Page 43
Chapter 2: Getting Started Power Properties
System Status Power Icon
Description
Low Backup (inter- Appears when backup battery voltage is less than 2.500 V. nal) Battery Docked Indicator (netpad connected to power)
Appears when netpad is in powered docking station and main battery is fully charged. Disappears when netpad is removed from docking station.
Low Main Battery
Appears when main battery voltage is between 5% and 15% of configured shutdown threshold.
Critical Main Battery
Appears when main battery voltage is within 5% of configured shutdown threshold.
Charging Main Battery
Appears when the netpad is connected to a powered docking station and the battery is charging. All charge-related icons disappear if battery levels are not low or critical, and the netpad is not connected to an external power source.
No Charge Icon
Table 2.8 Power Icons’ Charge States
2.3.2.1
Main Battery
To check the battery power status, click on the Main Battery tab. This screen describes the main battery, and its state.
Figure 2.9 Power Properties: Main Battery Psion Teklogix netpad Windows CE .NET 4.2 User Manual
17
Page 44
Chapter 2: Getting Started Power Properties
2.3.2.2
Internal Battery
The internal battery provides temporary backup of data on the terminal while the main battery is being replaced. To check the internal battery power status, click on the Internal Battery tab. This screen describes the state of the internal battery, its voltage, and its type.
Figure 2.10 Power Properties: Internal Battery
2.3.2.3
Power Saving Schemes
The Schemes tab accesses the power states: Dim, Stand-By and Suspend. These states can be enabled after an elapsed time range, that can be set depending on whether the netpad is on battery power or external power.
Figure 2.11 Power Properties: Schemes 18
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 45
Chapter 2: Getting Started Power Properties
Note:
The Power Properties Schemes settings are cumulative - that is, to determine when the netpad enters ‘Suspend’ state, the unit waits for the ‘Dim’ state to elapse, followed by the ‘Stand-By’ state and then, once the ‘Suspend’ state time has elapsed, ‘Suspend’ state is activated.
When setting the Dim, Stand-By, and Suspend states, keep the following in mind. Because the netpad ‘wakes up’ from the Dim and Stand-By states almost instantaneously following any user input (button press, screen tap), the timeouts you set will not slow user activity. The sum of the Dim, Stand-By, and Suspend timeouts should be selected carefully since the netpad will go to sleep (appear off) when this time has elapsed, saving battery power. The length of the timeouts should be kept to a minimum to help conserve battery life. The least amount of power is consumed during the Suspend state. Setting any of these timeouts to Never does not affect the other timeout options, but will adversely affect the battery run time. If all three timeouts are set to Never, the netpad will remain on. To further reduce power consumption, carefully consider the duration of time that the display backlight is ON or turned up (see “Backlight Properties” on page 30). The following are the default values for the power schemes options: Option
AC Power
Battery Power
Switch to Dim
After 1 Minute
After 10 seconds
Switch to Stand-By
Never
After 1 minute
Switch to Suspend
Never
After 30 minutes
Enable screen tap disabled disabled
Table 2.12 Power Schemes Default Values
Power Scheme This dropdown menu allows you to specify settings for Inactivity Timer based on last, Switch to Dim, Switch to Stand-By, and Switch to Suspend, based on whether the unit is running on AC Power or Battery Power. You can specify one set of values when the unit is running on AC power, and another set when the unit is running on battery power.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
19
Page 46
Chapter 2: Getting Started Power Properties
Inactivity Timer Based On Last This parameter allows you to choose what type of event is monitored by Power Management. If you select User Event, the Inactivity Timer for switching into Stand-By or Suspend is started from the last time you press a Navigation button, a function key, or use the touchscreen. “System Events” include activity on the serial port, an active radio session, IrDA activity, or an active application. If you select User/System Event, then the Inactivity Timer starts from the last time a User Event occurred or the last time System activity occurred. For example, in this mode an active radio would prevent the netpad from going into Stand-By or Suspend until after that radio session has ended. This parameter has no impact on the Switch to Dim Inactivity Timer.
