Page 5
Introduction About This This systems manual provides information and instructions to connect Manual and configure your PowerScan™ RF system. The following sections are included in the manual: •
Introduction presents general information about the contents of this manual and about the system.
•
Quick Start Instructions provide easy to follow procedures for installing your system quickly.
•
Using the PowerScan RF System provides details about scanning basics, system controls and indicators.
•
Mounting the Base Station demonstrates ways to securely attach the Base Station to various work surfaces.
•
RF Programmable Features is a set of procedures detailing system configuration that is unique to the RF system.
•
Maintenance and Troubleshooting provides solutions for problems that may be encountered during installation and use of the system.
•
Standard Warranty is a statement describing the warranty policy covering the system.
References Other manuals are available for this product. Printed copies can be ordered through your distributor. Some manuals can be downloaded at our website address listed on the back cover of this manual. Read the terms of use and instructions at the site to download, save, view or print the most current manual(s) from the internet. Configurator Express™ On-Screen Programming offers a convenient way to program your scanner using your PC. Information about ordering a kit (includes software, adapter and cable) for your RF scanner can also be accessed from our website (see the back cover of this manual).
Systems Manual
1
Page 6
Product The PowerScan™ RF scanner is designed for durability, with high Description impact-resistant material and protective rubber cushioning at every point of impact, and it also provides the unleashed freedom of Radio Frequency (RF) communication with your host system. Scanner and Base Station nomenclature and labeling are shown in Figure 1 and Figure 2 below.
Figure 1. Scanner Labels and Nomenclature 2 RF
1
COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:
4,387,297 • 4,409,470 • 4,460,120 4,593,186 • 4,652,750 • 4,673,805 4,736,095 • 4,816,660 • 4,845,350 4,861,972 • 4,866,257 • 4,879,456 5,179,270 • 5,180,904 • 5,237,161 5,247,161 • 5,247,162 • 5,258,604 5,260,554 • 5,298,728 • 5,311,000 5,330,370 • 5,468,949 • 5,475,206 5,481,098 Other patents pending
4 3
5
CAUTION - LASER RADIATION WHEN OPEN. AVOID EXPOSURE TO BEAM.
6
1.
Trigger
4.
Tether Hook
2.
Scan Window
5.
Yellow LED
3.
Green LED
6.
Battery
NOTE
2
Figure 1 and Figure 2 show label placement ONLY. For actual regulatory, patent and other applicable information, view the labels on the product itself, or call your nearest sales or service representative.
PowerScan™ RF Scanner
Page 7
Figure 2. Base Station Labels and Nomenclature
2
3
5
4 1
6 E ID
PSC INC. 959 Terry Street Eugene, OR 97402 U.S.A. ACN N263
C
BAS X TX/R GE R CHA WER PO
US
LISTED NWGQ 2Z78
14
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference, including interference that may cause undesired operation.
7
Applicable patents are listed on label inside handheld unit.
8 FCC ID: O9NPWRSCAN-BS CANADA38621032367A
13
9
MODEL: PowerScan RF Base Station CLASS No. SERIAL No. FREQ:
Use ONLY PSC AC/DC Power Supply Input: +7.5V to +14V Power: 5.5 Watts (max)
10 b 12 a
11
1.
Antenna
8.
Interface (I/F) Connector
2.
Transmit/Receive (TX/RX)/ Diagnostics LED
9.
Cable Retainer
3.
Charge LED
10
Power Connector
4.
Power LED
11.
Power Supply - (a) AC Adapter or (b) Forklift DC Converter
5.
Base ID Bar Code
12.
Interface (I/F) Cable
6.
Charging Pins
13.
Mounting Key Slots (3)
7.
3-Position Lock
14.
Mounting Flanges (4)
Systems Manual
3
Page 8
Laser Cautions The PowerScan RF bar code scanner is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J for Class II laser products (SR and LR) and Class IIIa (XLR). Class II and IIIa products are not considered to be hazardous. The scanner contains a Visible Laser Diode (VLD) at a wavelength of 650-670 nanometers and is designed so that there can be no human access to harmful levels of laser light during normal operation, user maintenance, or during prescribed service operations.
CAUTION
CAUTION
In the unlikely event that a bright laser spot is experienced rather than a scan line, do not stare into the beam or attempt to repair the unit. Discontinue operation and return the unit to your dealer. Note that when using Marker Beam Mode, a single aiming dot is projected momentarily preceding a scan line and is not considered a malfunction. Do not open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item.
The PowerScan™ RF scanner is required to be used in conjunction with the PSC Base Station, Model: PowerScan RF Base Station. NOTE
4
PowerScan™ RF Scanner
Page 9
Radio Frequency Interference This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.
This device may not cause harmful interference, and
2.
This device must accept any interference received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB003 du Canada. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be dertermined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Systems Manual
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
5