3000

1041798

CLV622-3120

1041799

Sic k

|

C LV 6 x x b ar cod e s cann e r s e ri e s

21

Page 22

Order information, CLV63x variants.

Ty p e

CLV630

CLV631

CLV632

22

Read range

Long-range

Mid-range

Short-range

Scanning process

Read window

Standard version with 1 5 - p i n D - s u b H D p l u g

Ethernet version with 2 x M12 plug connectors

Type

Part number

Type

Part number

Line

Front

CLV630-0000

1040706

CLV630-0120

1041969

Raster

Front

CLV630-1000

1041970

CLV630-1120

1041971

Line

Side

CLV630-2000

1041972

CLV630-2120

1041973

Raster

Side

CLV630-3000

1041974

CLV630-3120

1041975

Line scanner with oscillating mirror

Side

CLV630-6000

1041976

CLV630-6120

1041977

Line

Front

CLV631-0000

1041978

CLV631-0120

1041979

Raster

Front

CLV631-1000

1041980

CLV631-1120

1041981

Line

Side

CLV631-2000

1041982

CLV631-2120

1041983

Raster

Side

CLV631-3000

1041984

CLV631-3120

1041985

Line scanner with oscillating mirror

Side

CLV631-6000

1041986

CLV631-6120

1041987

Line

Front

CLV632-0000

1041988

CLV632-0120

1041989

Raster

Front

CLV632-1000

1041990

CLV632-1120

1041991

Line

Side

CLV632-2000

1041992

CLV632-2120

1041993

Raster

Side

CLV632-3000

1041994

CLV632-3120

1041995

Line scanner with oscillating mirror

Side

CLV632-6000

1041996

CLV632-6120

1041997

C LV 6 x x b a r c o d e s c a n n e r s e r i e s | S i c k

2008-04

Page 23

Order information, CLV640 variants.

Ty p e

CLV640

Read range

Dynamic

Scanning process

Read window

Standard version with 1 5 - p i n D - s u b H D p l u g

Ethernet version with 2 x M12 plug connectors

Type

Part number

Type

Part number

Line

Front

CLV640-0000

1042014

CLV640-0120

1042015

Raster*

Front

CLV640-1000

1042016

CLV640-1120

1042017

Line*

Side

CLV640-2000

1042018

CLV640-2120

1042019

Raster*

Side

CLV640-3000

1042020

CLV640-3120

1042021

Line scanner with oscillating mirror

Side

CLV640-6000

1042022

CLV640-6120

1042023

* from Q4/2008

2008-04

S i c k | C LV 6 x x b a r c o d e s c a n n e r s e r i e s

23

Page 24

Technical Data.

Ty p e

C LV 6 2 x b a r c o d e scanners

Focus

Fixed focus

Reading field

Line/raster scanner: frontal, line/raster scanner with angle attachment: lateral (light exit below 105°)

Laser diode (wavelength)

Red light (λ = 655 nm)

MTTF of laser diode

20.000 h

Laser class of device

Class 2 acc. to IEC 60825-1 and EN 60825-1, see warning label on device for date of publication

Usable aperture

Max. 50°

Scanning/decoder frequency

400 … 1.200 Hz

Resolution

0,15 … 1,0 mm (type-dependent)

Raster height

15 mm (8 lines) at 200 mm reading distance (frontal read field)

Bar code print contrast (PCS)

≥ 60 %

Ambient light immunity

2,000 lx (on bar code)

Number of bar codes per scan

Standard decoder: 1 ... 20, SMART620 decoder: 1... 6, SMART decoder: 1 ... 6

Number of bar codes per reading gate 1)

1 … 50 bar codes (auto-discriminating)

Bar code types

Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode

Bar code length

Max. 50 symbols (max. 5,000 symbols from all bar codes per read gate, 500 symbols with Multiplexer function (CAN))

Print ratio

2:1 … 3:1

Number of multiple readings

1 … 99

Memory card for parameters (cloning)

