The text of a manual · part 18 of 26
netpad Windows CE .NET 4.2 User Manual: Configuring Communications 7, pages 153 to 162
Pages 153 to 162 of 230, from netpad Windows CE .NET 4.2 User Manual
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Teklogix NetPad 5510, Teklogix NetPad 5520, Psion NetPad 5510 and Psion NetPad 5520
Page 153
Chapter 7: Configuring Communications GSM/GPRS Radio Configuration 13. The “Registering to Network” message should appear. If registration is successful, the message “Setting APN” will be displayed briefly. If registration fails, the “Could not register with” message will appear.
14. Next, open the Control Panel. Double-click on the Network and DialUp Connections icon. The following menu will appear.
15. Double-click on the Make New Connection wizard. Type the connection name “GPRS” into the text box, and verify that the Dial-Up Connection radio button is selected. Click on the Next button.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
127
Page 154
Chapter 7: Configuring Communications GSM/GPRS Radio Configuration 16. Select Globetrotter from the dropdown list in the Modem screen.
17. Click on the Configure button next to the dropdown list, and the following menu appears. From the Baud Rate dropdown list, select 115200.
18. Then click on the Call Options tab to access the following menu.
19. Uncheck the Wait for dialtone before dialing box and click OK. The Modem selection screen will return. Click on the Next button.
128
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 155
Chapter 7: Configuring Communications GSM/GPRS Radio Configuration 20. The following menu appears. Enter the phone number. Most providers use *99# as the GSM/GPRS phone number.
21. Click on the Finish button. It will return to the Network and Dial-Up Connections screen. You should now see a connection called “GPRS”. 22. Double-click on the GPRS connection. This will bring up the Dial-Up Connection screen. Click on the Dial Properties... button.
23. This will bring up the Dialing Properties dialogue box. From the When dialing from: dropdown list, select GSM/GPRS. Click OK.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
129
Page 156
Chapter 7: Configuring Communications Bluetooth Radio Configuration 24. You should be returned to the Dial-Up Connection screen.
25. Enter your User Name and Password, if your provider has given you one. Note:
Not all providers require a user name or password.
26. To start a GPRS session, click on the Connect button. Important:
While GSM/GPRS is active, ActiveSync will not be available.
7.4 Bluetooth Radio Configuration Bluetooth is a global standard for wireless connectivity for digital devices. The technology is based on a short-range radio link that operates in the ISM band at 2.4 GHz. When two Bluetooth-equipped devices come within 10 meters’ range of each other, they can establish a connection. Because Bluetooth utilizes a radio-based link, it doesn't require a line-of-sight connection in order to communicate. Note:
The Bluetooth radio card uses an internal antenna.
The following menus provide the configuration settings for the Bluetooth radio card. For details on setting up a modem through the serial port, please refer to “Connecting The Modem” on page 153. Important:
130
Other Bluetooth devices that connect with the netpad may use different terminology for some features (i.e. Authentication, Pairing, Bonding, etc.). Verify that the features being configured are the same on each device.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 157
Chapter 7: Configuring Communications netpad Bluetooth Settings
7.4.1 netpad Bluetooth Settings Open the Control Panel and double-click on the Bluetooth Device Properties icon.
The Bluetooth manager will open showing the Bluetooth Controls dialogue box.
There are three menu pages: Devices, Servers and Property. The Devices menu is for scanning and activating remote Bluetooth devices and their services (or ‘profiles’). See Section 7.4.1.1 on page 132 for details. The Servers menu is used for configuring the Bluetooth servers offered by your netpad (Section 7.4.1.2 on page 135). The Property menu shows information about your netpad and allows you to set some options (Section 7.4.1.3 on page 136). Note:
Ensure that the intended device (another netpad, a Zebra® printer, etc.) is powered on, and that its Bluetooth radio is enabled (this is automatic for Zebra printers and the netpad).
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
131
Page 158
Chapter 7: Configuring Communications netpad Bluetooth Settings
7.4.1.1
Devices Menu Page
Scan In the Devices menu page, click on the Scan button and wait for the netpad to complete its scan (approximately 20 seconds). When scanning starts, the ‘Scan’ button will change to ‘Stop’, and if needed you can click on this button to stop the process. Once scanning is complete, all discovered devices will be displayed in the list box, with Name, Address, Active status, and PIN information.
If the discovered device has been given a unique Name by its owner, that name is used to identify it along with its Bluetooth Address. To see the Address of the Bluetooth radio in your netpad, click on the Property tab of the Bluetooth Controls menu (see “Property Menu Page” on page 136). Note:
During scanning, addresses are scanned for first, and then the names. Therefore, for remote devices that are not in good Bluetooth radio coverage, the scanning process may complete without retrieving all the names.
