Page 165
Menu Commands
Setting * Indicates default
Selection
LED Power Level
Illumination Lights
3-10
Low (50%)
PWRLDC50
3-10
*High (100%)
PWRLDC100
3-10
*Lights On
SCNLED1
3-11
Lights Off
SCNLED0
3-11
SDRTIM##### #
3-11
SCNDLY200
3-12
400 milliseconds
SCNDLY400
3-12
*Off (no delay)
SCNDLY0
3-12
Range 0 - 4,000 ms
SCNDLY####
3-12
Off
SCNAIM0
3-14
*Concurrent
SCNAIM1
3-14
Interlaced
SCNAIM2
3-14
Centering On
DECWIN1
3-16
*Centering Off
DECWIN0
3-16
Left of Centering Window (*40%)
DECLFT
3-16
Right of Centering Window (*60%)
DECRGT
3-16
Top of Centering Window (*40%)
DECTOP
3-16
Bottom of Centering Window (*60%)
DECBOT
3-16
Full Omnidirectional (Default for 2D imagers)
DECMOD0
3-16
Quick Omnidirectional
DECMOD1
3-17
Advanced Linear Decoding (Default for PDF imagers)
DECMOD2
3-17
Enter Sequence
SEQBLK
3-21
Default Sequence
SEQDFT
3-21
(*120,000 ms) 200 milliseconds
Aimer Modes
Centering Window
Decode Search Mode
Output Sequence Editor
Page
PWRLDC0
Range 0 - 999,999 ms
User-Specified Aimer Delay
# Indicates a numeric entry
Off
Imager Time-Out
Aimer Delay
Serial Command
Product Reference Guide
10-11
Page 166
Serial Programming Commands
Setting * Indicates default
Selection
Require Output Sequence Multiple Symbols No Read Print Weight Video Reverse
Working Orientation
Serial Command # Indicates a numeric entry
Page
Required
SEQ_EN2
3-21
On/Not Required
SEQ_EN1
3-21
*Off
SEQ_EN0
3-21
On
SHOTGN1
3-22
*Off
SHOTGN0
3-22
On
SHWNRD1
3-22
*Off
SHWNRD0
3-22
Set Print Weight (1-7)
PRTWGT
3-23
*Default (4)
PRTWGT4
3-23
On
VIDREV1
3-23
*Off
VIDREV0
3-23
*Upright
ROTATN0
3-24
Rotate Clockwise 90°
ROTATN1
3-24
Upside Down
ROTATN2
3-24
Rotate Counterclockwise 90°
ROTATN3
3-24
VSUFCR
4-4
Add Prefix
PREBK2##
4-5
Clear One Prefix
PRECL2
4-5
Prefix/Suffix Selections Add CR Suffix to All Symbologies Prefix
Suffix Function Code Transmit Intercharacter Delay User Specified Intercharacter Delay
10-12
Clear All Prefixes
PRECA2
4-5
Add Suffix
SUFBK2##
4-5
Clear One Suffix
SUFCL2
4-5
Clear All Suffixes
SUFCA2
4-5
*Enable
RMVFNC0
4-5
Disable
RMVFNC1
4-5
Range 0 - 495 ms
DLYCHR##
4-6
DLYCRX##
4-7
DLY_XX###
4-7
Delay Length (0 - 495 ms) Character to Trigger Delay
PowerScan® 7000 2D
Page 167
Menu Commands
Setting * Indicates default
Selection
Serial Command # Indicates a numeric entry
Page
Interfunction Delay
Range 0 - 495 ms
DLYFNC##
4-7
Intermessage Delay
Range 0 - 495 ms
DLYMSG##
4-8
Data Formatter Selections
Data Format Editor
Data Formatter
Alternate Data Formats
*Default Data Format (None)
DFMDF3
5-5
Enter Data Format
DFMBK3##
5-5
Clear One Data Format
DFMCL3
5-5
Clear All Data Formats
DFMCA3
5-5
Save
MNUSAV
5-5
Discard
MNUABT
5-5
Off
DFM_EN0
5-5
*On, but Not Required
DFM_EN1
5-5
On, Required
DFM_EN2
5-5
1
VSAF_1
5-6
2
VSAF_2
5-6
3
VSAF_3
5-6
All Symbologies Off
ALLENA0
6-2
All Symbologies On
ALLENA1
6-2
CBRDFT
6-3
Off
CBRENA0
6-3
*On
CBRENA1
6-3
*Don’t Transmit
CBRSSX0
6-3
Transmit
CBRSSX1
6-3
*No Check Char.
