The text of a spec sheet · part 4 of 6
Fixed Position Scanners, pages 28 to 36
Pages 28 to 36 of 52
The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV450 and Sick CLV440
Page 28
CLV 440/442
31.5 (800)
15.7 (400)
CLV 440
23.6 (600)
7.9 (200) 3.9 (100) Scan Window
Deflection Range of CLV 440 Line Scanner with Oscillating Mirror
27.6 (700)
11.8 (300)
19.7 (500)
a b
0
Deflection Range c
15.7 (400)
40° 20°
-3.9 (-100)
11.8 (300)
-7.9 (-200)
7.9 (200) 3.9 (100)
-11.8 (-300) -15.5 (-400) 0
0
3.9 (100)
7.9 11.8 15.5 19.7 23.6 27.6 (200) (300) (400) (500) (600) (700)
31.5 (800) 3.9 (100)
Reading Distance
7.9 11.8 15.7 19.7 (200) (300) (400) (500)
23.6 700 31.5 35.4 39.4 43.3 47.2 (600) (27.6) (800) (900) (1000) (1100) (1200)
Reading Distance
Code Resolution a: 0.013 in (0.35 mm) b: 0.02 in (0.50 mm) c: 0.040 in (1.0 mm)
Reading distance Resolution
1.9 (50)
3.9 (100)
CLV 442
5.9 (150)
7.9 (200)
9.8 (250)
11.8 (300)
13.8 (350)
15.5 (400)
17.7 (450)
19.7 (500)
13.8 (350)
15.5 (400)
17.7 (450)
19.7 (500)
F1
0.007 in (0.2 mm)
F2 F3 1.9 (50)
3.9 (100)
5.9 (150)
7.9 (200)
9.8 (250)
11.8 (300)
Focus Position F 1: 5.5 in (140 mm) F 2: 8.5 in (215 mm) F 3: 11.0 in (280 mm)
www.sickusa.com
41
800.325.7425 fixed position scanners
READING RANGES Dimensions in inches (mm)
Page 29
CLV 440/442 TECHNICAL SPECIFICATIONS CLV 440 Scanning Characteristics Scanning Method Aperture Angle Scanning Frequency Light Source Reading Distance (Bar Code Dependent) Resolution Bar Code Types Bar Code Symbology Readability Auto Discrimination Communications / I/O / Indicators Host Interface Baud Rate Data Format Network Configuration LED Indicators Switching Inputs Switching Outputs Trigger Methods Mechanical / Electrical Supply Voltage Current Consumption Dimensions Weight Housing / Enclosure Rating Connectivity Environmental Ambient Operating Temperature Storage Temperature Vibration Shock EMV Maximum Relative Humidity Programming
CLV 442
8-sided polygon mirror wheel Maximum 50° 300…800 Hz (software selectable) Visible laser diode (670 nm); CDRH Class II 2…31.5 in (51…800 mm) 1.2…13.4 in (30…340 mm) 0.008…0.040 in (0.2…1.0 mm) 0.005…0.013 in (0.15…0.35 mm) Code 39, Interleaved 2/5, Codabar, Code 93, EAN/EAN 128, UPC, Code 128, Pharmacode 1 to 20 bar codes per reading gate (standard decoder); 1 to 6 (SMART) 8 different symbologies per scan or reading gate RS 232 and RS 422/485, variable data output format (software selectable) 300…57,600 (software selectable) Data bits, stop bits, parity (software selectable) Pass-through; master/slave; RS 485 network; CAN Bus Device ready, result, laser on, data 2 x PNP, Opto-decoupled / maximum 30 V DC 2 x PNP, 100 mA / 24 V DC; variable pulse duration (10…990 ms) Sensor input (I/O interface) / Serial (host interface) / Free running / Reflector polling (automatic) Operating voltage 10…30 V DC Line scanner: 208 mA at 24 V DC / 5.0 W; Osc mirror: 258 mA at 24 V DC / 6.2 W Line scanner: 3.5 x 2.4 x 1.4 in (90 x 60 x 35.7 mm); Osc mirror: 3.9 x 3.6 x 1.5 in (99.8 x 92.2 x 37.8 mm) Approx. 