User's guide for the Renaissance Learning AccelScan Model 1100 intelligent mark recognition scanner, used to read scan cards. It explains connecting power and USB, installing the drivers on Windows and Macintosh OS 9 computers, starting to scan, and cleaning the scanner.

Device type
Intelligent mark recognition scanner for scan cards p. 2
Interface
USB data cable, already attached to the scanner p. 2
Power
External power supply box with a power cord; plugs into the scanner with a small round connector p. 2
In the box
AccelScan Model 1100 with USB cable attached, power cords, AS Drivers CD p. 2
Computers supported
Windows 2000, XP and Vista; Windows 98; Macintosh OS 9 p. 2, 3
Driver folders
Win2k-XP-VISTA, Windows98-ME and OS9 folders on the AS Drivers CD p. 2, 3
Mac OS 9 driver file
USBSerialConverter_04036001, copied into the Extensions folder p. 3
Guide revision
Revised 07-07 p. 2

What this manual walks you through

  • Connecting the scanner and installing drivers on Windows 2000, XP and Vista p. 2
  • Installing the driver on Windows 98 with the Add New Hardware Wizard p. 3
  • Installing the driver on a Macintosh with OS 9 p. 3
  • Starting to scan with your scanning software p. 3
  • Cleaning the scanner p. 3

Good to know

  • On Windows 2000, XP and Vista, click Cancel when the Found New Hardware Wizard appears, then install from the CD. p. 2
  • Insert scan cards face down. p. 3
  • Do not use correction fluid on cards; it can stick to the scanner lens. p. 3
  • Do not staple, clip, bend or fold scan cards. p. 3
  • The manual states the scanner complies with Part 15 of the FCC rules and is a Class B device under Canadian ICES-003. p. 4

Questions this manual answers

Where do I get drivers for the AccelScan 1100?

They are on the AS Drivers CD that comes with the scanner, in a folder for each type of computer. p. 2

Does the AccelScan 1100 work with Windows Vista or a Mac?

The guide gives driver steps for Windows 2000, XP and Vista, Windows 98, and Macintosh OS 9. p. 2, 3

My scanning software cannot find the AccelScan. What do I do?

See the manual for your scanning software to select the scanner's port and/or model. p. 3

How do I clean an AccelScan scanner?

Unplug it, open the top, wipe it with a soft damp cloth without sprays or solvents, and close the top until it snaps. p. 3

Which way do scan cards go into the AccelScan?

Face down. p. 3

The file

Size and text

Pages4
PDF151 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Renaissance Learning AccelScan 1100 Manual

The text of page 1, from the PDF itself

1100 User’s Guide Tested to comply with FCC standards for home or office use

R3969281

Page 2 of Renaissance Learning AccelScan 1100 Manual

The text of page 2, from the PDF itself

Renaissance Distribution Centers: In the US: Renaissance Distribution Center 2810 Industrial Street Wisconsin Rapids, WI 54495 Toll-free number: (866) 492-6284 In the UK: Renaissance Distribution Center 32 Harbour Exchange Square London E14 9JX Telephone: +44(0)20 7184 4000 Fax: +44(0)20 8804 04540

Thank you for purchasing the AccelScan intelligent mark recognition scanner. AccelScan will help you improve your workflow with its accurate, high-speed scanning. AccelScan is easy to set up so that you can use it with all your scanning software.

Before You Begin Before you install AccelScan, make sure you received the following items:

  • AccelScan Model 1100 with USB cable attached
  • Power Cords

© 2007, Renaissance Learning, Inc. This publication is protected by US and international copyright laws. It is unlawful to duplicate or reproduce any copyrighted material without authorization from the copyright holder. This document may be reproduced only by staff members in schools that own AccelScan scanners. For more information, contact Renaissance Learning, Inc. at the address above. Renaissance, Renaissance Learning, and AccelScan are trademarks of Renaissance Learning, Inc., registered or pending registration in the United States and in other countries. Macintosh is a registered trademark of Apple Computer, Inc., registered in the US and other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.

  • AS Drivers CD

Connecting the AccelScan and Installing the Drivers Follow the steps for your type of computer.

Windows Comput er s Windows 2000, XP, and Vista 1. You received a power cord and a power supply box with a cable attached. Connect the power cord to the power supply box. Then, plug the small round connector into the AccelScan, and plug the power cord into an outlet. 2. The USB data cable is already connected to the AccelScan. Connect the other end of this cable to a USB port on your computer. 3. When the Found New Hardware Wizard appears, click Cancel. 4. Insert the AS Drivers CD that you received with the AccelScan into your computer and view the CD’s contents. Open the Win2k-XP-VISTA folder. 5. Double-click the Install.exe file. 6. Click Next > in the Welcome panel of the Device Driver Installation Wizard.

