The text of a spec sheet · part 1 of 1
COMSPHERE 3610 Series DSUs, pages 1 to 6
Pages 1 to 6 of 6
The original document is the PDF (65 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Paradyne Comsphere 3610
Page 1
®
COMSPHERE
3610 SERIES DSUs F E A T U R E S
3610 SERIES •
FULLY INTEGRATED NETWORK MANAGEMENT CAPABILITIES FOR COMPREHENSIVE TESTING, MONITORING AND CONTROL
C
OMSPHERE 3610 Series Data Service Units (DSUs) are highly reliable, state-of-the-art products ideal for today's network-managed digital environments. The COMSPHERE 3610 DSU •
ASCII TERMINAL INTERFACE ALLOWS AN ASCII TERMINAL FULL DIAGNOSTIC AND enables users to take maximum advantage of today’s digital services.
CONFIGURATION CONTROL OF Operating in conjunction with Paradyne's COMSPHERE 6700 Series Network Management STANDALONE VERSIONS ONLY System (NMS), the COMSPHERE 3610 Series DSU provides a comprehensive network •
NETVIEW LPDA-2 MANAGEMENT
•
POINT-TO-POINT AND MULTIPOINT management solution that is both flexible and affordable. Network management options are
NON-DISRUPTIVE DIAGNOSTICS expanded to include SNMP when used with the COMSPHERE 6700 and optional SNMP agent
•
DDS RATES FROM 2.4 TO 64 Kbps software. The series uses an advanced diagnostic technique to provide comprehensive network
•
USER-CONFIGURABLE DATA RATES FROM monitoring, testing and control over point-to-point and multipoint circuits. Network managers are
150 TO 56,000 bps AND 64,000 bps (CLEAR provided with a comprehensive feature set and options that combine to maximize network
CHANNEL) •
RATE ADAPTATION FOR POINT-TO-POINT AND MULTIPOINT CIRCUITS
• availability, reduce equipment costs, and provide fully integrated network management control. The COMSPHERE 3610 also provides an SNA Diagnostic Interface for enhanced NetView LPDA-2
AVAILABLE IN STANDALONE AND CARRIER interoperability. Low-cost device control is provided via an ASCII terminal using the COMSPHERE CARD VERSIONS 3610 ASCII support feature. This feature is available only in the standalone version.
•
CO-RESIDENT EIA-232D/V.24 AND CCITT V.35 INTERFACES (continued on page 2)
™
Page 2
F E A T U R E S 3610 SERIES (continued from page 1)
3610 SERIES SPECIFICATIONS DSU Module Digital data services provided by Regional Bell Operating Companies (RBOCs) and Local Exchange Carriers (LECs)
•
AUTO RATE DETECTION
•
CROSS PAIR DETECTION
•
EXTENDED RANGE SUPPORT
Data Rate Synchronous terminal rates of 2,400, 4,800, 9,600, 19,200, 56,000 and 64,000 bps
•
POINT-TO-POINT OR MULTIPOINT
Elastic Storage Buffer +/- 8 bits
•
OPERATION
Timing DDS, internal, external or receiver
STANDALONE VERSION FEATURES A
Data Format Serial, synchronous, protocol-independent, binary data in full or half-duplex operation
USER-FRIENDLY FRONT PANEL WITH A TWO-LINE, 16-CHARACTER PER LINE, MENU-DRIVEN DISPLAY WITH KEYPAD FOR CONTROL OF LOCAL AND REMOTE DEVICES •
FULL COMPLEMENT OF LOCAL AND REMOTE LOOPBACKS
•
INTEGRAL 511 TEST-PATTERN GENERATOR AND COMPARATOR
•
THREE POWER LEVELS FOR COMPATIBILITY WITH RBOC AND LOCAL EXCHANGE CARRIER FIXED DATA RATES OF 19,200 bps
