Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Pelco PT570 Spec Sheet

Spec sheet · Pelco

Pelco PT570 Spec Sheet

Spec sheet2 pagesPDF 91 KB

Both pages are below, each with its text.

Download the PDF91 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A two-page Pelco specification sheet (C330, revised 10-03, from the 2005 spec book) for the PT570P (120 VAC) and PT570-24P (24 VAC) medium duty outdoor pan/tilts and their /PP versions. It gives movement, load, wiring, cable distances, environment, options and the recommended controls, enclosure and mounts.

Device
Medium duty pan/tilt for outdoor camera sites p. 1
Voltage
PT570P: 120 VAC; PT570-24P: 24 VAC p. 1
Maximum load
40 pounds (18.14 kg) p. 1
Movement
0-355° in the horizontal plane; ±90° in the vertical plane p. 2
Drive
Adjustable worm-gear final drives that minimize backlash and prevent wind drift p. 1
Construction
Aluminum, completely sealed for all-weather use p. 1
Environment
Outdoor, -10° to 120°F (-23° to 49°C) p. 2
Heater option
Blanket heater in cover, 75W, for operation to -50°F (-45°C) p. 1, 2
Wiring
6 or 7 unshielded conductors (left, right, up, down, motor common, safety ground); PP option needs 4 more p. 2
Duty cycle
50% duty cycle; 30 minute rating p. 2
Features
Inverted operation, external limit stops, auto/random scan with a suitable control p. 1
Ratings
The sheet states UL Listed, NEMA Type 3R, and CE Class B for the PT570-24P and PT570-24P/PP p. 2
Recommended enclosure
EH4700 Series environmental enclosure p. 1, 2
Controls and mounts
Controls: Coaxitron or Matrix, MPT24DT, MPTAZ Series, RB115, RB24; mounts: PA2000, PM2000, PM2010, ST1, WM2000 p. 2

What this sheet walks you through

  • Maximum control cable distances by wire size p. 2
  • Extending control distance with a 24 VAC control and a relay box p. 2
  • Mounting dimensions in inches and centimeters p. 1

Good to know

  • The cable distances assume both motors running and a 10% voltage drop in the cable. p. 2
  • The PP option requires 4 additional conductors. p. 2

Questions this sheet answers

What voltage does the Pelco PT570 pan/tilt use?

The PT570P runs on 120 VAC and the PT570-24P on 24 VAC. p. 1

How much weight can the PT570 carry?

Up to 40 pounds (18.14 kg). p. 1

Can the PT570 work in very cold weather?

It is rated to -10°F (-23°C); an optional blanket heater allows operation to -50°F (-45°C). p. 1, 2

How far does the PT570 pan and tilt?

0-355° in the horizontal plane and ±90° in the vertical plane. p. 2

The file

Size and text

Pages2
PDF91 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Pelco PT570 Spec Sheet

The text of page 1, from the PDF itself

2005 Spec Book.book Page 245 Wednesday, March 9, 2005 8:50 AM

PRODUCT SPECIFICATION

camera site

PT570P/PT570-24P Pan/Tilt OUTDOOR, MEDIUM DUTY Product Features

  • Easily Serviced
  • Inverted Operation
  • External Limit Stops
  • Outdoor Applications
  • Adjustable Worm-Gear Final Drive
  • 120 VAC or 24 VAC Operation
  • Capable of Auto/Random Scan Operation when Used with Appropriate Control
  • Maximum Load 40 Pounds (18.14 kg)

The PT570P and the PT570-24P are medium duty pan/tilts designed for outdoor applications. Both units feature rugged wormgear final drives to minimize backlash and prevent wind drift. The drives are fully adjustable for wear. Control voltages are 120 VAC for the PT570P and 24 VAC for the PT570-24P. Construction is of aluminum, and the units are completely sealed for all-weather use. The PT570P and PT570-24P will accept a maximum load of 40 pounds (18.14 kg) and are recommended for use with our EH4700 Series environmental enclosures.

Ø 0.312 (0.79) 4X 0.281 X 0.656 OBROUND 2X (0.71 X 1.67) Ø 0.281 (0.71)

5.87 (14.91)

5.00 2.37 (6.02) (12.70)

2.93 (7.44) 7.00 (17.78) 9.87 (25.07)

Optional blanket heater available to allow operation to -50°F (-45°C). Over twenty years of quality design and manufacturing have resulted in pan/tilts which provide long, reliable operation.

10.87 (27.61)

11.25 (28.58)

Ø6.00 (15.24) Ø 0.390 X 0.80 (0.99 X 2.03) SLOT 4X EQ SP ON A Ø4.75 (12.06) B.C.

NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.

