The text of a manual · part 20 of 22

CLV 43x / 44x Bar Code Scanner Operating Instructions: 10 Appendix, pages 167 to 176

Pages 167 to 176 of 194, from CLV 43x / 44x Bar Code Scanner Operating Instructions

The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV430, Sick CLV431, Sick CLV432, Sick CLV442 and Sick CLV440

Page 167

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

8.

Click the SW-TRIGGER OFF button or press [F8]. The CLV confirms that the read was successful by emitting a tone and then ends the reading interval. Match code 1 is now stored in the RAM.

9.

Close the switch to reconnect the power supply to the "Sensor 2" switching input. The CLV saves match code 1 (code type, code length, and data content) permanently in the parameter set stored in the EEPROM. It compares every bar code it reads with match code 1 until the power supply is switched off. In doing so, it outputs the result of the comparison via the "Result 2" output and "Result" LED with the predefined pulse length.

10. Keep the switch closed. The CLV will activate teach-in mode again if you open the switch! Replacing the match code: To replace the current match code 1 with a new match code using the teach-in method, simply repeat Steps 5 to 9. Checking the programmed match code in the CLV: 1.

Switch the power supply of the connection module (of the CLV) off and on again.

2.

Perform an upload from the CLV. This is done by clicking

3.

The code type and data content of match code 1 are shown in the CODE COMPARISON group on the DEVICE CONFIGURATION tab.

in the toolbar.

Resetting the reading pulse: 1.

Select the DEVICE CONFIGURATION tab.

2.

Click the EDIT READING TRIGGER button.

3.

Click the current option in the MODE group on the dialog box.

4.

Perform a download to the CLV. This is done by clicking

5.

Confirm the dialog box by selecting the PERMANENT save option. The CLV then uses the reading pulse type that was set before the teach-in procedure.

in the toolbar.

b) Static teach-in procedure Configuring the static teach-in procedure: 1.

Select the DEVICE CONFIGURATION tab.

2.

Click the STATIC WITHOUT PHARMACODE, or STATIC WITH PHARMACODE to read a Pharmacode, in the TEACH-IN group.

3.

If necessary, click the WITH COUNTER RESET option in the COUNTER RESET group.

4.

From the ASSIGNMENT SENSOR 2 drop-down list, choose the MATCHCODE TEACH-IN option.

5.

If necessary proceed as follows to activate the output filter in the CODE COMPARISON group: – Click the CODE #1 ACTIVE checkbox. – Click the FILTER FOR OUTPUT checkbox. – Click the CODE #1 ACTIVE checkbox again. The code comparison is now no longer permanently activated. The output filter, however, remains active.

8 008 568/K949/10-06-2002

6.

Click the EDIT RESULT OUTPUTS button.

7.

In the dialog box under RESULT FUNCTIONS, choose MATCH 1 in the drop-down list for Result 2 ("Result" LED).

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-51

Page 168

Appendix

Chapter 10

Operating instructions CLV 43x/44x Bar Code Scanner

8.

Perform a download to the CLV. This is done by clicking

9.

The DOWNLOAD PARAMETERS dialog box is then displayed.

in the toolbar.

10. Confirm the dialog box by selecting the PERMANENT save option. Note

Before you can use the static teach-in method, the parameter set in the RAM and EEPROM of the CLV must be identical. This is done with the PERMANENT saving option. If you select the TEMPORARY option instead, the CLV loads the default setting after the teach-in function has been carried out and the power supply switched off. Carrying out the static teach-in procedure: 1.

Click in the toolbar. The Terminal Emulator is launched. The CLV is in Reading mode.

2.

Close the switch to connect the power supply to the "Sensor 2" switching input.

3.

Click PARAMETERIZE under DEVICE MODE. The CLV switches to Parameter mode.

4.

Click READING MODE under DEVICE MODE. The CLV returns to Reading mode and polls the condition of the "Sensor 2" switching input. It also activates code comparison at this time.

