Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Sick CDB410 Manual

Manual · Sick

Sick CDB410 Manual

Manual4 pagesPDF 345 KB

All 4 pages are below, each with its text.

Download the PDF345 KB

Covers · 1 model

The models it covers

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Four pages of operating instructions in German and English for the SICK CDB410, a small connection module that links a CLV41x bar code scanner to a host, peripheral devices and power. It covers installation, the configuration switches and LEDs, wiring, technical data, accessories and troubleshooting.

Device
Compact connection module for one CLV41x bar code scanner p. 1
Power supply
6 to 30 V DC, SELV or PELV p. 3
Connections
15-pin D-Sub HD socket for the scanner; internal 9-pin AUX connector (RS 232) for a PC; terminals for host, switching I/O, power and shield p. 1, 3
Power consumption
Max. 3 W with a CLV41x connected (125 mA at 24 V DC) p. 3
Indicators
5 LEDs: Power (green); Sensor 1, 2 and Result 1, 2 (yellow) p. 2, 3
Operating temperature
0 to +40 °C (+32 to +104 °F); storage -20 to +70 °C p. 3
Part number
CDB410-001 (No. 1023813) p. 3
Host cable length
Recommended max. from CLV41x to host: RS 232 up to 10 m, RS 422 up to 1,200 m, depending on data rate p. 2
Accessory cables
6010075 extension cable for CLV41x, 2 m, shielded; 2014054 RS 232 null modem cable, 3 m, for the AUX plug; 6005695 twisted-pair data cable, bought to size p. 3
Gasket
4038847 IP 65 gasket between scanner cable and extension cable p. 3
Fuse
Glass tube fuse 0.8 A, type T p. 3
Wire sizes
Screw terminals 0.14 to 2.5 mm2 (approx. 26 to 13 AWG); spring terminals 0.14 to 1 mm2 (approx. 26 to 17 AWG) p. 3
Cable glands
4, for cables 4.5 to 10 mm (0.18 to 0.39 in) p. 3
Weight
Approx. 250 g (approx. 8.75 oz) p. 3

What this manual walks you through

  • Setting the configuration switches S 1, S 3, S 5, S 6 and S 7 p. 2
  • Reading the Power, Sensor and Result LEDs p. 2
  • Wiring the module and closing unused bushings p. 2, 3
  • Connecting a PC to configure the CLV41x through the AUX connector p. 3
  • Troubleshooting power, host data, reading clock sensor and PC access p. 4
  • Mounting holes and housing dimensions p. 1, 4

Good to know

  • The customer's power supply output must be safely isolated from its input by double insulation and a safety isolating transformer. p. 2
  • Connect or release wiring only with the power off. p. 2
  • Do not lay the cables parallel to power supply or motor cables. p. 3
  • With extension cables, the CDB410 to CLV41x cable may be at most 10 m (32.8 ft) because of the RS 232 interface. p. 1
  • The manual states UL certification only when a Class 2 power supply according to UL 1310 is used. p. 1

Questions this manual answers

What voltage does the SICK CDB410 need?

6 to 30 V DC (SELV or PELV); it draws max. 3 W with a CLV41x connected. p. 3

Why does the CDB410 Power LED not light up?

Set switch S 1 (Power) to ON. p. 4

How do I connect a PC to a CLV41x through the CDB410?

Connect the PC to the internal 9-pin AUX connector and set switch S 5 to its AUX position; the RS 232 null modem cable 2014054 fits that plug. p. 3

How do I set the CDB410 to RS 485?

Set switch S 6 to ON; OFF, the default, selects RS 422. p. 2

What is the part number of the CDB410?

CDB410-001, No. 1023813. p. 3

The file

Size and text

Pages4
PDF345 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Sick CDB410 Manual

The text of page 1, from the PDF itself

AUX.. .. .. .. .CDB410“Host2“PCCLV41x CDB410 “Host“

Lichtschranke (Lesetakt)

“Result 1“ “Result 2“

Photo reflex switch (Reading clock)

“Sensor 1“

Schalter/switch Teach-in matchcode

“Sensor 2“

“Result 3“

HOST SPS/PLC SPS/PLC SPS/PLC

6 to 30 V DC

Connection Module for CLV41x Bar Code Scanner

Anschlussmodul für Barcodescanner CLV41x Be t r i e b s a n l e i t u n g

O p e r a t i n g

I n s t r u c t i o n s

1. Produkteigenschaften

1. Features

Kleines Anschlussmodul zum Anschluss eines CLV41x an Host, Peripherie und Stromversorgung

