Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 23

PowerScan 7000 2D Imager Product Reference Guide: Symbologies, pages 99 to 108

Pages 99 to 108 of 204, from PowerScan 7000 2D Imager Product Reference Guide

The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 7000 (P70) and PSC 7000 (P70)

Page 99

Linear Symbologies

RSS Expanded < Default All RSS Expanded Settings >

RSS Expanded Enable

* On Off RSS Expanded Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.

Minimum Message Length Maximum Message Length

Product Reference Guide

6-31

Page 100

Symbologies

PosiCode <Default All PosiCode Settings>

PosiCode A and B Enable

* On Off

You have to have PosiCode A and B on to read any of the PosiCode symbologies.

A and B On (No Limited) A and B and Limited A On (Limited B Off) * A and B and Limited B On (Limited A Off) PosiCode Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.

Minimum Message Length Maximum Message Length

6-32

PowerScan® 7000 2D

Page 101

Stacked Symbologies

Trioptic Code If you are going to scan Code 32 Pharmaceutical codes (page 6-7), Trioptic Code must be off. NOTE

Trioptic Code is used for labeling magnetic storage media.

On * Off

Stacked Symbologies Codablock F <Default All Codablock F Settings>

Codablock F Enable

On * Off Codablock F Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.

Minimum Message Length Maximum Message Length Product Reference Guide

6-33

Page 102

Symbologies

Code 16K <Default All Code 16K Settings>

Code 16K Enable

On * Off Code 16K Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160.

Minimum Message Length Maximum Message Length

6-34

PowerScan® 7000 2D

Page 103

Stacked Symbologies

Code 49 <Default All Code 49 Settings>

Code 49 Enable

* On Off Code 49 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81.

Minimum Message Length Maximum Message Length

Product Reference Guide

6-35

Page 104

Symbologies

PDF417 < Default All PDF417 Settings >

PDF417 Enable

* On Off PDF417 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.

Minimum Message Length Maximum Message Length

6-36

PowerScan® 7000 2D

Page 105

Stacked Symbologies

MicroPDF417 < Default All MicroPDF417 Settings >

MicroPDF417 Enable

On * Off MicroPDF417 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.

Minimum Message Length Maximum Message Length

EAN•UCC Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called EAN•UCC Composite symbology. EAN•UCC Composite symbologies allow for the co-existence of symbologies already in use.

On * Off

Product Reference Guide

6-37

Page 106

Symbologies

UPC/EAN Version Scan the UPC/EAN Version On bar code to decode EAN•UCC Composite symbols that have a UPC or EAN linear component. (This does not affect EAN•UCC Composite symbols with a UCC/EAN-128 or RSS linear component.)

UPC/EAN Version On * UPC/EAN Version Off EAN•UCC Composite Code Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435.

Minimum Message Length Maximum Message Length EAN•UCC Emulation

The imager can automatically format the output from any EAN•UCC data carrier to emulate what would be encoded in an equivalent UCC/ EAN-128 or RSS and Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E, EAN-13 and EAN-8, ITF-14, UCC/EAN128, and EAN•UCC RSS and Composites. Data from 2D symbols such as Aztec Code, Data Matrix, or QR Code, which encode a leading FNC1, also invoke EAN•UCC emulation. If UCC/EAN-128 Emula-

6-38

PowerScan® 7000 2D

Page 107

Stacked Symbologies tion is selected, the AIM Symbology Identifier is reported as “]C1”. If RSS Emulation is selected, the AIM Symbology Identifier is reported as “]e0.” Any application that accepts EAN•UCC data can be simplified since it only needs to recognize one data carrier type. Default = No Emulation.

RSS Emulation 128 Emulation * EAN•UCC Emulation Off

TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component. The MicroPDF417 component can only be decoded if TLC39 On is selected. The linear component may be decoded as Code 39 even if TLC39 is off.

On * Off

Product Reference Guide

6-39

Page 108

Symbologies

Postal Codes

NOTE

For best performance when reading a postal symbology, all other postal symbologies should be turned off. The following postal codes can only be read by a full 2D Imager.

Postnet

On * Off Postnet Check Digit Transmit

This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.

Transmit Check Digit * Don’t Transmit Check Digit

6-40