The Active column indicates whether any service is activated for that device. When a service is activated, the device will show up on the list even when it is not detected during the scan. The PIN column indicates whether you have a PIN (password) set for the device. At this point you can either query for services or set the PIN for each device. Once you highlight a device in the list box, both the Services and Set PIN buttons become available.
132
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 159
Chapter 7: Configuring Communications netpad Bluetooth Settings
Services A discovered device may display several service profiles that it can use to communicate, and you will want to activate the type you need. Supported profiles that can be activated include: DUN (Dial-Up Networking service), Printer (serial service), and LANPPP (LANAccessUsingPPP service). ASync (ActiveSync) is another available profile - for connection details, refer to “Connecting Via Bluetooth” on page 55. To start the service scan, highlight a device (for example, BELKIN_00db7...) in the Devices menu list, then click on the Services button or double-click on the entry. Note:
If the remote device is out of reach or turned off, it could take a long time for the Services dialogue box to come up, and it will appear frozen.
When the device’s service profiles are displayed in the Services list box, highlight the desired service and right-click (or press the space bar) to access the activation options, then click on Active, Authenticate, or Encrypt as required. Once the service is successfully activated, the assigned port (if applicable) will appear in the Port column of the Services list box. You can choose to use BSP or COM as the port name (see “Property Menu Page” on page 136). BSP is the latest Microsoft Bluetooth stack standard, but older applications assume serial ports are COM. When using COM as the port name, the Bluetooth manager will try to find and use a free port between COM7 and COM9. When using BSP as the port name, BSP2 to BSP9 are available for use. The port is available as soon as it is activated. Notes: netpad will automatically assign COM8 to the Printer profile. The CH column shows the RFCOMM channel of the service IF the service is RFCOMM-based. This information is not generally needed except for debugging purposes. Psion Teklogix netpad Windows CE .NET 4.2 User Manual
133
Page 160
Chapter 7: Configuring Communications netpad Bluetooth Settings The Authenticate and Encrypt options can be changed only before activation. To change those after activation, deactivate the service first, then change the options. Once a service is activated, all the information regarding the service, including the RFCOMM channel number, is saved in the registry. (Some remote devices may change their RFCOMM channel numbers when they reboot, so your saved setting may not work when the remote device is rebooted. In that case, you must deactivate the service and reactivate it to detect the current RFCOMM channel.)
Set PIN PINs can be set for each device by pressing the Set PIN button in the Devices menu, or you can skip this step and try to connect to the device first (see page 135). Important:
The remote device must have authentication enabled, otherwise the PIN authentication will fail.
Highlight a device, click on the Set Pin button, and enter the PIN.
You will receive a message, either that the PIN has been successfully validated, or the warning message shown below.
134
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 161
Chapter 7: Configuring Communications netpad Bluetooth Settings After the PIN has been validated, you will see an asterisk (*) in the PIN column in the Devices list box, indicating that this device has a PIN set. Once a PIN is entered, it is saved in the registry. To remove the PIN, press Set PIN, then <Enter>.
If the netpad tries to connect with a remote device for which no PIN has been set but requires a PIN, and has Authentication enabled, you will be prompted to verify the PIN. The Authentication Request dialogue will appear. Enter the PIN, press OK, and the devices will be connected.
7.4.1.2
Servers Menu Page
The Bluetooth connection is initiated from your netpad to the remote device, therefore the netpad is called the ‘client’ and the remote is called the ‘server’. The Servers menu shows the server profiles that can be activated in your netpad. There is currently one server profile available: Serial. Place a checkmark in the checkbox to activate the server and it will show the associated port name beside the server name. The port name also follows the convention under the Property menu (see “Section 7.4.1.3 Property Menu Page” on page 136). Psion Teklogix netpad Windows CE .NET 4.2 User Manual
135
Page 162
Chapter 7: Configuring Communications netpad Bluetooth Settings Once you activate a server profile, it is recommended that the netpad is rebooted before you try to bond from a server. You don't have to reboot when you're deactivating a server.
7.4.1.3
Property Menu Page
The Property menu page shows information about your netpad, and provides some port options.
The Device Name field shows the device name of your netpad. This name can be changed (see the Note on page 137). Device Class shows the Class of Device (e.g. desktop, hand-held), which is always set to Handheld. Local Bluetooth Address shows the address of your netpad radio.
136
Psion Teklogix netpad Windows CE .NET 4.2 User Manual