Figure 2.13 Power Schemes: Inactivity Timer based on last
Switch To Dim During Dim state (see Figure 2.14 on page 21), the backlight brightness is turned down after the specified time has elapsed if the netpad does not receive any user input, including activities such as a screen tap, a scan, and so on - any user-initiated activity. When the netpad enters the Dim state, it begins to monitor the time specified in the Switch to Stand-By menu. Press any navigation button or tap the screen the bring the netpad out of Dim state.
20
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 47
Chapter 2: Getting Started Power Properties
Figure 2.14 Power Schemes: Dim
Switch To Stand-By In Stand-By state (see Figure 2.15), the netpad turns off the display, but the programs and netpad hardware remain active. Stand-By is activated when the time specified in the Switch to Dim and the Switch to Stand-By options have elapsed without any activity. The netpad then begins to monitor the Suspend time. Press the power button to put the netpad into Stand-By state. Press the button again to wake up the unit.
Figure 2.15 Power Schemes: Stand-By
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
21
Page 48
Chapter 2: Getting Started Power Properties
Switch to Suspend Once the time specified in the Dim and the Stand-By states have elapsed, the netpad begins to count down the time specified in the Switch to Suspend option. When the time in the Suspend option elapses, the unit enters Suspend state. In Suspend state, the netpad CPU suspends all activity, turns off the display, and goes into a low power state. The state of the device (RAM contents) is preserved. Select Suspend from the Start Menu or hold down the power button for 4 seconds to put the netpad into Suspend state. Press the power button to wake up the unit. You can also enable a screen tap to wake the unit from Suspend by checking that option box below the Switch to Suspend menu. Note:
When the netpad is in suspend state, any network connection is broken. To resume, you must re-establish the network connection.
Figure 2.16 Power Schemes: Suspend
22
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 49
Chapter 2: Getting Started Power Properties
2.3.2.4
Battery Settings
This screen allows you to check the current status of the battery and to configure the battery settings so that the netpad will warn you when the main battery charge is low.
Figure 2.17 Power Properties: Battery Settings To set the Battery Suspend Threshold, click on the Battery Settings tab. The available settings are set on a sliding scale, and range from 20 to 70%. The Battery Suspend Threshold value confirms the setting made on the sliding scale. A warning message to change or recharge the battery will appear when the main or backup battery levels become critically low. The Estimated Operating Time and Estimated Main Battery Backup Time values are calculated based on current use and the remaining battery charge. These figures will change, depending on user activity level and type.
2.3.2.5
Device Status
The Device Status tab lists the devices controlled by the power manager, and their respective power levels (see Figure 2.18 on page 24). The available power levels are D0 (active), D1 (Dim), D2 (Stand-By), D3 and D4 (Suspend), and Power loss (no power). The device names are represented as follows: \Windows\sa_lcd2.dll Display driver. NDS0
NDIS driver.
PWR1
Power button, which passively supports power management to control the system power states.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
23
Page 50
Chapter 2: Getting Started Flight Mode Settings
Figure 2.18 Power Properties: Device Status
2.3.3 Flight Mode Settings Flight Mode turns off the PCMCIA card in your netpad. This mode serves two purposes. On a radio-equipped netpad, using Flight Mode disables radio communications so that you may use your netpad during an airline flight. On a PCMCIA-equipped netpad, using Flight Mode conserves power when you do not need the features of the card. To turn Flight Mode ON, open the Flight Mode icon in the Control Panel. When enabled, an airplane icon will appear in the taskbar. Note:
Remember to turn Flight Mode OFF when the radio or PCMCIA card is needed. To open Flight Mode Settings in order to disable it, click on the airplane icon in the taskbar.
Figure 2.19 Flight Mode Settings 24
Psion Teklogix netpad Windows CE .NET 4.2 User Manual