For the Sick CLV450 and Sick CLV440

Page 46

CLV 490 23.6 (600)

23.6 (600)

CLV 490 - Line

15.7 (400) 7.9 (200)

Scan Window

CLV 490 - Oscillating Mirror

15.7 (400) 7.9 (200)

a b

0

Scan Window a b

0 c c -7.9 (-200)

-7.9 (-200)

-15.7 (-400)

-15.7 (-400)

-23.6 (-600) 15.7 (400)

23.6 (600)

-23.6 (-600) 15.7 (400)

31.5 39.4 47.2 55.1 63.0 70.9 78.7 86.6 (800) (1000) (1200) (1400) (1600) (1800) (2000) (2200)

23.6 (600)

31.5 39.4 47.2 55.1 63.0 70.9 78.7 86.6 (800) (1000) (1200) (1400) (1600) (1800) (2000) (2200)

Reading Distance

Reading Distance Code Resolution

Code Resolution

31.5 (800)

a: 0.011 in (0.30 mm)

a: 0.011 in (0.30 mm)

b: 0.013 in (0.35 mm)

b: 0.013 in (0.35 mm)

c: 0.020 in (0.50 mm)

c: 0.020 in (0.50 mm)

CLV 490 LD - Line

23.6 (600)

Scan Window

15.7 (400)

23.6 (600)

7.9 (200)

15.7 (400)

a b

0

CLV 490 HD - Line

7.9 (200)

a c Scan Window

-7.9 (-200)

b

0 c -15.7 (-400)

-7.9 (-200)

-23.6 (-600)

-15.7 (-400)

-31.5 (-800) 15.7 (400)

-23.6 (-600) 15.7 (400)

23.6 (600)

31.5 39.4 47.2 55.1 63.0 70.9 78.7 86.6 (800) (1000) (1200) (1400) (1600) (1800) (2000) (2200)

23.6 (600)

31.5 39.4 47.2 55.1 63.0 70.9 78.7 86.6 (800) (1000) (1200) (1400) (1600) (1800) (2000) (2200)

Reading Distance Tilt a: -45°…+45°

Reading Distance

Code resolution: 0.020 in (0.5 mm)

Code Resolution a: 0.008 in (0.20 mm)

b: -30°…+30° b: 0.010 in (0.25 mm)

c: -15°…+15° c: 0.011 in (0.30 mm)

www.sickusa.com

59

800.325.7425 fixed position scanners

READING RANGES Dimensions in inches (mm)

Page 47

CLV 490 TECHNICAL SPECIFICATIONS CLV 490 Scanning Characteristics Scanning Method Aperture Angle Scanning Frequency Light Source Reading Distance (Bar Code Dependent) Resolution Bar Code Types Bar Code Symbology Readability Auto Discrimination Communications / I/O / Indicators Host Interface Baud Rate Data Format Network Configuration LED Indicators Switching Inputs Switching Outputs Trigger Methods Mechanical / Electrical Supply Voltage Current Consumption Dimensions Weight Housing / Enclosure Rating Connectivity Environmental Ambient Operating Temperature Storage Temperature Vibration Shock EMV Maximum Relative Humidity Programming

CLV 490 LD

CLV 490 HD

8-sided polygon mirror wheel Line scanner: maximum 60°; osc mirror scanner:maximum 50° 600…1200 Hz (software selectable) Visible laser diode (650 nm); CDRH Class II 19.7…82.7 in (500…2100 mm) 19.7…86.6 in (500…2200 mm) 0.012…0.078 in (0.30…2.0 mm) 0.014…0.047 in (0.35…1.2 mm)

15.7…63.0 in (400…1600 mm) 0.008…0.016 in (0.2…0.4 mm)

Code 39, Interleaved 2/5, Industrial 2/5, Codabar, Code 93, EAN/EAN 128, UPC, Code 128 1 to 40 bar codes per reading gate (standard decoder); 1 to 6 (SMART) 8 different symbologies per reading gate RS 232 or RS 422/485 variable data output (software selectable) 300…57,600 (software selectable) Data bits, stop bits, parity (software selectable) Pass-through; master/slave; RS 485 network Device ready, result, sensor, data 6 x PNP, opto-decoupled / maximum 30 V DC 4 x PNP, maximum 100 mA / 24 V DC Sensor input (I/O interface) / Serial (host interface) / Free running Operating voltage 18…30 V DC 375 mA at 24 V DC / typical 9.0 W; maximum 13.0 W Line scanner: 4.6 x 4.6 x 3.7 in (117 x 117 x 94 mm); osc mirror scanner: 7.2 x 5.02 x 3.7 in (183 x 127.5 x 94 mm) Approx. 3.3 lb (1.5 kg); with osc mirror: approx. 4.9 lb (2.2 kg) Die cast aluminum / IP 65 2 15-pin D-Sub high density connectors (1 male / 1 female) 32…104°F (0…40°C) -4…158°F (-20…70°C) To IEC 68-2-6 test FC To IEC 68-2-27 test EA To IEC 801 90%, non-condensing Windows™-based CLV Setup Software www.sickusa.com

60

800.325.7425

Page 48

CLV 490

CLV 490

CLV 490 (with heater)

CLV 490 Low Density

CLV 490 LD (with heater)

