The text of a manual · part 12 of 26
netpad Windows CE .NET 4.2 User Manual: Configuring The netpad 4, pages 91 to 98
Pages 91 to 98 of 230, from netpad Windows CE .NET 4.2 User Manual
The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Teklogix NetPad 5510, Teklogix NetPad 5520, Psion NetPad 5510 and Psion NetPad 5520
Page 91
Chapter 4: Configuring The netpad Bar Codes
Suffix Char This character, if non-zero, is added after a successfully decoded bar code. Enter the desired character, or enter a value of 00 (zero) if no prefix is to be added. The default character is 00 and is input with the <Esc> key. To append a control character (in the range of 0 to 32 ASCII) as a prefix, press the <Ctrl> key and the corresponding letter (a=0, b=1, c=2, etc.).
Strip Leading This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added. Note:
1.The appended character is treated as any other keyboard character. For example, if <Tab> is pressed, the usual action for that key is performed.
Strip Trailing The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.
DECODED SETTINGS Trioptic C39 Trioptic Code 39 symbols contain six characters. Trioptic C39 and C39 Full ASCII (see below) should not be enabled simultaneously. Turn this parameter OFF if C39 Full ASCII is ON.
Convert C39 to C32 Code 32 is a variant of Code 39 that is used by some industries. If this parameter is ON, Code 39 must be enabled.
C32 Prefix If this parameter is ON, the prefix character “A” is added to the Code 32 bar code. If this parameter is ON, Convert C39 to C32 must be enabled.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
65
Page 92
Chapter 4: Configuring The netpad Bar Codes
C39 Full ASCII If this parameter is ON, the ASCII character set assigns a code of letters, punctuation marks, numerals, and most control keystrokes to the keyboard. The bar code special characters $ + % / are used as escape characters. C39 Full ASCII interprets the combination of an escape character and the following Code 39 character as an equivalent ASCII character. Note:
C39 Full ASCII and Trioptic C39 (see above) should not be enabled simultaneously. Turn this parameter OFF if Trioptic C39 is ON.
C39 Check Digit Verify If this parameter is enabled, the scanner checks the integrity of all Code 39 symbols to verify that the data includes a module 43 check digit. Only Code 39 symbols that contain a module 43 check digit are decoded when this feature is ON.
Xmit C39 Check Digit If this parameter is ON, the check digit is included with the decoded bar code data.
Set Lengths The length of a code refers to the number of characters (human readable characters) that the code contains, including check digit(s) and any start or stop characters. Lengths may be set for any length, or for one or two discrete lengths. Length 1 This option limits decodes to only those symbols of the selected length. Length 2 This option limits decodes to only those symbols of either of two selected lengths.
66
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 93
Chapter 4: Configuring The netpad Bar Codes
4.3.2.2
Code 128
Figure 4.5 Code 128 Bar Code Settings
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64.
DECODED SETTINGS USS-128 When using Code 128, you can choose the variation or type of bar code variation the scanner will recognize. The options are: USS-128, UCC/EAN-128, or ISBT 128.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
67
Page 94
Chapter 4: Configuring The netpad Bar Codes
4.3.2.3
EAN 13
Figure 4.6 EAN 13 Bar Code Settings
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64.
4.3.2.4
EAN 8
Figure 4.7 EAN 8 Bar Code Settings
68
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 95
Chapter 4: Configuring The netpad Bar Codes
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64.
DECODED SETTINGS EAN-8 Zero Extend When this parameter is ON, five zeros are prefixed to the decoded EAN-8 symbols to make them compatible in format with EAN-13 symbols. Disabling the option returns the EAN-8 symbols to their normal format.
Convert EAN-8 to EAN-13 Type When EAN-8 Zero Extend (above) is enabled, this parameter provides the option of labelling the extended symbol as either EAN-13 or EAN-8 bar code. If EAN-8 Zero Extend is disabled, this option has no effect.
4.3.2.5
UPC/EAN
Figure 4.8 UPC/EAN Bar Code Settings
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64. Psion Teklogix netpad Windows CE .NET 4.2 User Manual
69
Page 96
Chapter 4: Configuring The netpad Bar Codes
DECODED SETTINGS Decode Supplementals Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g. UPC A+2, UPC E+2, EAN 8+2). Three options are available: Ignore If the scanner comes across a UPC/EAN plus supplemental symbol, the UPC/EAN is decoded, while the supplemental characters are ignored. Decode If the scanner comes across a UPC/EAN plus supplemental symbol, UPC/EAN symbols without supplemental characters are not decoded. Auto-discriminate This parameter enables the scanner to differentiate and decode UPC/EAN symbols with or without supplementals. This option should be used in conjunction with Supplemental Redundancy, below. Note:
To minimize possible invalid data transmissions, select either the Ignore or Decode option when possible.
Supplemental Redundancy With Auto-discriminate enabled, this parameter limits the number of times a symbol without supplementals will be decoded before transmission. The options are: 5 times, 7 times, 10 times, or 15 times. Five or above is recommended when scanning a mixture of bar codes with and without supplementals.
UPC/EAN Coupon Code If this parameter is ON, the scanner can decode UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 supplemental characters, and UPC-A/EAN 128 bar codes. The Auto-discriminate option under Decode Supplementals must be enabled.
UPC/EAN Security Level There are four Levels of decode security for UPC/EAN bar codes: 0 to 3. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, therefore only choose the level of security needed for the application. 70
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
Page 97
Chapter 4: Configuring The netpad Bar Codes Level: 0 This is the default setting. The scanner operates in its most aggressive state while providing sufficient security in decoding “in-spec” UPC/EAN bar codes. Level: 1 As bar code quality diminishes, certain characters become prone to mis-decodes before others (i.e. 1, 2, 7, 8). Where the mis-decodes of poorly printed bar codes are limited to these characters, select this security level. Level: 2 Where the mis-decodes of poorly printed bar codes are not limited to characters 1, 2, 7, 8, select this security level. Level: 3 When security Level: 2 has not been successful with mis-decodes, select security Level: 3. This security level is an extreme measure against mis-decoding bar codes that are severely out of specification. Level: 3 severely impairs the scanner’s decoding ability, so improve bar code quality whenever possible.
4.3.2.6
UPC A
Figure 4.9 UPC A Bar Code Settings
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64.
Psion Teklogix netpad Windows CE .NET 4.2 User Manual
71
Page 98
Chapter 4: Configuring The netpad Bar Codes
DECODED SETTINGS Xmit UPC-A Check Digit If this parameter is ON, the check digit is included with the decoded bar code data.
UPC-A Preamble For this parameter, if the System Char preamble is selected, the number system character is included with the decoded bar code data. If the System Char + Ctry Code preamble is selected, the number system character and country code are included with the decoded bar code data.
4.3.2.7
UPC E
Figure 4.10 UPC E Bar Code Settings
FIELD SIZE / CHARS For the parameter settings in this menu, please refer to “FIELD SIZE / CHARS” on page 64.
DECODED SETTINGS Xmit UPC-E Check Digit If this parameter is ON, the check digit is included with the decoded bar code data. 72
Psion Teklogix netpad Windows CE .NET 4.2 User Manual