•
ELASTIC STORE FEATURE FOR EXTENDED CIRCUIT APPLICATIONS
•
Transmit Levels 19,200 bps: -10, 0, or +6 dBm 9,600 bps: 0 dBm All other speeds: +6 dBm Receiver Sensitivity Level -42 dBm at 56,000 bps Transmit and Receive Impedances 135 ohms nominal Digital Network Interface 3610 Standalone: 8-pin modular jack, USOC RJ48S 3611 Carrier Card: 50-pin connector, USOC RJ48T (one for slots 1-8, one for slots 9-16) Network Management System Compatibility COMSPHERE 6700 (6800) Series NMS Device control via ASCII interface (Standalone only)
POINT-TO-POINT OPERATION AS A LIMITED DISTANCE MODEM
•
Data Encoding Bipolar return to zero; complies with AT&T Technical Reference 62310 - 1987
ASYNCHRONOUS OR SYNCHRONOUS
DTE Interface 25-pin subminiature connector (female) EIA-232D/CCITT V.24 (ISO 2110) 34-pin connector (female) CCITT V.35 (ISO 2593)
SUPPORT ON ALL PORTS AC Power Requirements 3610 Standalone: 90-132 VAC, 60 Hz +/-3Hz, 0.15 amp: 13.4 watts max at 115 VAC
Environment Operating temperature: 32° F (0° C) to 122° F (50° C) Storage temperature: -4° F (-20° C) to 158° F (70° C) Relative humidity: 5% to 90% non-condensing Shock and vibration: withstands normal shipping and handling Heat Dissipation at 115 VAC 3610 Standalone 32.4 BTU/hr max 3000 Series Carrier (16 DSUs plus SDU and fan module) 563 BTU/hr max Dimensions 3610 Standalone: Height: 2.13 inches (5.4 cm) Width: 7.63 inches (19.4 cm) Depth: 13.4 inches (34.0 cm) 3611 Carrier Card: Height: 7.13 inches (18.1 cm) Width: 0.9 inches (2.3 cm) Depth: 13.4 inches (34.0 cm) 3000 Series Carrier: Height: 10.5 inches (26.7 cm) Width: 19.0 inches (48.3 cm) Depth: 14.0 inches (35.6 cm) Weight 3610 Standalone: 5 lb. (2.3Kg) 3611 Carrier Card: 1.5 lb (0.7Kg) 3000 Series Carrier: (16 DSUs plus SDU and fan): 70 lbs. (31.8 Kg) Regulatory Approvals FCC Part 15 - Class A digital device FCC Part 68 - AW292J-61661-DD-N 3610 Standalone: Listed UL 1950 Certified CSA C22.2, No. 220-M1986 3611 Carrier Card, 3000 Series Carrier: Recognized Component UL 1950 CSA Safety - Certified CSA 22.2 No. 950-M89 3610 and 3611: CSA Emissions - Class A digital apparatus Bell Canada - "DCTE Specifications," July 1989, Issue 1
3611 Carrier Card: Supplied by carrier: 80 watts max 3000 Series Carrier fan module: Supplied by carrier: 45 watts
2
™
Page 3
O P T I O N A L TDM/MCMP •
MULTICHANNEL MULTIPOINT (MCMP)
F E A T U R E S
TIME DIVISION MULTIPLEXER (TDM)/MULTICHANNEL MULTIPOINT (MCMP) OPTION Increased flexibility in network design and implementation is an important advantage of the Time
FUNCTION THAT ALLOWS UP TO SIX Division Multiplexer/Digital Sharing Device (TDM/DSD 'Flex') option, while providing cost-effective NON-DISRUPTIVE, PROTOCOL INDEPENDENT DATA PATHS OVER A SINGLE MULTIPOINT CIRCUIT data networking alternatives. The TDM/DSD 'Flex' function improves the use of digital facilities through bandwidth control and allocation. The TDM/DSD 'Flex' option can be controlled by the 6700 Series NMS, the Shared Diagnostic Control Panel (SDCP), or the COMSPHERE 3610 front panel.