– or – As an alternative to steps 3 and 4, switch the power supply to the connection module (CLV) off and on again. The CLV outputs two consecutive tones to indicate that it has switched to Reading mode. 5.

Open the switch to interrupt the power supply to the "Sensor 2" switching input. The CLV activates teach-in mode for match code 1. It starts the reading interval automatically and waits for the match code.

6.

Present the match code. The CLV confirms that the read was successful by emitting a tone and then ends the reading interval. Match code 1 is now stored in the RAM.

7.

Close the switch to reconnect the power supply to the "Sensor 2" switching input. The CLV saves match code 1 (code type, code length and data content) permanently in the parameter set stored in the EEPROM. It compares every bar code it reads with match code 1 until the power supply is switched off. In doing so, it outputs the result of the comparison via the "Result 2" output and "Result" LED with the predefined pulse length. If the CLV was not able to read the match code, the reading interval is terminated when the switch is closed. The previously set code configuration remains intact.

8.

Keep the switch closed. The CLV will activate teach-in mode again if you open the switch!

Replacing the match code: To replace the current match code 1 with a new match code using the teach-in method, simply repeat Steps 5 to 7. Checking the programmed match code in the CLV: Proceed as described in Steps 1 to 3 in "a) Dynamic teach-in procedure", Page 10-50. Activating/deactivating the code comparison via the "Sensor 2" switching input •

10-52

Prerequisite: assignment of the MATCHCODE TEACH-IN function to the "Sensor 2" switching input

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 169

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

Activating the code comparison function: 1.

Close the switch before switching on the power supply to the CLV.

2.

Switch on the power supply. The CLV activates the code comparison function.

3.

Do not open the switch while the CLV is starting up.

Deactivating the code comparison function: 1.

Switch off the power supply to the CLV.

2.

Open the switch.

3.

Switch on the power supply. The CLV starts Reading mode without the code comparison.

Assigning result functions to the "Result 1", "Result 2" ("Result" LED) switching outputs and beeper CLV can output the result of the code comparison in the following functions: –

No match (code does not match either match code)

–

Match 1 (matches match code 1)

–

Mismatch 1 (does not match match code 1)

–

Match 2 (matches match code 2)*)

–

Mismatch 2 (does not match match code 2)*)

–

Match 1 or 2 (matches match code 1 or 2)

–

Match 1 and 2 (matches match code 1 and 2)*)

*)

only relevant if match code 2 is active

When configuring the Teach-in function for match code 1, define the following settings: 1.

Select the DEVICE CONFIGURATION tab.

2.

Click the EDIT RESULT OUTPUTS button.

3.

Choose the required option for Result 1, Result 2 and beeper from the RESULT FUNCTIONS drop-down list.

4.

Perform a download to the CLV. This is done by clicking in the toolbar. Confirm the dialog box by choosing the PERMANENT storage option.

10.9.2

Auxiliary input via terminal interface

If the CLV cannot read a bar code in Reading mode (e.g. if there is no bar code on the object), the data content of the bar code can be sent subsequently to the host by using the "Auxiliary input" function. In this way, the sequence of reading results can be completed if necessary. The auxiliary input function uses the terminal interface of the CLV exclusively and features two options: •

Manual entry of the data content via the keyboard of a connected terminal or PC (Terminal Emulation function)

•

Entry of the bar code using a handheld reader. Forwarding to the CLV via an internal or external decoder of the device

Fig. 10-34 shows the flow of auxiliary input.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-53

Page 170

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

Data content + status ST = 7

Data content

Fig. 10-34: Auxiliary input via the terminal interface of the CLV

The CLV sends the data content of the bar code that it receives via the terminal interface to the host in the same format as the other reading results on the host interface. Each string can contain the data content from a bar code with a maximum length of 50 characters. The CLV automatically enters the status ST = 7 if the error status has been enabled for transfer. The values of the other reading diagnosis data in the data string are of no significance. To enable the CLV to receive the data content of the bar code on the terminal interface, you must switch the operating mode on the interface to "auxiliary input". 1.