CBRCK20
6-4
Validate, But Don’t Transmit
CBRCK21
6-4
Validate, and Transmit
CBRCK22
6-4
Symbologies All Symbologies
Default All Codabar Codabar Settings Codabar Codabar Start/ Stop Char. Codabar Check Char.
Product Reference Guide
10-13
Page 168
Serial Programming Commands
Setting * Indicates default
Selection
Codabar Concatenation Codabar Message Length
Serial Command # Indicates a numeric entry
Page
*Off
CBRCCT0
6-4
On
CBRCCT1
6-4
Require
CBRCCT2
6-4
Minimum (2 - 60) *4
CBRMIN##
6-5
Maximum (2 - 60) *60
CBRMAX##
6-5
C39DFT
6-5
Off
C39ENA0
6-5
Default All Code 39 Code 39 Settings Code 39 Code 39 Start/ Stop Char.
*On
C39ENA1
6-5
*Don’t Transmit
C39SSX0
6-5
Transmit
C39SSX1
6-5
*No Check Char.
C39CK20
6-6
C39CK21
6-6
C39CK22
6-6
Minimum (0 - 48) *0
C39MIN##
6-6
Maximum (0 - 48) *48
C39MAX##
6-6
*Off
C39APP0
6-7
On
C39APP1
6-7
*Off
C39B320
6-7
On
C39B321
6-7
*Off
C39ASC0
6-8
On
C39ASC1
6-8
Code 39 Code Page
C39DCP
6-9
I25DFT
6-9
Off
I25ENA0
6-11
*On
I25ENA1
6-11
Validate, But Don’t Code 39 Check Char.
Transmit Validate, and Transmit
Code 39 Message Length Code 39 Append Code 32 Pharmaceutical (PARAF) Code 39 Full ASCII
Default All Interleaved Interleaved 2 of 5 2 of 5 Settings Interleaved 2 of 5
10-14
PowerScan® 7000 2D
Page 169
Menu Commands
Setting * Indicates default
Selection
*No Check Char. Interleaved 2 of 5 Check Digit
Interleaved 2 of 5 Message Length
Serial Command # Indicates a numeric entry
Page
I25CK20
6-10
I25CK21
6-10
Validate, and Transmit
I25CK22
6-10
Minimum (2 - 80) *4
I25MIN##
6-10
Maximum (2 - 80) *80
I25MAX##
6-10
C93DFT
6-11
Off
C93ENA0
6-11
Validate, But Don’t Transmit
Default All Code 93 Code 93 Settings Code 93 Code 93 Message Length
*On
C93ENA1
6-11
Minimum (0 - 80) *0
C93MIN##
6-11
Maximum (0 - 80) *80
C93MAX##
6-11
Code 93 Code Page
C93DCP
6-11
R25DFT
6-12
*Off
R25ENA0
6-12
On
R25ENA1
6-12
Minimum (1 - 48) *4
R25MIN##
6-12
Maximum (1 - 48) *48
R25MAX##
6-12
A25DFT
6-13
*Off
A25ENA0
6-13
On
A25ENA1
6-13
Minimum (1 - 48) *4
A25MIN##
6-13
Maximum (1 - 48) *48
A25MAX##
6-13
X25DFT
6-14
Default All Code 2 of 5 Code 2 of 5 Settings Code 2 of 5 Code 2 of 5 Message Length
Default All IATA Code 2 of 5 IATA Code 2 of 5 Settings IATA Code 2 of 5 IATA Code 2 of 5 Message Length
Default All Matrix 2 of 5 Matrix 2 of 5 Settings
Product Reference Guide
10-15
Page 170
Serial Programming Commands
Setting * Indicates default
Selection
Matrix 2 of 5 Matrix 2 of 5 Message Length
Serial Command # Indicates a numeric entry
Page
*Off
X25ENA0
6-14
On
X25ENA1
6-14