•
STANDALONE ONLY VERSION HAS 'FLEX' MUX FUNCTION--2 OR 6 PORTS: 1 OR 5 PORTS (DB25) IN THE EXPANDED as a DSD, the DSU allows up to six polled-protocol devices to share a single point-to-point or multi-
ELECTRICAL EIA-232 OR V.35, AND 1 PORT point digital facility. Configured as a host port-sharing device, the TDM/DSD 'Flex' shares up to six
V.35 CONNECTOR OPERATIONAL MODES OF MCMP, TDM, DSD AND MULTIPOINT DIAL RESTORAL BRIDGE •
The TDM will multiplex up to six channels onto a single point-to-point digital facility. Configured
HOUSING CONFIGURED AS EITHER
ON THE BASE DSU AS EITHER EIA-232D OR
•
TDM
ONE- OR TWO-PORT SHARING GROUPS host ports for the primary purpose of disaster recovery. Three ports are used for the primary data path and three ports for automatic 'hot' spare during a front end port failure. The versatile TDM/DSD 'Flex' option when configured with the Dial Backup Module (DBM) card version, serves as the digital bridge for multipoint single-call dial restoral applications.The TDM/DSD 'Flex' option requires an expanded housing to the COMSPHERE 3610 standalone version and a separate card slot in the COMSPHERE 3000 Series Carrier with the COMSPHERE 3611 card version.
THAT PROVIDE UP TO 6 PORTS MCMP •
AUTOMATIC TDM RECONFIGURATION TO A REDUCED DATA RATE UPON ENTRY INTO DIAL RESTORAL MODE
•
•
•
TDM/DSD functions while adding MCMP functions to create one of the most powerful and flexible DSUs in the industry. The sophisticated MCMP option uses a patented technology to consolidate
INDIVIDUAL PORT TESTS AND multiple applications and protocols over a single multipoint digital facility. Up to six individual data
LOOPBACKS channels can be configured for your multipoint circuit. Each channel is non-interfering with other
ELASTIC STORE FEATURE PROVIDES channels and protocol insensitive. These characteristics broaden the number of applications available
A BUFFER ON EACH PORT TO SUPPORT to allow both point-to-point and multipoint applications to work on the same mulitpoint circuit.
DIGITAL OR ANALOG EXTENDED CIRCUITS •
The MultiChannel MultiPoint (MCMP) option builds on TDM/DSD features by supporting all
MCMP comes in both a two- and six-port standalone version that can be mixed on the same
DIGITAL BRIDGE FOR MULTIPOINT DIAL circuit. This means you do not have to buy a six-port version for all remote sites (when all you need
RESTORAL is a two-port version at some sites and a six-port version at other sites). The unique any port to any
CONCURRENT OPERATION OF TDM AND DSD MODES port mapping feature from the central site DSU to remote DSUs, adds flexibility to your configuration choices. This unique mapping feature allows remote site configurations to support both MCMP and DSD applications. As with the TDM/DSD option, up to two DSD groups can be configured or use the digital bridge mode for multipoint single-call dial restoral applications. (continued on page 4)
3
™
Page 4
MCMP (continued from page 3) The TDM/MCMP option is supported by both the COMSPHERE 3610 standalone version and the COMSPHERE 3611 card version. The standalone version provides 'Flex' function which allows each port to be configured as either RS232 or V.35 electrical. An expanded housing which provides either one or five standard (DB25) connectors is required for either two- or six-port TDM/MCMP respectively. When V.35 electrical is selected, a DB25 to V.35 conversion cable is required for ports two through six. No conversion cable is required for port one because it is assigned to either an RS232D or V.35 connector on the base DSU unit. The card version supports two- or six-port TDM/MCMP with port one as either RS232D or V.35 connector and ports two through six as RS232. A DB26 to V.35 connector cable is required when port one is assigned as a V.35 connection. Two-card slots are required to support TDM/MCMP in the COMSPHERE 3000 Series Carrier. Thus, allowing a maximum of eight MCMP DSUs per carrier.
Asynchronous Character Format 6, 7, 8, 9, or 10 bits; 1 or 2 stop bits
TDM/MCMP SPECIFICATIONS Composite Speeds TDM: 2,400; 4,800; 9,600; 19,200; 38,400; 56,000; and 64,000 bps
Elastic Storage Buffers +/- 5 bits per second
MCMP: 56,000 bps (48,000 usable for data)
Timing DDS, internal (all ports), external (provided by selected port)
Port Speeds Synchronous terminal rates of: 1,200; 2,000; 2,400; 4,000; 7,200; 8,400; 9,600; 12,000; 14,400; 16,800; 18,000; 19,200; 28,800; 32,000; 38,400; 48,000; 56,000; and 64,000 bps (1,200 bps synchronous not supported at 56,000 bps and 64,000 bps composite line rate)
Digital Sharing Device (DSD) Two groups up to six ports Contention: RTS or ungoverned
DIAL BACKUP MODULE SPECIFICATIONS ISDN BRI Module
V.32bis Module
Application Full-duplex data transmission via ISDN BRI U-Interface for point-to-point or multipoint facilities. Integrated NT1 included.