1.0 lb (480 g) Die cast zinc / IP 65 15-pin male D-Sub high density connector 32…104°F (0…40°C) -4…158°F (-20…70°C) To IEC 68-2-6 test FC To IEC 68-2-27 test EA To IEC 801 90%, non-condensing Windows™-based CLV Setup Software www.sickusa.com
42
800.325.7425
Page 30
CLV 440/442
CLV 440 fixed position scanners
MODELS AND PART NUMBERS CLV 442
Front Emitting Line Scanner Model
CLV 440-0010
CLV 442-0010
Part Number
1 017 588
1 017 595
Oscillating Mirror Scanner Model
CLV 440-6010
-
Part Number
1 017 984
-
PINOUTS 15-pin connector 1
5
6
10
11
15
Pin 1
Signal 10…30 V
Function Supply voltage
2 3
RxD (Terminal) TxD (Terminal)
Data interface 2 (receiver) Data interface 2 (transmitter)
4 5 6 7
Sensor 2 GND RD+ (RS 422/485) RD- (RS 422/485) RxD (RS 232) TD+ (RS 422/485)
Switching input, variable function Ground Data interface 1 (receiver) Data interface 1 (receiver) Data interface 1 (transmitter)
10
TD- (RS 422/485) TxD (RS 232) CAN H
Data interface 1 (transmitter) CAN Bus (IN / OUT)
11 12 13 14 15
CAN L Result 1 Result 2 Sensor 1 Sensor GND
CAN Bus (IN / OUT) Switching output, variable function Switching output, variable function Switching input for ext. reading pulse Common ground (all inputs)
-
-
Shield
8 9 www.sickusa.com
43
800.325.7425
Page 31
CLV 440/442 DIMENSIONAL DRAWINGS Dimensions in inches (mm) CLV 440/442 front emitting scanner 1.4 (35.9)
0.2 (4) 0.4 (10)
0.6 14.4) 0.4 (10)
0.5 (13.2)
0.2 (4)
1.4 (35.9) 24
2.4 (60)
3.5 mW Pulse duration: 98 s 650 nm EN 60825-1: 1994 + A11: 1996
CLASS II LASER PRODUCT 3.5 mW Pulse duration: 49 s 650 nm Complies with 21 CFR 1040.10
C A U T I O N
LASER LIGHT - DO NOT STARE INTO BEAM
Max. Output: Wavelength:
50°
Max. output radiation: Emitted wavelength:
LASER RADIATION - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT
AVOID EXPOSURE LASER RADIATION EMITTED FROM THIS APERTURE
3.5 (90)
2.3 (59.5)
Made in Germany
CLV 440-6010 P/N: 1 017 988 S/N: 0009 3946 DC 10...30V6, 2W Manufactured: March 2000 Data
Laser On
Device Ready
9.3 (.37)
Result
Tapped blind hole, M5, 0.2 in (5 mm) deep
92.2 (3.63)
SICK AG D-79276 Reute
CLV 440 oscillating mirror scanner
35.7 (1.41)
37.8 (1.49)
10 (.39) 35.9 (1.41)
1.1 13.2 (.04) (.52) 2.5 (.1)
24.1 (.95)
4 (.16)
105° 20° 20°
90 (3.54)
99.8 (3.93)
59.5 (2.34)
www.sickusa.com
44
800.325.7425
Page 32
CLV 440/442
To PC for programming with CLV Setup Software
PS 53 Cables: 7 021 851 7 021 849
KP-DB09-2E (2 Meters) KP-DB09-3E (3 Meters)
CLV 440/442
Terminal
Host
CLV
(optional)