CLV 490 High Density

Line Scanner Model

CLV 490-0010

CLV 490-0011

CLV 490-6010

CLV 490-6011

CLV 490-2010

Part Number

1 016 958

1 016 960

1 018 872

1 019 095

1 019 311

Oscillating Mirror Scanner Model

CLV 490-1010

CLV 490-1011

CLV 490-7010

CLV 490-7011

CLV 490-3010

Part Number

1 016 959

1 016 961

1 019 094

1 019 096

1 019 313

PINOUTS I/O Port

Term/Host Port 15-pin male connector 1 5 6

15-pin female connector 5 10

11

15

6

15

Pin

Terminal/ Host Port

Host Communications RS 232 RS 422/485

1 2 3 4 5 6

24 V DC RxD TxD GND -

GND -

Term 422 GND RD+

7 8

-

RxD -

RDTD+

9 10 11 12 13 14

CAN H BUS RTBUS RT+ BUS RBUS R+

TxD -

TD-

15

CAN L

-

- www.sickusa.com

1

10

61

11

Pin 1 2 3 4

Signal 24 V DC IN 1 Sensor Input Result 1

Function Supply voltage Switching input (Focus Control) Switching input (Trigger) Switching output

5 6 7

GND IN 0 IN 2

Ground Switching input (Focus Control) Switching input (Focus Control)

8 9 10 11 12 13

Result 2 IN GND Result 3 IN 3 IN 4 I2C SDA

Switching output Common ground Switching output Switching input (Focus Control) Switching input (Focus Control) I2C Bus

14 15

I2C SCL Result 4

I2C Bus Switching output

800.325.7425 fixed position scanners

MODELS AND PART NUMBERS

Page 49

CLV 490 DIMENSIONAL DRAWINGS Dimensions in inches (mm) CLV 490 line scanner 0.8 (21.0)

3.1 (78.0) 0.5 (12.0)

2.2 (56.0)

Device Ready

1.5 (38.5)

Mounting holes

Sensor Read Result

4.6 (116.0)

Data

1.2 (30.0)

4.6 (117.0)

3.7 (94.0)

CLV 490 oscillating mirror scanner 3.4 (85.0)

2.7 (68.0)

max 40°

15°

1.0 (25.5)

2.0 (50.0) Mounting holes

7.1 (181.0)

4.5 (113.0)

3.7 (94.0)

4.6 (116.0)

Device Ready Device Ready Sensor Sensor Read Result Read Result Data Data www.sickusa.com

62

800.325.7425

Page 50

CLV 490 fixed position scanners

CONNECTION DRAWINGS

To PC running CLV Setup Software for programming CLV

PS 56 Cables: 7 021 851 7 021 849

KP-DB09-2E KP-DB09-3E

Terminal

Host

CLV I/O

CLV

To Term/Host port 6 010 075 KP-DB15H-2E 7 026 219 KP-DB15H-3E

(optional)

CLV 490 To Host Device for data transmission (PLC, computer, etc.) To CLV I/O port 6 010 075 KP-DB15H-2E 7 026 219 KP-DB15H-3E www.sickusa.com

63

800.325.7425

Page 51

Setup Software CLV Setup Software FEATURES • Unique scanner configuration software • Windows™-based, user-friendly format • Stand-alone operation • Direct file transfer to/from all CLV scanners • Long term file storage on disk Part Number Computer Hard Disk Space Disk Drive Memory Requirements System Software Mouse CLV Scanner Interface / Compatibility

CLV Setup Software 2 020 455 (diskette); 7 026 126 (CD) Minimum IBM 486, or true 486 IBM compatible 10 MB of available disk space One 3.5" high density drive / one CD ROM drive Recommended 8 MB RAM Windows™ 95, 98, NT or 2000 Optional but recommended CLV 210, 212, 214, 220, 230, 250, 265, 280, 295, 410, 412, 414, 420, 421, 422, 430, 431, 432, 440, 442, 450, 490, CLX 490, ICR 850 or OPS 400

CLP Setup Software FEATURES • Unique scanner configuration software • Windows™-based, user-friendly format • Stand-alone operation • Direct file transfer to/from CLP scanner • Long term file storage on disk Part Number Computer Hard Disk Space Disk Drive Memory Requirements System Software Mouse CLV Scanner Interface / Compatibility

CLP Setup Software 2 021 674 Minimum IBM 486, or true 486 IBM compatible 5 MB of available disk space One 3.5" high density drive / one CD ROM drive Recommended 8 MB RAM Windows™ 95, 98, NT or 2000 Optional but recommended CLP 100 www.sickusa.com

64

800.325.7425

Page 52

Setup Software CiMenu32™ Software fixed position scanners

FEATURES • Unique scanner configuration software • Supports serial, Starnode and Ethernet communications • Windows™-based, user-friendly format • Terminal emulator built in • Easily change a single parameter on multiple devices • Compare scanner configurations • Easily restore from one device to another • Automated Help display

Computer System Software Scanner Interface / Compatibility

CiMenu32™ Software Pentium™-class CPU Windows™ 95, 98, NT or 2000 CiMAX® 7500/7500A/7600 Series, OMNI-L Slim X, CiMAX® 6000, Scanstar 2421, OMNI-2000, OMNI-2110, MHI-2000 www.sickusa.com

65