  • 9-pol. D-Sub-Stecker intern, für Anschluss der Hostschnittstelle 2 (RS-232) an PC zur Konfiguration/Diagnose des CLV41x
  • Klemmen für Hostschnittstelle, Schaltein- und -ausgänge, Stromversorgung, Schirmung
  • Von außen sichtbar: LEDs zur Anzeige von aktiven Schaltein- und -ausgängen sowie Schalterstellungen der Modulkonfiguration
  • Schutzart IP 65
  • Montierbar bei geschlossenem Deckel
  • Wartungsfrei
  • UL-zertifiziert bei Verwendung eines Class 2-Netzgerätes (geprüft nach UL 1310) zur Stromversorgung

Weitere Produktinformationen, Programm „CLV-Connect“:

Further Product Information, ”CLV-Connect” PC Program:

¾ Siehe www.sick.com

¾ See www.sick.com

EG-Konformitätserklärung:

EC Conformity Declaration
¾ Auf Anforderung

¾ On request

2. Voraussetzungen zur Installation und Inbetriebnahme

2. Installation and Commissioning Requirements

Anschlusspläne in CLV-Connect (auf CD „Manuals & Software Bar Code Scanners“, die dem Barcodescanner beiliegt, oder via Internet www.sick.com)

  • Versorgungsspannung DC 24 V, erzeugt nach IEC 742

3. Montage

3. Installation

Freier Zugang zum internen Stecker „AUX“ erforderlich für Zugriff auf CLV41x (Konfiguration/Diagnose)

  • Maximale Leitungslänge zwischen CDB410 und CLV41x beim Einsatz von Verlängerungsleitungen: 10 m (RS-232-Schnittstelle!)
  • Abgenommener Deckel mit Anschlussbild um 180° gedreht in Parkposition arretierbar

¾ Bohrungs- und Gehäusemaße siehe Maßbild (Seite 4), max. Schraubendurchmesser 4 mm.

8010000/TF10/2009-08

Compact connection module for connecting a CLV41x to the host, peripheral equipment, and power supply

  • 9-pin internal D-Sub connector for connecting the host interface 2 (RS 232) to a PC for configuring/troubleshooting the CLV41x
  • Terminals for host interface, switching inputs/outputs, power supply, and shield
  • Externally visible LEDs for indicating active switching inputs and outputs, as well as switch settings for module configuration
  • Enclosure rating IP 65
  • Installation possible with closed cover
  • Maintenance-free
  • UL certificated when a class 2 power supply according to UL 1310 is used

Connection diagrams in CLV-Connect (on the “Manuals & Software Bar Code Scanners“ CD, provided with the scanner or from the Internet www.sick.com)

  • 24 V DC power supply generated in accordance with IEC 742

Free access to internal “AUX” connector is required for access to CLV41x (configuration/troubleshooting)

  • Maximum cable length between CDB410 and CLV41x if extension cables are used: 10 m (32.8 ft) because of RS 232 interface
  • Cover with connection diagram can be removed, rotated through 180°, and locked in park position ¾ See dimensioned drawing for hole and housing dimensions (Page 4), max. screw diameter 4 mm (0.15 in).

© SICK AG · Division Auto Ident · Germany · All rights reserved

1#4

Page 2 of Sick CDB410 Manual

The text of page 2, from the PDF itself

4. Konfigurationselemente und Anzeigen

4. Configuration Elements and Displays

Funktion der Konfigurationsschalter:

Configuration switches
Schalter

FunktionDefaultSwitchFunctionDefaultS 1 (Power)

Anliegende Versorgungsspannung: ON: Versorgungsspannung ein OFF: Versorgungsspannung aus

ON

S 1 (Power)

Connected power supply: ON: Power supply on OFF: Power supply off

ON

S 3 (SGND-GND)

Bezugspotenzial für Sensor-GND: ON: verbunden mit GND d. CLV41x OFF: potenzialfrei

ON

S 3 (SGND-GND)

Reference potential for sensor GND: ON: Connected to GND of CLV41x OFF: Floating

ON

S 5 (410:RS232)

Verschaltung der Hostschnittstelle 2: “HOSTÅ410“: vom CLV41x auf Klemmenleiste “RS232ÆAUX“: vom CLV41x auf Service-Stecker „AUX“