Minimum (1 - 80) *4
X25MIN##
6-14
Maximum (1 - 80) *80
X25MAX##
6-14
C11DFT
6-14
*Off
C11ENA0
6-14
On
C11ENA1
6-14
Default All Code 11 Code 11 Settings Code 11 Code 11 Check Digits Required
1 Check Digit
C11CK20
6-15
*2 Check Digits
C11CK21
6-15
Code 11 Message Length
Minimum (1 - 80) *4
C11MIN##
6-15
Maximum (1 - 80) *80
C11MAX##
6-15
128DFT
6-16
Off
128ENA0
6-16
*On
128ENA1
6-16
ISBT Concatenation
*Off
ISBENA0
6-16
On
ISBENA1
6-16
Code 128 Message Length
Minimum (0 - 80) *0
128MIN##
6-17
Maximum (0 - 80) *80
128MAX##
6-17
Code 128 Code Page (*2)
128DCP##
6-17
TELDFT
6-17
*Off
TELENA0
6-18
On
TELENA1
6-18
*AIM Telepen Output
TELOLD0
6-18
Default All Code 128 Code 128 Settings Code 128
Code 128 Code Page
Default All Telepen Telepen Settings Telepen Telepen Output Telepen Message Length 10-16
Original Telepen Output
TELOLD1
6-18
Minimum (1 - 60) *1
TELMIN##
6-18
Maximum (1 - 60) *60
TELMAX##
6-18
PowerScan® 7000 2D
Page 171
Menu Commands
Setting * Indicates default
Selection
Serial Command # Indicates a numeric entry
Page
Default All UPC-A
UPADFT
6-19
Off
UPAENA0
6-19
*On
UPAENA1
6-19
UPC-A Settings UPC-A UPC-A Check Digit
Off
UPACKX0
6-19
*On
UPACKX1
6-19
UPC-A Number System
Off
UPANSX0
6-19
*On
UPANSX1
6-19
UPC-A 2 Digit Addenda
*Off
UPAAD20
6-20
On
UPAAD21
6-20
UPC-A 5 Digit Addenda
*Off
UPAAD50
6-20
On
UPAAD51
6-20
UPC-A Addenda Required
*Not Required
UPAARQ0
6-20
Required
UPAARQ1
6-20
UPC-A Addenda
Off
UPAADS0
6-20
Separator
*On
UPAADS1
6-20
UPC-A/EAN-13 with Extended Coupon Code
*On
CPNENA1
6-21
Off
CPNENA0
6-21
UPEDFT
6-21
Off
UPEEN00
6-21
*On
UPEEN01
6-21
*Off
UPEEXP0
6-21
Default All UPC-E UPC-E0 Settings UPC-E0 UPC-E0 Expand
On
UPEEXP1
6-21
UPC-E0 Addenda Required
Required
UPEARQ1
6-22
*Not Required
UPEARQ0
6-22
UPC-E0 Addenda Separator
*On
UPEADS1
6-22
Off
UPEADS0
6-22
Product Reference Guide
10-17
Page 172
Serial Programming Commands
Setting * Indicates default
Selection
Serial Command # Indicates a numeric entry
Page
UPC-E0 Check Digit
Off
UPECKX0
6-22
*On
UPECKX1
6-22
UPC-E0 Number System
Off
UPENSX0
6-23
UPC-E0 Addenda
*On
UPENSX1
6-23
2 Digit Addenda On
UPEAD21
6-23
*2 Digit Addenda Off
UPEAD20
6-23
5 Digit Addenda On
UPEAD51
6-23
*5 Digit Addenda Off
UPEAD50
6-23
*Off
UPEEN10
6-23
On
UPEEN11
6-23
E13DFT
6-24
Off
E13ENA0
6-24
*On
E13ENA1
6-24
Off
E13CKX0
6-24
*On
E13CKX1
6-24
2 Digit Addenda On
E13AD21
6-24
*2 Digit Addenda Off
E13AD20
6-24
5 Digit Addenda On
E13AD51
6-24
*5 Digit Addenda Off
E13AD50
6-24
EAN/JAN-13 Addenda Required
*Not Required