Connect the PC to the terminal interface (port) of the CLV using an RS 232 data connection cable (AMV/S 40: connect the PC to the internal, 9-pin "Service" plug). See Chapter 5.5.6 "Connecting the PC", Page 5-6.

2.

Start "CLV Setup" on your PC. See Chapter 10.4.3 "Starting "CLV Setup"", Page 10-29.

3.

Choose the AUXILIARY INTERFACE tab.

4.

Choose the AUXILIARY INPUT option from the drop-down list.

5.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

6.

Confirm the dialog box by selecting the TEMPORARY save option.

in the toolbar.

The terminal interface then operates temporarily in "Auxiliary Input" mode. Entering bar code using the Terminal Emulator in CLV Setup

10-54

1.

Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.

2.

Click the EXTENDED radio button in the TERMINAL MODE group. The start and stop characters used by the Terminal Emulator are displayed at the top of the screen, on the left and right of the text input field. Fig. 10-35 shows the Terminal Emulator window in extended mode.

3.

Use the drop-down list to set the start and stop characters to NUL.

4.

Enter the data content of the bar code (character string) via the keyboard. Use the backspace key to correct input errors. The data content may not contain control characters.

5.

Press [RETURN] or [ENTER]. The CLV then interprets all further characters as a new data string.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 171

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

CLV Setup sends the character string to the CLV and deletes the entry in the text field. The CLV does not send an echo. 6.

Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.

Fig. 10-35: CLV Setup: auxiliary input via the Terminal Emulator

Entering a bar code using a terminal/PC keyboard 1.

Connect the terminal / PC with Terminal Emulation program to the terminal interface on the CLV (via AMV/S 40). For the pin assignment, see Chapter 5.5.6 "Connecting the PC", Page 5-6.

2.

Set the communication parameters and data output format as shown in Table 10-9.

Parameter

Value

Data transmission rate

9 600 bits/s

Data bits

8

Parity

None

Stop bits

1

Data output format

Data terminator e.g. 1234 CR

Table 10-9: Communication parameter settings for the terminal/PC for the auxiliary input

8 008 568/K949/10-06-2002

3.

Enter the data content of the bar code via the keyboard. The terminal sends the individual characters to the CLV immediately. Use the backspace key to correct input errors.

4.

Terminate the data content with the control character [CR]. The CLV then interprets all further characters as a new data string. The CLV ignores other control characters. The data content itself may not contain any control characters.

5.

Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-55

Page 172

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

Entering bar codes using a handheld scanner with decoder 1.

Connect the handheld scanner with decoder to the terminal interface of the CLV (via AMV/S 40). For the pin assignment, see Chapter 5.3 "Connector pin assignment", Page 5-2.

2.

Set the data format and communication parameters on the handheld scanner as shown in Table 10-9.

3.

Read the bar code with the handheld scanner. Once the active reading pulse has ended, the CLV sends the data received from the PC to the host via the host interface.

If you are using the ST 1100 decoder from SICK, for example, set the communication parameters and data output as shown in Table 10-10. Parameter

Value

Terminal ID

Unassigned

WA Network

No

ACK/NAK

No

Baud rate

9 600 bits/s

Data bits

7

Parity

Space

Configuration

RS 232

Preamble (Header)

Clear

Postamble (Terminator)

CR

Table 10-10: Communication parameter settings for the ST 1100 decoder

10.9.3

Structure of a daisy chain configuration (data forwarding or master/slave arrangement)

See Technical Information "Master/Slave with Bar Code Scanners from the CLV Series" (order no. 8 007 675, English edition) 10.9.4

Structure of a SICK network (RS 485)

See "CLX 200 Network Controller" Technical Description (order no. 8 007 157, German/English edition) 10.9.5