HOSTÅ410

S 5 (410:RS232)

Host interface 2 connection: “HOSTÅ410”: from CLV41x to terminal strip “RS232ÆAUX”: from CLV41x to “AUX” service connector

HOSTÅ410

S 6 (RS485)

RS-422/485-Umschaltung ON: RS-485 OFF: RS-422

OFF

S 6 (RS 485)

RS 422/485 selector ON: RS 485 OFF: RS 422

OFF

S 7 (Term422)

RS-422-Terminierung (Empfänger) ON: Widerstand 120 Ohm zugeschaltet OFF: keine Terminierung

OFF

S 7 (Term422)

RS 422 termination (receiver): ON: 120 Ohm resistor connected OFF: No termination

OFF

Funktion der LEDs:

LEDs
LED

FarbeFunktionLEDColorFunctionPowergrün

leuchtet, wenn die Versorgungsspannung am CDB410 anliegt und Schalter S 1 auf „ON“

Power

green

Lights up when the power supply is connected to the CDB410 and switch S 1 is set to “ON“

Sensor 1, 2

gelb

leuchtet, wenn der entsprechende Eingang des CLV41x schaltet

Sensor 1, 2

yellow

Lights up when the corresponding CLV41x input switches

Result 1, 2

gelb

leuchtet, wenn der entsprechende Ausgang des CLV41x schaltet

Result 1, 2

yellow

Lights up when the corresponding CLV41x output switches

5. Elektrische Installation

5. Electrical Installation

Empfohlene max. Leitungslänge vom CLV41x zum Host:

Recommended max. cable length from CLV41x to host:

SchnittstellentypDatenübertragungsrateEntfernung z. HostInterface typeData transfer rateDistance to hostRS-232

bis 19,2 kBd 38,4 ... 57,6 kBd

max. 10 m max. 3 m

RS 232

Up to 19.2 kBd 38.4 to 57.6 kBd

Max. 10 m (32.8 ft) Max. 3 m (9.84 ft)

RS-422

max. 38,4 kBd max. 57,6 kBd

max. 1.200 m max. 500 m

RS 422

Max. 38.4 kBd Max. 57.6 kBd

Max. 1,200 m (3,936 ft) Max. 500 m (1,640 ft)

Versorgungsspannung DC 24 V (gemäß IEC 60364-4-41):

Power supply 24 V DC (accord. to IEC 60364-4-41):

HINWEIS

NOTICE

Elektrische Trennung! Der Ausgangskreis des kundenseitigen Netzgerätes zur Erzeugung der Versorgungspannung muss gegenüber dem Eingangskreis eine sichere elektrische Trennung durch Doppelisolation und Sicherheitstrafo nach IEC 742 besitzen.

Electrical isolation! The output circuit of the power supply pack provided by the customer must be safely electrically isolated from the input circuit by means of double insulation and a safety isolating transformer according to IEC 742.

Verdrahtung des CDB410:

CDB410 wiring
Elektrische Verbindungen nur im spannungsfreien Zustand herstellen oder lösen. ■ Um den Kurzschluss-/Überlastungschutz der abgehenden Versorgungsleitungen zum CLV410 sicherzustellen, müssen die verwendeten Aderquerschnitte unter Berücksichtigung der im CDB410 eingebauten Sicherung ausgelegt werden. Folgende Normen sind hierbei zu beachten: DIN VDE 0100 (Teil 430), DIN VDE 0298 (Teil 4) bzw. DIN VDE 0891 (Teil 1) ■ Kundenseit. Schirmung am CDB410 auflegen (Klemme „Shield“)

2#4

© SICK AG · Division Auto Ident · Germany · All rights reserved

Connect or release current linkages only under de-energised conditions.

  • To ensure that the outgoing supply cables to the CLV410 are protected against short-circuits/overload, the core crosssections must be dimensioned in accordance with the fuse installed in the CDB410. The valid standards must be observed.
  • Connect the shield of your system to the CDB410 (“Shield“ terminal)

8010000/TF10/2009-08

Page 3 of Sick CDB410 Manual

The text of page 3, from the PDF itself

Klemmenbelegung siehe Anschlussbild auf Seite 4 oder im Deckel innen. Anschlusspläne für Hostschnittstelle/Schalteinund -ausgänge siehe CLV-Connect

