Page 183

Chapter 11

Product Specifications Imager Product Specifications Parameter

Specification

Dimensions (Typical): Height

7.5”/190 mm

Length

4.5”/115 mm

Width

3.0”/75 mm

Weight

11 ounces/312 g (without cable)

Aimer: Illumination LEDs

626nm +30nm

Aiming LEDs

526nm +30nm

Image

VGA, 640x480 or VGA, 752x480 Binary, TIFF, or JPEG output.

Skew Angle

±40 degrees

Pitch Angle

±40 degrees

Horizontal Velocity

2 inches (5 cm) per second

Scan Contrast

45% minimum for Matrix codes, 37.5% minimum for all others

Voltage Requirements

4.5 - 14 VDC at imager

Operating Current (Maximum)

Interlaced aiming mode : 470mA @5V Concurrent aiming mode : 700 mA @5V

Standby Current (Maximum)

Normal mode: 100 mA @5V Low power mode : 55 mA @5V

Product Reference Guide

11-1

Page 184

Product Specifications Power Supply: Maximum 100mV peak to peak, 10 to 100 kHz Noise Rejection Mechanical Shock

50 drops from 6.5 feet (2 meters) to concrete -22° F to 122° F (-30° C to +50° C)

Contaminants Spray/rain Dust/particulate

Imaging Scanners: Spray/rain, IEC 529-IPX5 Dust/particulate, IEC 529-IP6X

Temperature Ranges: Operating

-22° F to +122° F (-30° C to +50° C) Corded -4° F to +122° F (-20° C to +50° C) RF

Storage

-40° F to +140° F (-40° C to + 60°C)

Ambient Light Immunity Humidity Beeper/Speaker

11-2

Up to 40,000 LUX in sunlight - typical 0 to 95% non-condensing

90 dBA for operator at a distance of 19” (50cm) - typical

PowerScan® 7000 2D

Page 185

Standard Cable Pinouts (Primary Interface Cables)

Standard Cable Pinouts (Primary Interface Cables) Serial Output

10 Pin RJ41 Modular Plug connects to the imager handle

1

2 CTS 3 4 RTS 5 RXD 6 TXD 7 8 VCC_IN 9 GND 10 Cable Select

Product Reference Guide

11-3

Page 186

Product Specifications

Standard Cable Pinouts USB

1

2 3 4 D5 6 D+ 7 8 VBUS_VIN 9 GND 10 Cable Select

10 Pin Modular Plug connects to the imager handle

UKBW

1 2 KB Data 3 PC Clk 4 KB Clk 5 6 PC Data 7 8 VIN 9 GND 10 Cable select

11-4

10 Pin Modular Plug connects to the imager handle