Connection to Profibus DP

See "BMV/BMH 10 for Profibus DP" Operating Instructions (order no. 8 008 825, English edition) 10.9.6

Connection to DeviceNet

See "BMV/BMH 10 for DeviceNet" Operating Instructions (order no. 8 008 972, English edition) 10.9.7

Connection to Interbus S

See "BMS 10/20 for Interbus S" Technical Information (order no. 8 007 546, English edition) 10.9.8

Connection to Ethernet

See "BMV/BMH 10 for Ethernet" Operating Instructions (order no. 8 008 398, English edition)

10-56

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 173

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

10.9.9

Structure of a CAN scanner network

See "Application of the CAN interface" Operating Instructions (order no. 8 009 180, English edition)

10.10 Replacing a CLV (copying the parameter set) There are two methods of replacing a CLV and transferring the current parameter set to the new device: •

By using the profile bar codes

•

By downloading the parameters from CLV Setup

The parameter set can only be transferred between identical device types (e.g. from one CLV 430 to another CLV 430 etc.). 10.10.1 Transferring the parameter set using the profile bar codes To transfer the parameter set using the profile bar codes, you do not need to connect the device to a PC. The parameter set of the CLV that is to be replaced must be available in the form of archived profile bar codes or at least as a configuration file in CLV Setup. Otherwise, the replacement device must be configured from scratch. The procedure for printing out the profile bar codes is described in Chapter 10.5.2 "Profile programming", Page 10-37. 1.

Disconnect the power supply to the AMV/S 40 Connection Module (of the CLV).

2.

Disconnect the CLV plug from the AMV/S 40.

3.

Remove the CLV from the bracket. Before doing so, mark the position and alignment on the bracket/station.

4.

Install, align, and connect the replacement device.

5.

Switch on the power supply to the AMV/S 40. The "Device Ready" LED lights up. The CLV outputs a tone to indicate that it is ready to read the profile bar codes.

6.

Present the first profile bar code within 5 seconds. The CLV confirms that the bar code has been read successfully by outputting a tone via the beeper and waits 10 seconds for the next profile bar code.

7.

Present all of the other profile bar codes consecutively in the printed sequence.

8.

Then allow the final wait time (10 seconds) to elapse. The CLV outputs two consecutive tones to indicate that it has switched to Reading mode.

The new CLV is now ready to use the transferred parameter set. Troubleshooting If the software version on the replacement device is older than the version on the old device (e.g. new device is from warehouse stock), the profile bar codes may contain coded parameters or parameter values that cannot be interpreted by the older software. The CLV, however, reads all of the profile bar codes. But this does not indicate that the CLV can use all the parameters or parameter values.

¾ Use the CLV Setup program to check whether the new CLV is functioning correctly. To do so, connect the PC to the terminal interface on the CLV. Check whether all of the parameter settings used are necessary to configure the CLV for the current reading application. If necessary, replace the software version in the new device.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-57

Page 174

Chapter 10

Appendix

Operating instructions CLV 43x/44x Bar Code Scanner

If the software version on the new device is more recent than that on the old one, the default setting in the imported parameter set will include parameters that were not contained in the old version.

¾ Upload the parameter set with the CLV Setup program and check whether the new parameters are relevant for configuring the CLV for the current reading application. If necessary, change the parameter values and download the parameter set to the CLV again. Save the new parameter set as a configuration file in CLV Setup and print it out as profile bar codes for archiving purposes. See also Chapter 10.4.8 "Unknown parameters", Page 10-33. 10.10.2 Downloading the parameter set To download the parameter set, you must connect a PC running the CLV Setup software to the replacement device. The parameter set of the CLV that is to be replaced must be available as a configuration file in CLV Setup, otherwise the device must be configured from scratch. 1.

Disconnect the power supply to the AMV/S 40 Connection Module (of the CLV).

2.

Disconnect the CLV plug from the AMV/S 40.

3.

Remove the CLV from the bracket. Before doing so, mark the position and alignment on the bracket/station.