No

Optical indicators

6 LEDs: Ready, Result, Laser, Data, CAN, LNK TX, C LV 6 3 x b a r c o d e scanners

C LV 6 4 0 b a r c o d e scanners Dynamic focus

0,15 … 1,0 mm (type-dependent)

0,2 … 1,0 mm (type-dependent)

Micro SD card (flash card), 512 MB, optional

Bar graph display

Acoustic indicators

Beeper, can be deactivated, potential function for results status indication

Control elements

No

Read cycles

Cycle sources for start: switching inputs “Sensor 1” 2) and/or “Sensor 2”; Command; Autocycle; CAN

2 buttons (Select and Start/Stop functions)

Cycle sources for stop: read cycle source, “Sensor 1”, “Sensor 2”, Command, Timer, Good Read, Condition Data interface, “Host”

24

Serial: RS-232 or RS-422/485; Ethernet (Port 2112), data format (serial) and data output format adjustable

Data transfer rate

2.4 ... 115.2 kBd

Protocol

SICK Standard (SOPAS-ET ET Cola A)

Physical configurations

Stand-alone

Data interface, “Aux”

Serial: RS-232 (57.6 kBd; 8 data bits, no parity, 1 stop bit); Ethernet (Port 2111), fixed data output format

Data interface, “Ethernet”

Only with Ethernet version: 10/100 MBit/s; TCP/IP, half/full duplex

Data interface, “CAN”

20 kBit/s ... 1 MBit/s, SICK CAN-SENSOR network (Master, Slave, Multiplexer)

Digital switching inputs 2)

Standard version: 2 Ethernet version: 1 Each version with 2 additional external inputs via CMC600

Digital switching outputs

Standard version: 2 Ethernet version: 0 Each version with 2 additional external outputs via CMC600

C LV 6 x x b ar cod e s cann e r s e ri e s |

Sic k

2008-04

Page 25

Ty p e

C LV 6 2 x b a r c o d e scanners

C LV 6 3 x b a r c o d e scanners

C LV 6 4 0 b a r c o d e scanners

Electrical connection

Standard version: cable (0.9 m) with 15-pin D-sub HD plug Ethernet version: rotating plug unit with 2 M12 round plug-in connectors (12-pin plug, 4-pin socket)

Operating voltage

10 ... 30 V DC acc. to IEC 364-441 (SELV and PELV acc. to IEC 60364-4-41)

18 ... 30 V DC acc. to IEC 364-4-41 (SELV and PELV acc. to IEC 60364-441)

Power consumption

Line/raster scanner: typically 4.5 W at 24 V DC ± 10%

Line/raster scanner: typically 5 W at 24 V DC ± 10%

Housing

Aluminium die-cast

Material, read window

Glass or plastic, see type label CLV63x-xxxy (y = 0: glass, y = 1: plastic)

Electrical safety

Acc. to EN 60950-1

Protection Class

III acc. to EN 61140

Enclosure rating

IP 65, acc. to EN 60529; A1

EMV testing

Emission of interference: acc. to EN 61000-6-3, immunity to interference: acc. to EN 61000-6-2

Vibration/impact immunity

Acc. to EN 60068-2-6/acc. to EN 60068-2-27

Weight

Standard version: 225 g with connection cable (frontal read window), Ethernet version: 205 g without connection cables (frontal read window)

Ambient/storage temperature

0 … +40 °C/–20 … +70 °C

Max. relative air humidity

90 %, non-condensing

Housing colour

SICK blue (light blue acc. to RAL 5012)

Line/raster scanner: typically 5.5 W at 24 V DC ± 10%

Standard version: 320 g with connection cable (frontal read window) Ethernet version: 250 g without connection cables (frontal read window)

1) Read gate: time window for code evaluation generated internally via read cycle 2) Ethernet version: only switching input Sensor 1.