  • Um Störeinflüsse zu vermeiden, Leitungen möglichst nicht parallel mit Stromversorgungs- und Motorleitungen verlegen
  • Bezugspotenzial für die Schalteingänge mit Schalter S 3 wählen

For terminal assignment, see connection diagram on Page 4 or inside the cover. For host interface/switching inputs and outputs diagrams, see CLV-Connect

  • To prevent interference, do not lay cables parallel to power supply or motor cables
  • Choose reference potential for switching inputs with switch S 3

¾ Leitung des CLV41x an 15-pol. D-Sub-HD-Buchse anschließen. ¾ Alle anderen Leitungen über Kabel-Verschraubungen spannungsfrei an Klemmen auflegen, für IP 65 nicht verwendete Durchführungen mit Blindstopfen versehen. ¾ Für PC-Zugriff auf Hostschnittstelle 2 des CLV41x (Stecker „AUX“) Schalter S 5 auf Position „RS232ÆAUX“ stellen.

¾ Connect the CLV41x cable to the 15-pin D-Sub HD socket. ¾ Connect all other cables to the terminals (only when the power supply is switched off). Use blanking plugs to close any unused bushings (IP 65). ¾ For PC access to host interface 2 of CLV41x (“AUX” connector) set switch S 5 to position “RS232ÆAUX”.

6. Technische Daten6. Technical DataTyp

CDB410-001 (Nr. 1023813)

Type

CDB410-001 (No. 1023813)

Optische Anzeigen5 x LEDVisual indicators5 x LEDsElektrische Anschlüsse

D-Sub: 15-pol. HD-Buchse/9-pol. Stecker Schraubklemmen, für Adern 0,14 ... 2,5 mm2 Federkraftklemmen, für Adern 0,14...1 mm2

Electrical connections

D-Sub: 15-pin HD socket/9-pin connector Screw terminals, for cores 0.14 to 2.5 mm2 (approx. 26 to 13 AWG) Spring terminals, for cores 0.14 to 1 mm2 (approx. 26 to 17 AWG) 4 x, for cables ∅ 4.5 to 10 mm (0.18 to 0.39 in)

Kabel-Verschraubungen

4 x (für Leitungen ∅ 4,5 ... 10 mm)

Versorgungsspannung1)

DC 6 ... 30 V SELV bzw. PELV nach IEC 60364-4-41 (2005)

Cable glands

Leistungsaufnahme

bei angeschlossenem CLV41x: max. 3 W

Power supply

Sicherung

Glasrohrsicherung 0,8 A träge

6 to 30 V DC SELV respectively PELV to IEC 60364-4-41 (2005)

GehäusePolycarbonatPower consumptionFarbe

blau, Deckel transparent

With connected CLV41x: max. 3 W (125 mA at 24 V DC)

PrüfzeichenCE, UL1)Fuse

Glass tube fuse 0.8 A, type T

Elektrische Sicherheit

nach EN 61010-1 (2001-03)

HousingPolycarbonateSchutzklasse

III, nach EN 61140 (2002-03)

Colour

Blue, transparent cover

Schutzart

IP 652), nach EN 60529 (1991-10); A1 (2002-02)

ConformityCE, UL1)Electrical safety

According to EN 61010-1 (2001-03)

EMV-Prüfung

nach EN 61000-6-2 (2001-10); EN 55011 (1998-05), A1 (1999-08), A2 (2002-10)

Schwing-/Schockprüfung

nach IEC 60068-2-27 (1993)/ nach IEC 60068-2-6 (1995)

Gewicht

ca. 250 g

Temperatur (Betrieb/Lager) 0 ... +40 °C/ –20 ... +70 °C Rel. Luftfeuchtigkeit

max. 90 %, nicht kondensierend

1) UL-zertifiziert bei Verwendung eines Class 2-Netzgerätes (geprüft nach UL 1310) 2) Bei Verwendung der SICK Scanner-Standardanschlussleitung

(gültig bei entsprechender Gerätekennzeichnung auf dem Typenschild)

1)

Protection class

III, according to EN 61140 (2002-03)

Enclosure rating

IP 652), according to EN 60529 (1991-10); A1 (2002-02)

EMV tested

According to EN 61000-6-2 (2001-10), EN 55011 (1998-05), A1 (1999-08), A2 (2002-10)

Vibration/shock tested To IEC 60068-2-27 (1993)/IEC 60068-2-6 (1995) Weight

Approx. 250 g (approx. 8.75 oz)

Temperature (operation/storage)