4.

Install, align, and connect the replacement device.

5.

Connect the PC to the terminal interface (port) of the CLV using an RS 232 data connection cable. (AMV/S 40: connect the PC to the internal, 9-pin "Service" plug). See Chapter 5.5.6 "Connecting the PC", Page 5-6.

6.

Switch on the power supply to the AMV/S 40. Once the CLV has started, it outputs an acoustic signal to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two acoustic signals to indicate that it has assumed Reading mode. The "Device Ready" LED lights up.

7.

Switch on the PC and start Windows.

8.

Start "CLV Setup". If the communication parameters on the PC and CLV are identical, CLV Setup uploads the parameter set from the CLV and displays the values on the tabs.

9.

Open the archived parameter set as a configuration file "*.scl" in CLV Setup and download it to the CLV.

10. Confirm the dialog box by choosing the TEMPORARY storage option. 11. Check whether the CLV reads the bar codes correctly. Correct the parameter settings if necessary. 12. Finally, download the tested parameter set to the CLV and save it with the PERMANENT storage option. The parameter set is transferred permanently to the replacement device. 13. Save the modified parameter set as a new configuration file in CLV Setup.

10-58

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 175

Operating instructions

Appendix

Chapter 10

CLV 43x/44x Bar Code Scanner

Troubleshooting If the software version on the replacement device is older than the version on the old device (e.g. new device is from warehouse stock), the parameter set transferred may contain coded parameters or parameter values that cannot be interpreted by the older software. The new device, however, outputs an error message in CLV Setup for each of these parameters/values when the parameter set is downloaded.

¾ Check whether all of the parameter settings used are necessary to configure the CLV for the current reading application. If necessary, replace the software version in the new device. If the software version on the new device is more recent than that on the old one, the default setting in the imported parameter set will include parameters that were not contained in the old version.

¾ Upload the parameter set and check whether the new parameters are relevant for configuring the CLV for the current reading application. If necessary, change the parameter values and download the parameter set to the CLV again. Save the new parameter set as a configuration file in CLV Setup. See also Chapter 10.4.8 "Unknown parameters", Page 10-33.

10.11 Accessories 10.11.1 Installation accessories Part No.

Description

Fig.

2 020 410

Mounting bracket with installation accessories

Fig. 10-36, Page 10-62

2 022 564

Mounting bracket (hoop shaped), with installation accessories

Fig. 10-37, Page 10-62

2 023 691

Round rod bracket for round rods and tubes with a diameter of 12 to 20 mm, with installation accessories

Fig. 10-38, Page 10-63

Table 10-11: Accessories: installation accessories

10.11.2 Connection modules Part No.

Type

Description

1 017 132

AMV 40-011

Connection module for CLV 43x/44x with 15-pin D-Sub HD device socket, terminal strips (signal distributors) for wiring the data and functional interfaces, internal 9-pin D Sub "Service" plug, cable grips, polycarbonate housing, enclosure rating max. IP 54. Operating voltage 10 to 30 V DC

1 017 135

AMS 40-013

As AMV 40-011 with additional integrated 230 V AC 50 Hz/24 V DC power supply

1 017 136

AMS 40-012

As AMV 40-011 with additional integrated 115 V AC 50/60 Hz/24 V DC power supply

1 017 385

AMS 40-023

As AMS 40-013, with additional 2-row LCD

2 020 825

–

Interface converter RS 422 on CL 20 mA, for a CLV; for optional installation in the AMV 40-011, AMS 40-013, AMS 40-012 and AMS 40-023

1 019 160

AMV 70-081

Connection module for CLV 43x/44x with 15-pin D-Sub HD device socket, spring-resistance terminals (signal distributors) for wiring the data and functional interfaces, internal 9-pin D-Sub "Service" plug, plastic cable screwed connections, polycarbonate housing, enclosure rating max. IP 30. With address function for network operation, operating voltage 10 to 30 V DC