Analog Dial Module Full or half-duplex data transmission via analog 2-wire DDD Communications Line 2-wire PSTN line
Modulation and Frequency 2B1Q line coding with 4-level pulse amplitude modulation (PAM) at 80K baud
Data Rate Synchronous or asynchronous terminal rates of 2,400, 4,800, 9,600, 12,000 and 14,400 bps
Channel Equalization Receiver: Automatic adaptive equalizer with echo cancellation
PSTN Network Interface 3610 Standalone: 8-pin modular jack Permissive: USOC RJ11C Programmable: USOC RJ45S 3611 Carrier Card: 50-pin connector (one for slots 1-8, one for slots 9-16) Permissive: USOC RJ21X Programmable: USOC RJ27X
Communication Line 2-wire BRI ISDN line Data Rates 56 and 64 Kbps (Note that ISDN DBM or DBM-I use proprietary rate adaption to support data rates of less than 64 Kbps.) DBM Interface Compatible with 3600 Series 2-wire and 4-wire Switched 56 DBMs
SW56 Modules
Receive Interface Dynamic Range: Operates on 2-wire loops as defined an ANSI T1.601-1992 Impedance: 135 Ohms
Digital Dial Module (DM) Full or half-duplex data transmission via: 4-wire Switched 56 Kbps or 2-wire Switched 56 Kbps, point-to-point Communications Line 4-wire Switched 56 Kbps (AT&T ACCUNET, AT&T SDDN, and U. S. Sprint VPN56) 2-wire Switched 56 Kbps (DataPath Compatible)
Switched Network Interface 3610 DSU: 8-pin non-keyed modular jack, USOC SJA11 U-Interface Connector 3611 DSU: (One or two) 50-pin connector, pinout same as RJ21X
Data Rate Synchronous or asynchronous terminal rate of 56,000 bps
Transmit Interface Signal Level : 13.5 dBm nominal over frequency band from 0 Hz to 80K Hz Impedance: 135 Ohms
4-Wire Switched 56 Kbps Network Interface 3610 Standalone: 8-pin modular jack USOC SJA56 3611 Carrier Card: 50-pin connector, USOC SJA57 (one for slots 1-8, one for slots 9-16) 2-Wire Switched 56 Kbps Network Interface 3610 Standalone: SJA48 6-pin modular jack 3611 Carrier Card: 50-pin connector (Pinout same as RJ21X)
4
™
Page 5
O P T I O N A L
F E A T U R E S
3610 back panel 3610 with TDM back panel
DIAL BACKUP MODULE
DIAL BACKUP MODULE (DBM) OPTIONS
•
WIDE SELECTION OF AUTOMATIC DIAL
The Dial Restoral option offers complete flexibility in all areas of user application recovery. Dial
RESTORAL OPTIONS WITH ISDN BRI
Restoral provides automated, single-call, point-to-point and multipoint restoral over either the ISDN BRI
(1B+D), ANALOG V.32bis (14.4 Kbps) OR 2- OR 4-WIRE SW56 network, the two-wire Public Switched Telephone Network (PSTN), two-wire Switched 56 Digital Network, or four-wire Switched 56 Digital Network.
•
TO ENSURE AVAILABILITY OF RESTORAL
Point-to-point restoral is accomplished using an integral Dial Backup Module (DBM). Dial line rates
CIRCUIT supported for the ISDN BRI connection include full duplex, 56,000 or 64,000 bps operation. Dial line rates supported for the PSTN connection include full duplex, 14,400 bps, 12,000 bps, 9,600 bps, 4,800 bps, or 2,400 bps operation.