To Host Device for data transmission (PLC, computer, etc.) Optional Extension Cable: 6 010 075 KP-DB15H-2E www.sickusa.com
45
800.325.7425 fixed position scanners
CONNECTION DRAWINGS
Page 33
CiMAX® 7500A/7550A/7555A FEATURES • Up to 1200 Hz • “C” programmable • Factory configured to meet specific applications needs • Minimizes post-processing of data • Open architecture, connects to factory network • SDS, DeviceNet and Ethernet connectivity • CIX® (Code Information eXtraction) Technology • Integrated scanner and decoder
Model
Optics Type
Reading Range
Bar Code Resolution
Scan Frequency
CiMAX 7500A
Standard
2.0…38.0 in (51…965 mm)
0.008 in (0.20 mm)
1200 Hz
CiMAX 7550A
Standard
2.0…38.0 in (51…965 mm)
0.008 in (0.20 mm)
1200 Hz
CiMAX 7555A
Standard
2.0…38.0 in (51…965 mm)
0.008 in (0.20 mm)
1200 Hz
Scan Options*
Focus Type
Decoding Method**
Housing/Enclosure*
Line Raster Oscillating Mirror
Fixed Focus Focus Control Dynamic Focus Control
Standard PCX CIX
Front Emitting Side Emitting Oscillating Mirror
**user selectable
*ordered separately
*ordered separately www.sickusa.com
46
800.325.7425
Page 34
CiMAX® 7500A/7550A/7555A
16.0 (406)
8.0 (203)
CiMAX® 7500A 8 in diode
6.0 (152)
8.0 (203)
4.0 (102)
4.0 (102)
2.0 (51) Scan Window
CiMAX® 7500A 14 in diode
12.0 (305)
a
Scan Window
0 a
-2.0 (-51)
-4.0 (-102)
b
-4.0 (-102)
-8.0 (-203)
-6.0 (-152)
-12.0 (-305)
0 b
-8.0 (-203)
0
1.0 (25)
2.0 (51)
3.0 (76)
4.0 5.0 6.0 7.0 (102) (127) (152) (178)
8.0 9.0 10.0 11.0 12.0 (203) (229) (254) (279) (305)
-16.0 (-406)
0
2.0 (25)
4.0 (102)
8.0 10.0 12.0 14.0 6.0 (152) (203) (254) (305) (356)
16.0 18.0 20.0 (406) (457) (508)
Reading Distance
Reading Distance
Code Resolution
Code Resolution a: 0.010 in (0.25 mm)
a: 0.010 in (0.25 mm)
b: 0.015 in (0.38 mm)
b: 0.015 in (0.38 mm)
16.0 (406) 12.0 (305)
CiMAX® 7500A 20 in diode
8.0 (203) 4.0 (102) Scan Window a
0 b c
-4.0 (-102) -8.0 (-203) -12.0 (-305) -16.0 (-406) 4.0 6.0 (102) (152)
8.0 10.0 (203) (254)
12.0 (305)
14.0 16.0 18.0 20.0 22.0 (356) (406) (457) (508) (559)
24.0 26.0 28.0 30.0 32.0 (610) (660) (711) (762) (813)
Reading Distance
Code Resolution a: 0.010 in (0.25 mm) b: 0.015 in (0.38 mm) c: 0.035 in (0.89 mm)
www.sickusa.com
47
800.325.7425 fixed position scanners
READING RANGES Dimensions in inches (mm)
Page 35
CiMAX® 7500A/7550A/7555A TECHNICAL SPECIFICATIONS 7500A Scanning Characteristics Aperture Angle* Scanning Frequency* Light Source* Reading Distance (Bar Code Dependent)* Maximum Depth of Field Resolution* Bar Code Types Bar Code Symbology* Communications / I/O / Indicators Communications LED Indicators Switching Inputs Switching Outputs Trigger Methods Setup Diagnostics Process Control Mechanical / Electrical Current Consumption Dimensions (L x W x H) Weight Housing / Enclosure Rating Connectivity Environmental Ambient Operating Temperature Relative Humidity Programming