Supplementar y technical data for oscillating mirror

C LV 6 3 x - 6 x x x b a r c o d e s c a n n e r

Read window

Lateral, light exit below 105° (basic setting)

Usable aperture angle

Max. 50°

Oscillating mirror functions

Uncontrolled operation: - fixed (adjustable position) or - continuous free oscillation Controlled operation (start and stop condition adjustable): - triggered oscillations (start position and number of oscillations adjustable) - one-shot: single oscillation in forward and backward motion (start position adjustable) The amplitude is adjustable for all oscillation modes in both directions of motion independently of one another. The oscillation speed for both directions of motions can be adjusted compared to one another within the selected period length for a complete oscillation.

Oscillation frequency / length of period

0.5 ... 6.25 Hz / 2,000 ... 160 ms

Max. amplitude

+20° ... –20°

Power consumption

Typically 6 W at 24 V DC ±10%

Weight

Standard version: 450 g Ethernet version: 350 g

2008-04

C LV 6 4 0 - 6 x x x b a r c o d e s c a n n e r

Typically 6.5 W at 24 V DC ±10%

Sic k

|

C LV 6 x x b ar cod e s cann e r s e ri e s

25

Page 26

Dimensional drawings, CLV620. Front reading window Standard version

Ethernet version

Side reading window Standard version

Ethernet version

All measurements in mm. 26

C LV 6 x x b ar cod e s cann e r s e ri e s |

Sic k

2008-04

Page 27

Dimensional drawings, CLV630/CLV640. Front reading window Standard version

Ethernet version

All measurements in mm.

2008-04

Sic k

|

C LV 6 x x b ar cod e s cann e r s e ri e s

27

Page 28

Dimensional drawings, CLV630/CLV640. Side reading window Standard version

Ethernet version

All measurements in mm.

28

C LV 6 x x b ar cod e s cann e r s e ri e s |

Sic k

2008-04

Page 29

Dimensional drawings, CLV630/CLV640 Oscillating mirror. Side reading window Standard version

Ethernet version

All measurements in mm.

2008-04

Sic k

|

C LV 6 x x b ar cod e s cann e r s e ri e s

29

Page 30

Simplify your Network! Invest in a needs-oriented network, optimise your plant performance without major cabling effort. The CLV6xx product family can be integrated in many fieldbus technologies. Ethernet and CAN interfaces are already available in the CLV6xx. Every device in the family can be used as a multiplexer in CAN-SENSOR networks. The scanners can be integrated in PROFIBUS and DeviceNet networks via external fieldbus gateways. The “2-component solution”, i.e. the CLV6xx with separate connection technology, offers further advantages: the scanner can be “buried” in the plant while the connection module remains easily accessible from outside. Result: simple parameterisation, simple cabling of the fieldbus to easily accessible locations.

CDB620 Connection Device Basic

CDM420 Connection Device Modular

CMC600 Connection Module Cloning

CMD400 Connection Module Display

30

Connector technology at a glance:

Your benefits:

• connection module for all SICK bar code scanners • connection diagram • spring-loaded contacts • 65 enclosure rating • cables

• and space savings • wiring with the periphery • investment requirement • simple troubleshooting • scanner replacement through use of CMC600

• Connection module for integration of: - Fieldbus modules - devices for power supply - module connection diagram • spring-loaded/ screw contacts • 65 enclosure rating • cables

• Comfortable network integration • memory for rapid scanner replacement • /diagnosis via display • simple mounting • troubleshooting • power provision with CMP power supply module

• parameter memory for SICK bar code scanner • and simple mounting in CDB/CDM connection modules • functionality • monitoring through visible rotary coding switch • commissioning of CAN networks

• very rapid scanner replacement if repair required • installation in existing basis devices • • additional space requirement • additional wiring effort

• illuminated display with 4 x 20 symbols • buttons for menu guidance • For CDM420/490 basis device • 65 enclosure rating

• legibility • in-situ diagnosis of scanner • PC connection required • • additional wiring effort • commissioning

C LV 6 x x b a r c o d e s c a n n e r s e r i e s | S i c k

2008-04