E13ARQ0
6-25
Required
E13ARQ1
6-25
EAN/JAN-13 Addenda
Off
E13ADS0
6-25
*On
E13ADS1
6-25
*Off
E13ISB0
6-25
On
E13ISB1
6-25
EA8DFT
6-26
UPC-E1
Default All EAN/ EAN/JAN-13 JAN Settings EAN/JAN-13 EAN/JAN-13 Check Digit EAN/JAN-13 2 Digit Addenda
Separator ISBN Translate
Default All EAN/ EAN/JAN-8 JAN 8 Settings
10-18
PowerScan® 7000 2D
Page 173
Menu Commands
Setting * Indicates default
Selection
EAN/JAN-8 EAN/JAN-8 Check Digit
Serial Command # Indicates a numeric entry
Page
Off
EA8ENA0
6-26
*On
EA8ENA1
6-26
Off
EA8CKX0
6-26
*On
EA8CKX1
6-26
*2 Digit Addenda Off
EA8AD20
6-26
EAN/JAN-8 Addenda
2 Digit Addenda On
EA8AD21
6-26
*5 Digit Addenda Off
EA8AD50
6-26
5 Digit Addenda On
EA8AD51
6-26
EAN/JAN-8 Addenda Required
*Not Required
EA8ARQ0
6-27
Required
EA8ARQ1
6-27
EAN/JAN-8 Addenda
Off
EA8ADS0
6-27
*On
EA8ADS1
6-27
Separator MSI
Default All MSI Settings
MSIDFT
6-28
*Off
MSIENA0
6-28
On
MSIENA1
6-28
*Validate Type 10, but Don’t Transmit
MSICHK0
6-28
Validate Type 10 and Transmit
MSICHK1
6-28
MSI Message Length
Minimum (4 - 48) *4
MSIMIN##
6-29
Maximum (4 - 48) *48
MSIMAX##
6-29
Plessey Code
Default All Plessey Settings
PLSDFT
6-29
*Off
PLSENA0
6-29
On
PLSENA1
6-29
Minimum (4 - 48) *4
PLSMIN##
6-29
Maximum (4 - 48) *48
PLSMAX##
6-29
RSSDFT
6-30
Off
RSSENA0
6-30
*On
RSSENA1
6-30
MSI
MSI Check Character
Plessey Code Plessey Message Length
Default All RSS-14 RSS-14 Settings RSS-14
Product Reference Guide
10-19
Page 174
Serial Programming Commands
Setting * Indicates default
Selection
Serial Command # Indicates a numeric entry
Page
Default All RSS-14 RSS Limited
RSLDFT
6-30
Off
RSLENA0
6-30
*On
RSLENA1
6-30
RSEDFT
6-31
Off
RSEENA0
6-31
*On
RSEENA1
6-31
RSS Expanded Msg. Length
Minimum (4 - 74) *4
RSEMIN##
6-31
Maximum (4 - 74) *74
RSEMAX##
6-31
PosiCode
Default All PosiCode Settings
POSDFT
6-32
Off
POSENA0
6-32
*On
POSENA1
6-32
A and B On
POSLIM0
6-32
A and B and Limited A On
POSLIM1
6-32
*A and B and Limited B On
POSLIM2
6-32
Minimum (2 - 80) *4
POSMIN##
6-32
Limited Settings RSS Limited
Default All RSS-14 RSS Expanded Expanded Settings RSS Expanded
PosiCode
PosiCode Msg. Length Trioptic Code Codablock F Codablock F Codablock F Msg. Length Code 16K Code 16K
10-20
Maximum (2 - 80) *48
POSMAX##
6-32
*Off
TRIENA0
6-33
On
TRIENA1
6-33
Default All Codablock F Settings
CBFDFT
6-33
*Off
CBFENA0
6-33
On
CBFENA1
6-33
Minimum (1 - 2048) *1
CBFMIN####
6-33
Maximum (1 - 2048) *2048
CBFMAX####
6-33
Default All Code 16K Settings
16KDFT
6-34
*Off
16KENA0
6-34
On
16KENA1
6-34
PowerScan® 7000 2D