Revised 07-07

2

7. Click Finish when the Wizard tells you the drivers were successfully installed. (If the Found New Hardware Wizard also appears to tell you the drivers were installed, click Finish there as well.) You may be asked to restart your computer. You can now use the scanner with your programs. 3

Page 3 of Renaissance Learning AccelScan 1100 Manual

The text of page 3, from the PDF itself

Windows 98 1. You received a power cord and a power supply box with a cable attached. Connect the power cord to the power supply box. Then, plug the small, round connector into the AccelScan, and plug the power cord into an outlet. 2. The USB data cable is already connected to the AccelScan. Connect the other end of this cable to a USB port on your computer. A message will notify you that the computer is building a driver database. After this disappears, the Add New Hardware Wizard will appear. 3. Click Next > in the first panel of the Wizard. 4. In the next panel, leave Search for the best driver for your device selected and click Next >. 5. Insert the AS Drivers CD that came with the AccelScan into your computer. 6. In the Wizard, check the box for specifying a location. Then, click Browse. 7. Open the Windows98-ME folder on your CD and click OK. When you return to the Wizard, click Next >. 8. The Wizard will show you the driver has been found. Click Next >. 9. Click Finish when the driver installation is complete. A New Hardware Found message will appear briefly and disappear after a short time. You can now use the scanner with your programs.

Maci nt osh Computers OS 9 1. Insert the AS Drivers CD that came with your AccelScan into your computer. 2. On the CD, open the OS9 folder and find the USBSerialConverter_04036001 file. Copy this file. 3. Open the System Folder on your computer; then, open the Extensions folder. Paste the file into that folder. 4. Restart your computer. 5. You received a power cord and a power supply box with a cable attached. Connect the power cord to the power supply box. Then, plug the small round connector into the AccelScan, and plug the power cord into an outlet. 6. The USB data cable is already connected to the AccelScan. Connect the other end of this cable to a USB port on your computer. You can now use the scanner with your programs. 4

How to Start Using the AccelScan 1. Restart the computer. 2. Start your scanning software.The software will automatically search for the scanner connection. If the scanning software cannot detect the AccelScan, see the manual that came with your software to select the scanner’s port and/or model. 3. Once the software recognizes the scanner, you are ready to scan. Be sure to insert cards face down when you scan them.

Maintaining the AccelScan How to Clean the AccelScan To clean the AccelScan, follow these steps: 1. Unplug the AccelScan from the electrical outlet. 2. Open the top of the scanner as shown. 3. Wipe the AccelScan with a soft, damp cloth. Do not spray the unit or use solvents. 4. Close the top of the scanner until it snaps into place.

How to Avoid AccelScan Problems

  • Do not use correction fluid, which can adhere to the AccelScan lens.
  • Do not staple scan cards. Remove paper clips from the cards before scanning. Do not bend or fold the scan cards.
  • Ask students to keep the scan cards clean.

5

Page 4 of Renaissance Learning AccelScan 1100 Manual

The text of page 4, from the PDF itself

Problems?

Notices

If your AccelScan fails to perform as designed, please call the nearest Renaissance Distribution Center. (See the front cover of this User Guide.) If we cannot solve the problem over the phone and your AccelScan is under warranty, we may ship a replacement and give you instructions for returning the original scanner. If you return the original scanner, please do not write on it. If you need to include notes, write them on a separate sheet of paper and return it with the scanner. Renaissance Learning will arrange for the faulty scanner to be picked up. If you do not return your faulty AccelScan within 15 days, you will be billed the full price for the replacement AccelScan.

This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B device complies with Canadian ICES-003. Cet appareil numérique de la classe B respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada.

Warranty Renaissance Learning, Inc. (RLI) warrants each AccelScan intelligent mark recognition scanner sold by RLI to be free from defect in material and workmanship under normal use and service beginning with the date of delivery to the purchaser. This warranty is subject to the following conditions: The warranty period is classified as one (1) year and is limited to the replacement or repair during the warranty period and subject to conditions enumerated below, of such product returned intact which shall appear to RLI, upon inspection, to have been defective in material or workmanship. Replacement or repair will be accomplished at one of the Renaissance Distribution Centers. (See the front cover of this User Guide.) Such replacement shall be made free of charge if a defect becomes apparent and RLI is notified within the warranty period. This warranty does not include any taxes which may be due in connection with replacement or repair, nor any installation, transportation, or postage costs to return the unit to RLI. This warranty does not cover repair or replacement because of damage from unreasonable use (damage from road hazards, accident, fire or other casualty, misuse, negligence, incorrect wiring, lightning, etc.) and any use or installation not in conformance with instructions furnished by RLI or repairs or replacement needed because of modifications not authorized or supplied by RLI. This warranty is expressly in lieu of any other warranties, express or implied, including any warranty of merchantability or fitness for particular purpose. Remedies under this warranty are expressly limited to the provision of products as specified above and any claims for loss arising out of the failure of products to perform for any period of time, or special, indirect, or consequential damages or other economic loss are expressly excluded. 6