Page 15

The existing Base Station system configuration can be automatically downloaded to the scanner. This automatic download feature is configurable and can be disabled. See the section, Common Configuration for more information about this feature. If downloading occurs, a slight delay with link verification announcement will occur.

CAUTION

Verifying Scanner-to-Base Station Communications

Since a new/replacement scanner may have been shipped with a custom configuration or may have been modified with other special programming, it may not be desirable to download a potentially older configuration from an existing Base Station. In this case, reference the RF Programmable Features section of this manual, or the Configurator Express™ On Screen Programming Software and consider uploading the scanner’s newer configuration to the Base Station prior to linking.

Point the linked scanner at a sample bar code from Appendix A, and pull the trigger (see How to Scan for tips on scanning bar codes). Watch the TX/RX (transmit/receive) indicator LED on the Base Station and/ or scanner green LED while scanning the bar code. The LEDs should flash momentarily as the two devices communicate. If no communication is indicated, see the section titled, If the Scanner Fails to Link with the Base Station. When the scanner is programmed to do so, communication can also be indicated by a second "acknowledgement" tone 1 that is sounded after a "good read" tone. If a transmission error beep (warble) is heard following a "good read" tone instead of the single acknowledgement tone, communication between the devices may have failed2. Refer to the sections Using the PowerScan RF System, and Maintenance and Troubleshooting for possible remedies, should this occur.

Using the PowerScan RF System This section covers the following topics: •

Battery Charging and Maintenance

•

How to Scan

1. See LED and Beeper Indications for more details about beeper signals. 2. Other reasons for a "warble" are that the Base Station may be configured differently than the scanner, or that the system’s interface doesn’t support the symbology (bar code type) you’re trying to scan.

Systems Manual

11

Page 16

•

LED and Beeper Indications

•

Maximizing Signal Range

•

Three-Position Lock

Battery Charging and Maintenance

NOTE

When the scanner is in use, a low battery condition is indicated by a repeated two-flash signal from the scanner’s green LED every time the trigger is pulled before the laser is enabled. This indicator may have been disabled via custom programming. See LED and Beeper Indications for more information.

Seat the scanner in the Base Station as shown in Figure 6, ensuring that the battery fully engages the station’s metal contacts. The CHARGE LED on the Base Station should flash, indicating the battery is charging.

Figure 6. Charging the Battery

Rapid flashing indicates that charging is taking place. Rapid charging occurs when the battery temperature is between 10°C (50°F) and 46°C (115°F), and/or voltage of the battery is between 2.0 and 3.2V. Charge time is less than 4.2 hours. Rapid charge ends with the battery at approximately 90 to 95% capacity. The CHARGE LED remains on steady when trickle charging or after the charge cycle is complete.

A scanner may be charged simultaneously while other scanners are in use with the Base Station. NOTE

12

PowerScan™ RF Scanner

Page 17

NOTE

Batteries will not charge if their temperature is below 0°C (30°F). If a battery that is too cold is inserted into the Base Station, the Charge LED will not illuminate.

Tips for Nickel Metal Hydride (NiMH) batteries will better hold a charge if Extending allowed to discharge at least once a week. The chemical reactions that Battery Life correspond to charge and discharge in a rechargeable battery should occur to obtain the maximum number of charge/discharge cycles in the battery. If a battery is removed from the scanner and stored, it should be fully charged when stored. Batteries will lose the ability to hold a charge when stored for long periods of time (weeks, months, or longer). Batteries will typically have about 30% charge capacity when shipped. To assure maximum usage, the battery should be fully charged before use. Store your battery in a cool dry place. Do not leave your battery exposed to direct sunlight or temperatures below 0°C (30°F) and above 38°C (100°F).

Disposing of There presently are no US, North America or World disposal requireBatteries ments for NiMH batteries, so when they won't hold a charge anymore, the batteries can be disposed of, preferably through a recycling center.

