The text of a manual · part 2 of 23
PowerScan 7000 2D Imager Product Reference Guide: Getting Started
Pages 9 to 18 of 204, from PowerScan 7000 2D Imager Product Reference Guide
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic 7000 (P70) and PSC 7000 (P70)
Page 9
Chapter 1
Getting Started The PowerScan® 7000 2D imager marks a new performance level for handheld area imagers. They deliver aggressive read rates and depths of field on 1D, stacked linear, and matrix codes. This aggressiveness applies even in challenging reading environments where low lighting conditions and poor quality might make it difficult to read bar codes. You can rest assured your investment will continue to supply years of use by reading any bar codes you require, now or in the future. Designed for today’s demanding commercial and industrial environments, the scanner offers superior image quality, speed, durability, and the ability to read poor quality bar codes. The unit is comfortable to hold, easy to use, rugged, and excellent for the most demanding applications.
About This Manual This Product Reference Guide (PRG) provides programming instructions for the imager, plus product specifications and dimensions. For installation, maintenance, troubleshooting and warranty information, see the Quick Reference Guide (QRG). Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual. The imager is factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. An asterisk (*) next to an option indicates the default setting.
Product Reference Guide
1-1
Page 10
Getting Started
Manual Conventions The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the imager: Notes contain information necessary for properly diagnosing, repairing and operating the imager. NOTE
The CAUTION symbol advises you of actions that could damage equipment or property. CAUTION
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below.
Standard Product Default Settings
The chart Menu Commands, starting on page 10-6 lists the factory default settings for each of the menu commands (indicated by an asterisk (*) on the following programming pages.
1-2
PowerScan® 7000 2D
Page 11
LED and Beeper Indications
LED and Beeper Indications The imager is equipped with a beeper (speaker) and two indicator LEDs; one green and one yellow. These indicators “beep” or flash when certain actions take place:
NOTE
Some LED and Beeper indications are user-configurable for volume, pitch, quantity, duration, enable/disable, etc. Those listed in the following table assume the feature is enabled. See the Product Reference Guide (PRG) for detailed programming information.
Condition Powering On UKBW/RS-232 Models (using UKBW interface) Powering On UKBW/RS-232 Models (using RS-232 interface) Powering On All Other Models Good Read Error Indication
Green LED
Beeper
2 normal flashes and 2 fast flashes (+ 1 normal flash with Smart cable)
One Beep
2 normal flashes and 1 long flash
One Beep
Bright Green Flash
One Beep
1 - 9 Bright Green Flash(es)a Green Flash
1 - 9 Beep(s)a
Yellow LED
Beeper
Yellow LED on steady until trigger is pulled
None
Condition Ready to Operate
Special Beep a. Good Read indications are synchronous. That is, if Good Read beeps are set via programming to five (for example), the Good Read LED will also flash five times.
Product Reference Guide
1-3
Page 12
Getting Started
Plug and Play Plug and Play bar codes provide instant imager set up for commonly used interfaces. After you scan one of the codes, power cycle the host terminal to have the interface in effect. NOTE
Connecting the imager with an RS-232 Serial Port These instructions are for use with the RS-232 cable. This includes both Power Off the Terminal (P.O.T.) and external power. NOTE
1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the imager. For the imager to work properly, you must have the correct cable for your type of terminal/computer. NOTE
Cable Connector Retainer Boss
Captive Screws
1-4
For 220-230 VAC adapters, the cord must be facing down as shown in the illustration. If installed upwards, it will pose an undue strain on the socket outlet.
PowerScan® 7000 2D
Page 13
Plug and Play
3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 4. If the terminal does not support Power Off the Terminal (P.O.T.) connections plug the power supply into the host connector and the AC outlet. 5. Once the imager has been fully connected, power up the computer. All communication parameters between the imager and terminal must match for correct data transfer through the serial port using RS-232 protocol. Scanning the RS-232 interface bar code, programs the imager for an RS-232 interface at 115,200 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF.
RS-232 Interface
Connecting the imager with USB This interface applies to USB compatible models only. NOTE
An imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the imager and to the computer.
Captive Screws
B
Cable Connector Retainer Boss
US
Product Reference Guide
1-5
Page 14
Getting Started
2. The imager beeps. 3. Verify imager operation by scanning the part number bar code from the back cover of this manual.
NOTE
The following USB “Plug and Play” codes are supported on specific models. Refer to the Product Reference Guide to determine if this interface applies to your unit.
For additional USB programming and technical information, visit the website listed on the back cover of this manual.
IBM SurePos Scan one of the following “Plug and Play” codes to program the imager for IBM SurePos (USB Hand Held imager) or IBM SurePos (USB Tabletop imager). After scanning one of these codes, you must power cycle the cash register NOTE
IBM SurePos (USB Hand Held imager) Interface IBM SurePos (USB Tabletop imager) Interface
1-6
PowerScan® 7000 2D
Page 15
Plug and Play
Each bar code above also programs the following suffixes for each symbology: Symbology EAN-8 EAN-13 UPC-A UPC-E Code 39 Interleaved 2 of 5 Code 128
NOTE
Suffix 0C 16 0D 0A 00 0A 0B 00 0D 0B 00 18 0B
The following USB “Plug and Play” codes (USB Keyboard - PC, USB Keyboard - Mac, and USB HID) are supported on specific imager models. Check your model type to determine if this interface applies to your unit.
USB PC Keyboard or USB Macintosh Keyboard Scan one of the following codes to program the imager for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes adds a CR and selects the terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard - 125).
USB Keyboard (PC) USB Keyboard (Mac)
Product Reference Guide
1-7
Page 16
Getting Started
USB HID Scan the following code to program the imager for USB HID bar code imagers. Scanning this code changes the terminal ID to 131.
USB HID Bar Code imager
USB COM Port Emulation Scan the following code to program the imager to emulate a regular RS232-based COM port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the website listed on the back cover of this manual. The driver will use the next available COM port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically use a class driver. Scanning the code below changes the terminal ID to 130.
USB COM Port Emulation
No extra configuration (e.g., baud rate) is necessary. NOTE
CTS/RTS Emulation
On * Off
1-8
PowerScan® 7000 2D
Page 17
Plug and Play
ACK/NAK Mode
On * Off
Reference the Product Reference Guide (PRG) for more information about keyboard support. NOTE
Connecting the imager in Universal Keyboard Wedge mode The Universal Keyboard Wedge (UKBW) model allows an RS-232 transmission or Keyboard Wedge mode according to the type of cable connected. Contact Datalogic or your dealer for cable and/or power supply part numbers. 1. Turn off power to the terminal/computer. 2. Connect the keyboard wedge interface cable to the imager. For the imager to work properly, you must have the correct cable for your type of terminal/computer. NOTE
Product Reference Guide
1-9
Page 18
Getting Started
3. Connect one end of the Y cable to the keyboard cable and the other to the keyboard port on the host/computer.
Cable Connector Retainer Boss K ey bo ard
Captive Screws
4. Scan the following bar code to program the imager for the UKBW interface.
~ p Universal a p 2 Keyboard 3 2 ; Wedge 2 3 (UKBW) 2 C T Interface S 1 ³
1-10
.
PowerScan® 7000 2D