UNIQUE “DIAL TONE” MONITORING
•
AUTOMATIC RETURN TO DIGITAL LEASED LINE AFTER RESUMING NORMAL SERVICE
The dial restoral connection can be controlled by the COMSPHERE 6700 Series NMS, the Shared Diagnostic Control Panel (SDCP), or the COMSPHERE 3610 front panel. While in dial restoral mode, the DSU automatically looks back to the digital facility and evaluates its health, switching back as soon as service is restored. This automatic "lookback" feature helps minimize line costs by eliminating extended long-distance line charges once the digital facility becomes operational again. Networks requiring continuous availability can now attain uptime goals without dedicated around-the-clock staffing at the network control center. An automated dial tone test during non-usage periods informs network operations if the dial restoral circuit is disconnected. This eliminates the requirement for expensive and time-consuming manual testing of dial restoral circuits by network operations. In addition to its automatic restoral capabilities, the versatile Dial Restoral Option features password and call-back security. When enabled, these security options prevent unauthorized access and ensure integrity of the digital facility. A 10-number directory is capable of selecting alternative destinations for the automated dial restoral process, as well as call-back numbers for security. Multipoint dial restoral is easy using the digital bridge feature of the card version TDM/MCMP option and the DBMs, both of which are housed in the COMSPHERE 3000 Series Carrier. Each digital bridge provides bridging for five remotes. Additional bridges can be interconnected to the first or primary bridge, up to a maximum of six (including the primary bridge), to back-up a total of 25 remotes. The COMSPHERE 6700 Series NMS maintains complete control of the network during the multipoint restoral process.
5
™
Page 6
CONTROLS AND INDICATORS The COMSPHERE 3610 Diagnostic Control Panel (DCP), 3611 face plate, and the optional SDCP feature a full complement of controls and indicators. They incorporate a menu-driven, Englishlanguage display to monitor on-line performance, change operating modes, and control local and remote testing. Indicators These display signal activity at the DTE/DSU interface and provide operational status information. Alpha-Numeric Display The two-line by 16-character LCD on the front panel displays status information and serves as the primary user interface for equipment setup, reconfiguration, and diagnostic operation.
Controls Function keys (F1, F2, etc.) are used to select options and move within the menu structure for equipment configuration, testing and similar operations. Basic DSU Indicators TXD/103 - Transmit data RXD/104 - Receive data RTS/105 - Request-to-send CTS/106 - Clear-to-send DSR/107 - Data set ready DTR/108 - Data terminal ready LSD/109 - Line signal detect
Test - Test in progress Dial - DBM active Front Panel - Indicates card selected by SDCP (3611 only) SDCP- Controls and Indicators Select - Provides SDCP selection of carrier DSU Bck Up - Indicates selected DSU in dial backup mode DCP Controls – Moves up one menu level – Moves one position to left on menu – Moves to top of menu
DSU Status Indicators OK - Normal operation Alarm - Fault in DSU, DBM or facility; streaming DTE
– Moves one position to right on menu F1, F2, F3 - Multifunction keys defined by display line located above them
ORDERING INFORMATION Description
Model Number
Description
Model Number
Description
Model Number
Standalone DSU
3610-A4-001
Field upgrade options to existing DSUs
Field upgrade options to existing DSUs
Nest DSU
3611-B4-001
S/A DSU upgrade to 2 port TDM/MCMP 'Flex' Field Install
3600-F3-209
ISDN BRI Dial Restoral Field Install