Four Station If you have a Four Station Charger, batteries are inserted for charging Charger as shown in Figure 7. A 90% rapid charge can be achieved in only two hours when using this optional accessory; half the time than when a Base Station is used for charging. The LEDs at each battery station operate the same as the CHARGE LED on the Base Station, with rapid flashing indicating that rapid charging is taking place and on steady during trickle charging or when the rapid charge cycle is finished.

NOTE

Systems Manual

If you insert a battery into the Four Station Charger and no LEDs illuminate, the battery may be too cold. Batteries must be at 0°C or higher to charge. Do not attempt to charge cold batteries, since placing them in the charger will curtail the charging of other batteries already present in the unit.

13

Page 18

Figure 7. Using the Four Station Charger Accessory

1

2

1.

14

Device Power LED

2.

Station Charge LEDs

PowerScan™ RF Scanner

Page 19

How to Scan Figure 8 illustrates some tips to help get the best scanning results: 1.

The scanner must be pointed at a slight angle to the bar code. Do not hold the scanner perpendicular to the bar code.

2.

The laser beam must cross the entire bar code. The scanner cannot correctly read if the entire bar code is not scanned.

Figure 8. Scanning Tips

1

1

2 2

Systems Manual

15

Page 20

Depth of Field There are currently four different range models for the RF scanner. Depending upon the model type of your scanner, you’ll need to hold the unit at a given distance from the bar code to achieve optimum scanning results. The following diagrams provide depth of field information for each of the models when scanning grade A, Code 39 bar codes: Standard Range (SR), High Density (HD), Long Range (LR) and Extra Long Range (XLR). Definition of a "mil"

A "mil" is equal to 0.001 inches. In the context of the illustrations in this section, a mil represents the minimum bar code element width. Thus a 5 mil bar code would have a minimum element width of 5 mils (or 0.005 inches). Measurements are based on SR models set with the standard 28° scan width (as opposed to the Half Angle setting of 14°). Reference the Programming Manual for more information about the Half Angle feature.

NOTE

Specifications are subject to change without notice.

Figure 9. Depth of Field (SR)

Depth of Field Paper Labels (SR decoded model, Code 39)

FRONT OF SCANNER

5 mil

7.5 mil 10 mil 15 mil 20 mil 40 mil 55 mil 1

0

16

10

20

30

2

40

50

60

3 FEET 70

80 90 100 CENTIMETERS

4

110

120

5

130

140

150

160

170

PowerScan™ RF Scanner

Page 21

See the section titled, Definition of a "mil" for more information about reading this chart. Measurements are based on HD models set with the standard 28° scan width (as opposed to the Half Angle setting of 14°). Reference the Programming Manual for more information about the Half Angle feature.

NOTE

Specifications are subject to change without notice.

Figure 10. Depth of Field (HD) Depth of Field FRONT OF SCANNER

Paper Labels (HD decoded model, Code 39)

3 mil

4 mil 5 mil 7.5 mil 10 mil 20 mil

1

0

Systems Manual

2

5

3

INCHES

4

10 CENTIMETERS

5

6

15

7

8

20

17

Page 22

See the section titled, Definition of a "mil" for more information about reading this chart. Measurements are based on LR models set with the a 14° scan width (as opposed to the alternate Full Angle setting of 28°). Reference the Programming Manual for more information about the Half Angle feature.

NOTE

Specifications are subject to change without notice.

Figure 11. Depth of Field (LR) Depth of Field

FRONT OF SCANNER

Paper Labels (LR decoded model, Code 39)

7.5 mil

10 mil 15 mil 20 mil 40 mil 55 mil

1

0

10

20

30

2

40 50

3

60 70

4

5 FEET

6

7

8

9

80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 CENTIMETERS

FRONT OF SCANNER

Reflective Labels (LR decoded model, Code 39)

40 mil 55 mil 70 mil 100 mil

1

2

3

4

5

6

7

8

9

10

11

12 13 FEET

14

15

16

17

18

19

20

21

22

0 10 30 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 370 390 410 430 450 470 490 510 530 550 570 590 610 630 650 670 CENTIMETERS

18