0 to +40 °C/ –20 to +70 °C (+32 to +104 °F/ –4 to +158 °F)

Rel. air humidity

Max. 90 %, non-condensing

1) UL certificated when a Class 2 power supply according to UL 1310 is used 2) With SICK standard scanner cable

(valid only with corresponding product marking on the nameplate)

7. Accessories7. Zubehör Bestell-Nr.BeschreibungOrder no.Description6010075

Verlängerungsleitung für CLV41x, 2 m, geschirmt, mit 15-pol. D-Sub-HD-Stecker/Buchse

6010075

Extension cable for CLV41x, 2 m (6.56 ft), shielded, with 15-pin D-Sub HD connector/socket

4038847

IP 65-Dichtung zur Anwendung zwischen Scanneranschlussleitung und Verlängerungsleitung

4038847

IP 65 gasket for use between scanner connection cable and extension cable

2014054

RS-232-Datenleitung (Nullmodemleitung), 3 m, geschirmt, mit 2 x 9-pol. D-Sub-Buchse, zum Anschluss an den 9-pol. D-Sub-Stecker „AUX“ im Inneren des CDB410

2014054

RS 232 data cable (null modem cable), 3 m (9.84 ft), shielded, with 2 x 9-pin D-Sub socket for connecting to the 9-pin D Sub plug “AUX“ inside of the CDB410

6005695

Datenleitung, Meterware, twisted pair, geschirmt, für RS-232 und RS-422/485-Schnittstellen

6005695

Data cable, bought to size, twisted pair, shielded, for RS 232 and RS 422/485 interfaces

8010000/TF10/2009-08

© SICK AG · Division Auto Ident · Germany · All rights reserved

3#4

Page 4 of Sick CDB410 Manual

The text of page 4, from the PDF itself

8. TroubleshoootingStörungAbhilfeMalfunctionRemedy

  • Versorgungsspg. angeschlossen, aber LED „Power“ leuchtet nicht
  • Schalter S 1 (Power) in Position „ON“ bringen
  • “Power” LED does not light up when power supply is connected
  • Set switch S 1 (Power) to “ON”
  • Datenübertragung auf der Hostschnittstelle funktioniert nicht
  • Host gemäß CLV-Connect anschließen
  • Schalter S 5 in Position „HOSTÅ410“ bringen
  • Data transfer malfunction on host • Connect host in accordance with interface CLV-Connect
  • Set switch S 5 to “HOSTÅ410”
  • Signale des angeschlossenen Lesetaktsensors bleiben wirkungslos
  • Sensor gemäß CLV-Connect anschließen
  • Stellung des Schalters S 3 (SGND–GND) prüfen
  • Mit Hilfe von „CLV-Setup“ die Quelle des Lesetaktes im CLV41x auf „Sensor 1“ einstellen. Download zum CLV41x!
  • Signals from connected reading clock sensor have no effect
  • Connect sensor in accordance with CLV-Connect
  • Check the S 3 switch (SGND–GND)
  • Using “CLV-Setup”, set the reading clock source on the CLV 41x to “Sensor 1”. Download to the CLV41x
  • Nach Anschluss des PCs an den Stecker „AUX“ kein Zugriff auf den CLV41x mit CLV-Setup
  • Schalter S 5 für Zugriff temporär in Position „RS232ÆAUX“ bringen
  • Mit Hilfe der Funktion „AutoBaudDetect“ in „CLV-Setup“ die Kommunikationsparameter des PC automatisch wählen
  • Cannot access CLV41x with CLVSetup after connecting the PC to the “AUX” connector
  • Set switch S 5 temporarily to “RS232ÆAUX” for access
  • Using the “AutoBaudDetect” function in “CLV-Setup”, configure the PC communication parameters automatically

Alle Angaben in mm (inch)/All dimensions in mm (inch)

Anschluss CLV41x CLV41x connection

Maßbild/dimensioned drawing

Klemmenleisten Terminal strips

Konfigurationsschalter Configuration switches

Anschluss PC PC connection

Aufbau, Klemmenbelegung/design, terminal assignment

LEDs

8010000/TF10/2009-08 · 5M/TR <PM 6.5> · KE · Printed in Germany · Subject to change without prior notice · The specified product features and technical data do not represent any guarantee · AftE6305sw

8. Fehlersuche

SICK AG · Waldkirch · Germany · www.sick.com

4#4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8010000/TF10/2009-08