C330 / REVISED 10-03

International Standards Organization Registered Firm; ISO 9001 Quality System

Page 2 of Pelco PT570 Spec Sheet

The text of page 2, from the PDF itself

2005 Spec Book.book Page 246 Wednesday, March 9, 2005 8:50 AM

TECHNICAL SPECIFICATIONS MODELS

MECHANICAL

PT570P PT570P/PP PT570-24P PT570-24P/PP

Medium duty pan/tilt, 120 VAC Medium duty pan/tilt with presets, 120 VAC Medium duty pan/tilt, 24 VAC Medium duty pan/tilt with presets, 24 VAC

ELECTRICAL PT570P 120 VAC, 50/60 Hz

Input Voltage Power Requirements (Running)

Pan Tilt Pan Tilt

(Starting) Connectors Motors Limit Switches Conductor Requirements

PT570-24P 24 VAC, 50/60 Hz

0.18A (21.6 VA) 0.9A (21.6 VA) 0.18A (21.6 VA) 0.9A (21.6 VA) 0.27A (32.4 VA) 1.35A (32.4 VA) 0.27A (32.4 VA) 1.35A (32.4 VA) AMP CPC type (mate supplied) Two-phase induction type, instantaneous reversing 5A each (pan and tilt); external adjustment 6 or 7, unshielded (functions: left, right, up, down, motor common, safety ground). (No additional conductors for auto scan when used with solid-state control. PP option requires 4 additional conductors.)

Maximum Operating Distances CONTROL

BRELAY BOXAA

GENERAL Construction Finish Environment Unit Weight Shipping Weight

BHB/570PT570P 6 Conductors

20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2)

1,045 ft 1,665 ft 2,640 ft

7* Conductors

20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2)

2,080 ft (634 m) 3,330 ft (1,015 m) 5,285 ft (1,611 m)

20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2)

40 ft 65 ft 110 ft(12 m) (20 m) (34 m)MPT24DT MPTAZ Series

20 AWG (0.5 mm2) 18 AWG (1.0 mm2) 16 AWG (1.5 mm2) *Using 2 wire motor common

85 ft 135 ft 220 ft(26 m) (41 m) (67 m)RB115, RB24

PT570-24P 6 Conductors 7* Conductors

Heavy-duty ball bearings Oilite bronze bushing Mechanical friction-type 50% duty cycle; 30 minute rating

Aluminum plate; all internal parts corrosion protected Gray polyester powder coat Outdoor; -10° to 120°F (-23° to 49°C) 22 lb (9.9 kg) 25 lb (11.5 kg)

OPTIONS

Maximum Distance Cable Size

Bearings Pan Tilt Braking Duty Cycle

  • CE, Class B (PT570-24P, PT570-24P/PP)
  • UL Listed
  • Meets NEMA Type 3R standards

PAN/TILT 24 VAC CONTROL

Gearing

0-355° movement in horizontal plane 6°/sec ±1° 10 ft-lb with specified voltage ±90° movement in vertical plane 3°/sec ±0.5° 20 ft-lb with specified voltage 40 lb (18.1418.14 kg) at 5" (12.7 cm) from tilt table surface to center of gravity Adjustable worm-gear final drive to prevent drift and minimize backlash

CERTIFICATIONS/RATINGSPAN/TILTA

Pan Speed Torque Tilt Speed Torque Maximum Load

(319 m) 5,800 ft (1,767 m) (507 m) 8,250 ft (2,515 m) (805 m) 13,000 ft (3,962 m)

Notes: 1. Distance (A) from control to pan/tilt is the same as distance from relay box to pan/tilt. 2. Maximum operating distance can be extended by using a low voltage control (24 VAC) and a relay box. Distance (B) from control to relay box is the same for all applications. 3. Distances are calculated with both motors (pan and tilt) running and assuming a 10% voltage drop in the cable.

RECOMMENDED CONTROLS Coaxitron or Matrix

See individual specification sheets for information. Desktop control for 24 VAC pan/tilt. Desktop pan/tilt and zoom lens control with auto/random scan. Relay box for extended low voltage operation. Extends operating distance (control to relay box).

RECOMMENDED ENCLOSURE EH4700 Series

Environmental enclosure

RECOMMENDED MOUNTS PA2000 PM2000, PM2010 ST1 WM2000

Pelco Worldwide Headquarters: 3500 Pelco Way, Clovis, California 93612-5699 USA USA & Canada Tel: (800) 289-9100 • FAX (800) 289-9150 International Tel: (559) 292-1981 • FAX (559) 348-1120 www.pelco.com

Blanket heater in cover, 75W. Allows operation to -50°F (-45°C). 120 VAC, 50/60 Hz.

Adapter plate; required when using WM2000 Ceiling/pedestal mount; maximum load 125 lb (56.7 kg) Support strut; use with WM2000/PM2000/ PM2010 Wall mount; maximum load 75 lb (34 kg)

Pelco and the Pelco logo are registered trademarks of Pelco. Specifications subject to change without notice. ©Copyright 2003, Pelco. All rights reserved.