7550A/7555A
Maximum 60° 1200 Hz Visible laser diode (670 nm); CDRH Class II 2.0…38.0 in (51…965 mm) 36.0 in (914 mm) 0.008 in (0.20 mm) Code 39, Interleaved 2/5, Codabar, Code 93, EAN, UPC, Code 128 1 asynchronous serial host port RS 422/232; 1 asynchronous serial terminal port RS 232; 1 LAN port with Starnode protocol RS 485; 1 Ethernet port 10 base 2 connection (optional)/SDS/DeviceNet™ Setup, Presence, Decode, XMIT/RCV, I/O, Power/Laser On 8 x PNP, opto-decoupled / maximum 30 V DC 8 x PNP, maximum 150 mA / 30 V DC Sensor input (I/O interface) / Serial (host interface) / Free running Via terminal port using CiMAX® 1400 or PC 32-bit processor with 256 K/1 MB non-volatile RAM, “C” programmable 12 V DC ± 5%, 1…5 A, 12 V DC ± 5%, 1A, 5 V DC ± 5%, 1 A (with Ethernet) 4.5 x 4.31 x 5.75 in (114 x 109 x 146 mm) 7.0 x 4.31 x 5.75 in (178 x 109 x 146 mm) Approx. 3.5 lb (1.6 kg) Approx. 4.4 lb (2.02 kg) Epoxy powder-coated aluminum, NEMA 12 / IP 65 dust and drip proof 2 9-pin D-Sub connectors (1 male / 1 female), 1 25-pin D-Sub connector (female) 32…122° F (0…50° C) 5…95%, non-condensing Windows™-based CiMenu32™ Software
*Actual operational specifications are optimized for each application during factory configuration
Options • CIX® Technology • Ethernet Interface • 16-side polygon discrete raster • Interface box with provisions for isolation and connections to Opto-22 style solid state relays www.sickusa.com
48
800.325.7425
Page 36
CiMAX® 7500A/7550A/7555A CiMAX 7500A
CiMAX 7550A
CiMAX 7555A
Model Configuration*
7500A-A B C D E F
7550A-A B C D E F
7555A-A B C D E F
Part Number
*
*
*
Front Emitting Line Scanner
*See possible scanner configurations in Part Numbers and Accessories section, pages 128-131.
PINOUTS 25-pin female connector
9-pin male connector Host
I/O
13
1
9
25
14
Pin
Signal
Pin
Signal
1 2
Host T422+ Host RxD
3 4
Host TxD Setup RxD
1 2 3
Input 1 (INZONE PRESENCE) Input 2 (OUTZONE PRESENCE) Input 3 (TACHOMETER)
5
Ground
4 5
Input 4 (HEIGHT SENSOR 1) Input 5 (HEIGHT SENSOR 2)
6 7
Host T422Host R422+
6 7
Input 6 (HEIGHT SENSOR 3) Input 7 (HEIGHT SENSOR 4)
8 9
Setup TxD Host R422-
8
Input 8 (HEIGHT SENSOR 5)
9 10
Output 1 (NO READ) Output 2 (MATCH)
11 12
Output 3 (NO MATCH) Output 4 (BEEPER)
13 14
Output 5 Output 6
15 16 17 18 19
Output 7 Output 8 Laser control Frame Ground 12 V DC
20 21 22
12 V DC Ground Ground
23 24 25
Ground 5 V DC 5 V DC
1
5
6
9-pin female connector 5
1
9
Starnode/Setup
6
Pin 1 2
Signal LAN+ (blue wire) TERM DETECT
3 4 5
LAN- (white wire) Ground Frame Ground (cable shield)
6 7 8 9
Ground TERM RxD TERM TxD 5 V DC, 500 mA max www.sickusa.com
49
800.325.7425 fixed position scanners
MODELS AND PART NUMBERS