6 021 105

AMV 100-011

Universal connection module for max. two CLV 43x/44x, each with a 15-pin D-Sub HD device socket, terminal strips (signal distributors) for wiring the data and functional interfaces, two internal 9-pin D-Sub "Service" plugs, cable grips, pressed aluminum housing, enclosure rating max. IP 54 (enclosure rating max. IP 65 with a plug hood), operating voltage 10 to 30 V DC

Table 10-12: Accessories: connection modules

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-59

Page 176

Appendix

Chapter 10

Operating instructions CLV 43x/44x Bar Code Scanner

Part No.

Type

Description

6 021 106

AMV 200-011

As AMV 100-011, but for max. four CLV 43x/44x

6 007 655

–

Power cable, 3-wire, length 2 m, with 3-pin connector (grounding) and one open end (stripped)

Table 10-12: Accessories: connection modules

10.11.3 Bus connection modules Part No.

Type

Description

6 020 896

BMV 10-0111

Bus connection module for connection of max. two CLVs to a Profibus DP; for the CLV 43x/44x with a 15-pin D-Sub HD device socket. With 9-pin D-Sub socket for the bus, terminal strips (signal distributors) for wiring the RS 232 data interface and the functional interfaces, two internal 9-pin D-Sub "Service" plugs, cable grips, die-cast aluminum housing, enclosure rating max. IP 54 (protection type max. IP 65 with plug hood), operating voltage 20 to 30 V DC

6 020 893

BMH 10-0111

Bus module for connection of a CLV to Profibus DP, with terminal screws, a 9-pin D-Sub socket for the bus, no housing, for top-hat rail installation, enclosure rating max. IP 20, operating voltage 10 to 30 V DC

6 021 190

BMV 10-0311

Bus connection module for connection of max. two CLVs to the DeviceNet, terminal strip for the bus connection, otherwise as with BMV 10-0111

6 021 188

BMH 10-0311

Bus module for connection of a CLV to the DeviceNet, otherwise as with BMH 10-0111

1 012 672

BMS 10-0113

Bus connection module for connection of a CLV to an Interbus S, for the CLV 43x/44x with a 15-pin D-Sub HD device socket. With two 9-pin bus connections (in/out), terminal strips (signal distributors) for wiring the data and functional interfaces, internal 9-pin D-Sub "Service" plug, integrated 230 V AC 50 Hz/24 V DC power supply, cable grips, enclosure rating max. IP 54

1 012 680

BMS 10-0112 as BMS 10-0113, but with integrated 115 V AC 50/60 Hz/24 V DC power supply

6 025 757

BMV 10-0411

Bus connection module for connection of max. two CLVs to Ethernet. TCP/IP communication, data transmission rate 10 Mbit/s. For the CLV 43x/44x with a 15-pin D-Sub HD device socket. With an 8-pin RJ 45 bus socket, terminal strips (signal distributors) for wiring the RS 232 data interface and the functional interfaces, two internal 9-pin D-Sub "Service" plugs, cable grips, die-cast aluminum housing, enclosure rating max. IP 54 (enclosure rating max. IP 65 with plug hood), operating voltage 20 to 30 V DC

6 025 756

BMH 10-0411

Bus module for connection of a CLV to Ethernet . TCP/IP communication, data transmission rate 10 Mbit/s. With terminal screws, an 8-pin RJ 45 bus socket, no housing, for top-hat rail installation, enclosure rating IP 20, operating voltage 10 to 30 V DC

6 022 140

BMV 10-0431

As with BMV 10-0411, but with FTP communication, data transmission rate 10/100 Mbit/s

6 025 748

BMH 10-0431

As with BMH 10-0411, but with FTP communication, data transmission rate 10/100 Mbit/s

6 007 655

Power cable, 3-wire, length 2 m, with 3-pin connector (grounding) and one open end (stripped)

Table 10-13: Accessories: bus connection modules

10-60

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002