3600-F3-026 3600-F3-201
S/A DSU upgrade to 6 port TDM/MCMP 'Flex' Field Install
3600-F3-213
14.4 Kbps analog Dial Restoral Field Install 4W-SW56 Dial Restoral Field Install
3600-F3-056
NEST DSU upgrade to 6 port TDM/MCMP Field Install
3600-F4-205
2W-SW56 Dial Restoral Field Install
3600-F3-256
3600-F3-500
Network Interface Module (NIM) for use with COMSPHERE 3000 Carrier and 3611 card version DSU:
COMSPHERE 3000 Carrier with 115 VAC Power
3000-B1-201
COMSPHERE 3000 Carrier Options: Fan Module (115 VAC)
3000-F1-007
Shared Diagnostic Control Panel (with ribbon cable)
3000-F1-001
Cables
Shared Diagnostic Unit (SDU)
3000-F1-002
V.35 Interconnect Cable for card version only (18")
Rear Connector Plate
3000-F1-021
DSUs with integrated dial restoral modules:
Filler Panel
3000-F1-008
S/A R3 DSU w/ ISDN BRI DBU
3610-A4-026
NMS EIA-232 Interface Connector
6821-F1-513
Permissive for ISDN BRI, 14.4 Kbps and 2-wire SW56 Kbps (1 per 8 carrier slots)
3000-F1-003
Programmable for 14.4 Kbps (1 per 8 carrier slots)
3000-F1-004
For 4-wire SW56 Kbps (1 per 8 carrier slots)
3000-F1-025
Nest R3 DSU w/ISDN BRI DBU
3611-B4-026
Remote-site Adapter Cables 6821-F1-518 (M6AYand M6BK - 7' and 5' respectively)
S/A R3 DSU w/14.4 Kbps analog DBU
3610-A4-002
Network Adapter Cable
Nest R3 DSU w/14.4 Kbps analog DBU
3611-B4-002
Standalone R3 DSU w/4W-SW56 DBU
3610-A4-014
50-pin mass termination cable (1 per NIM) Permissive RJ21X
Nest R3 DSU w/4W-SW56 DBU
3611-B4-014
Programmable RJ27X Telephone Cables for use with Standalone COMSPHERE 3610 Series DSU
Standalone R3 DSU w/2W-SW56 DBU
3610-A4-012
Nest R3 DSU w/2W-SW56 DBU
3611-B4-012
1.5' 3600-F2-503
50-pin to eight 8-pin Modular Network Interfaces (DSU/JM8 lease) Adapter for Digital or Leased Lines
3600-F2-503
ASCII Interface Cable (DSU Control Channel RJ11 to DB25 DTE connector)
10' 3600-F3-504
10' - 3000 F1-013 30' - 3000-F1-014
3610 Series DSU Modular RJ11C (6-pin) Permissive DDD (PSTN) plug
7' - 4400-F1-531 14' - 3600-F3-503 25' - 4400-F1-533
Modular RJ45S (8-pin) Programmable DDD (PSTN) plug
7' - 4400-F1-541 14' - 4400-F1-543 25' - 4400-F1-544
S/A DSU with 2 port TDM/MCMP ‘Flex’
3610-A4-020
S/A DSU with 6 port TDM/MCMP ‘Flex’
3610-A4-024
Card version dial restoral modules for multipoint circuits for use with TDM card version optioned as digital bridge:
Nest DSU with 6 port TDM/MCMP
3611-B4-003
ISDN BRI DBM-I M/P Dial Restoral
3611-B4-016
V.35 Interconnect Cable for card version only
3600-F3-500
14.4 Kbps analog DBM-V M/P Dial Restoral
3611-B4-005
Modular RJ11C (6-pin) (for 2-wire SW56 Kbps)
14' - 3600-F3-503
4W-SW56 DBM-S M/P Dial Restoral
3611-B4-008
2W-SW56 DBM-D M/P Dial Restoral
3611-B4-010
Modular RJ45S (8-pin) (for 4-wire SW56 Kbps)
14' - 3600-F3-501 25' - 3600-F3-502
Telephone Cords for use with Standalone COMSPHERE 3610 Series DSU
For additional information on this or any Paradyne product or service, contact the office nearest you. Or, dial toll-free (USA) 800 PARADYNE or call 813 530-8623. Fax (USA) 813 530-8216. Toronto 905 709-5000 fax: 905 709-3469 Hong Kong 852 2543-0083 fax: 852 2541-3767 Singapore 65 355-5230 fax: 65 355-5244 France 33 492 942-500 fax: 33 492 942-501 China 8610 6499-1425 fax: 8610 6492-5915
Montreal 514 288-0001 fax: 514 288-1246 Japan 81 3-5541-6630 fax: 81 3-5541-6631 Latin America 813 530-8358 fax: 813 532-5240 Visit the Paradyne Power Pages at http://www.paradyne.com Japanese Language website: www.paradyne.co.jp
Specifications subject to change without notice. Printed in U.S.A. ©Paradyne Corporation 1998.
DIG-DS36-3-0398
COMSPHERE is a registered trademark of Paradyne Corporation. PARADYNE and ANALYSIS are trademarks of Paradyne Corporation. All other products or services mentioned are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.
6
™