Page 31

Using the Falcon Configuration Utility

13.

Continue following the instructions in the dialog boxes, replacing the first disk with the second, and then the third disk.

14.

When the installation is complete, click on the Finish button in the final window.

Using the Falcon Configuration Utility To start the Falcon Configuration utility, double-click on the FALCON icon in the program group. The first screen that appears is the main menu.

Main Menu This menu provides access to all the configuration settings for the Falcon (Figure 2-1 on page 2-4). Default

1.

Select this option to load the original factory configuration into the Falcon unit. The Configuration utility prepares files to be transferred to the Falcon and opens the Important dialog box (Figure 2-2).

2.

Check the file lists in both sections of the dialog box to see if they are correct and complete.

3.

To add, delete, or rename files, select Cancel from the dialog box.

4.

Use the Custom selection in the main menu to build custom lists. (Refer to page 2-5 through page 2-8 for instructions to create custom configurations.)

5.

If the file lists in the dialog box are correct, make sure the Falcon unit is properly connected to the serial port specified in the Comm Settings dialog box (refer to page 2-20).

6.

Run the ld.bat file on the Falcon.

Advanced User’s Guide

2-3

Page 32

The Falcon Configuration Utility Figure 2-1: The Falcon Configuration Utility Main Menu

7.

Click on the OK button in the Important dialog box (Figure 2-2 on page 2-5).

Custom Select this option to choose or modify configuration files or program files to be loaded into the Falcon unit. See the next section for information on the Custom Configuration menu. Comm Select this option to modify settings for the computer’s serial port. Refer to Settings page 2-20 for information on the Comm Settings dialog box. Transfer Files Select this option to transfer data files between the Falcon and the host computer. Refer to page 2-21 through page 2-24 for information on the File Transfer window.

2-4

Falcon® DOS Portable Terminals

Page 33

Using the Falcon Configuration Utility Figure 2-2: The Important Dialog Box

Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.

The Custom Configuration Menu 1.

Select Custom from the main menu.

2.

An Open dialog box appears (refer to Figure 2-3 on page 2-6).

3.

Use this dialog box to select a configuration file from the Configs folder. z The configuration file contains the information presented when selecting the File Configuration button on the Custom Configuration menu.

Advanced User’s Guide

2-5

Page 34

The Falcon Configuration Utility Figure 2-3: The Open Dialog Box for Selecting a Configuration File

If the Open as read-only check box is selected and changes are made to the configuration settings, use a new file name to save the changes.

4.

When the configuration file is finished loading, a second Open dialog box appears.

5.

Use this dialog box to select a program-settings file from the Progsets folder.

6.

The program-settings file contains the information that will be presented when selecting the Program Settings button on the Custom Configuration menu.

7.

After the program-settings file is loaded, the Custom Configuration menu appears (Figure 2-4 on page 2-7).

File Select this option to choose application files to be loaded into the Falcon. Refer Configuration to page 2-9 through page 2-16 for information about the File Configuration windows. Configure Files Using: This field shows the configuration file that will be used to specify the files that will be loaded into the Falcon. Select the check box to load the files. Deselect it to turn this option off.

2-6

Falcon® DOS Portable Terminals

Page 35

Using the Falcon Configuration Utility Figure 2-4: The Custom Configuration Menu

Program Select this option to view or change settings for bar code symbologies and other Settings programmable Falcon options. Refer to page 2-16 through page 2-20 for information about the Program Settings windows. Program Settings Using: This field shows the program-settings file that will be used. Select the check box to load the program settings. Deselect it to turn this option off. Comm Select this option to view or change serial communications settings for the Settings Falcon. See page 2-20 for information about the Comm Settings dialog box. Download When finished customizing the Falcon configuration, select this option to load the custom configuration into the Falcon. 1.

When selected, the configuration utility prepares files to be transferred to the Falcon and opens the Important dialog box (refer to Figure 2-2).

Advanced User’s Guide

2-7

Page 36

The Falcon Configuration Utility

2.

Make sure the Falcon unit is properly connected to the serial port specified in the Comm Settings dialog box (refer to page 2-20).

3.

Then run the ld.bat file on the Falcon, and select OK in the Important dialog box.

Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.

Done Select this option to return to the main menu. If changes were made to the file configuration or program settings, one or both of the following prompts appear: Figure 2-5: The Prompt for Saving Changes to the Current File Configuration

Figure 2-6: The Prompt for Saving Changes to the Current Program Settings

Yes Select this option to save the changes. A Save As dialog box will open. Use the dialog box to specify the location and name of the new configuration or program-settings file. No Select this option to discard the changes. Cancel Select this option to return to the Custom Configuration menu without saving or discarding the changes.

2-8

Falcon® DOS Portable Terminals

Page 37

Using the Falcon Configuration Utility

The File Configuration Windows 1.

Select File Configuration from the Custom Configuration Menu

2.

The first of three File Configuration windows appears. (Figure 2-7)

Figure 2-7: The First File Configuration Window

3.

Use these windows to choose application files to be loaded into the Falcon.

Configuration File: This field shows the configuration file used to specify the files that will be loaded into the Falcon. Save After adding, editing, or deleting files in the Application Files list, select Save to save the revised list in the current configuration file or in a new one. Browse

1.

Select Browse to use a different configuration file.

2.

An Open dialog box appears.

Advanced User’s Guide

2-9

Page 38

The Falcon Configuration Utility

3.

Use the Open dialog box to choose a configuration file from the Configs folder.

4.

If Browse is selected after making changes in this or any other File Configuration window and the changes are not saved, the prompt shown in Figure 2-8 appears.

Figure 2-8: The File Selection Dialog Box for Adding an Application File

Main Application: This field identifies the default application that will run on the Falcon after completing the installation. Application Files: This field lists the files associated with the main application.

Add Select this option to include other files to be installed on the Falcon unit. The File Selection dialog box opens. Enter path and filename on host PC: Use this field to specify the file to be transferred to the Falcon. Enter path and filename on portable: Use this field to specify the location and name of the file to be transferred to the Falcon. The name can be the same as the original file or it can be given a new name. Download File To: Select this check box to have the specified file downloaded to the specified Falcon models. Main Application: Select this check box to have the specified file be the main application on the specified Falcon models. 2-10

Falcon® DOS Portable Terminals

Page 39

Using the Falcon Configuration Utility Only one file can be selected as the main application for a Falcon model family. To select another file as the main application, highlight the current one in the Application Files list in the File Configuration window, select Edit, and turn off the Main Application switch for that file.

OK Select OK to return to the File Configuration window. The specified source file will appear in the Application Files list. Cancel Select Cancel to return to the File Configuration window without adding a file to the Application Files list. Browse

1.

Select Browse to use a different configuration file.

2.

An Open dialog box appears.

3.

Use the Open dialog box to choose a source file to be included in the custom configuration.

Edit Select a file in the Application Files list and then select Edit to change the source path or destination path for the file. The Edit File Properties dialog box opens. Figure 2-9: The Edit File Properties Dialog Box for an Application File

Delete To delete a file from the Application Files list, select the file in the list and then select Delete. Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.

Advanced User’s Guide

2-11

Page 40

The Falcon Configuration Utility

Next Select Next to view or change additional file-configuration options for the custom installation. Done

1.

Select Done when finished setting file-configuration options for the custom installation.