Page 1

ValuScan VS6500 Rev. 6.07

C measuring light curtains

■

ValuScan VS6500

Single-Axis High-Speed Optical Profiling Scanners Single axis versions (for dual axis versions refer to the VXY6500)

■

Wide variety of beam spacings and resolutions available

■

■

Wide variety of outputs:, Serial data, TTL parallel, Relay, Analog, Optional cards enhance flexibility of outputs

Two operating ranges

■

High immunity to all types of ambient light

■

DoubleScan mode for enhanced resolution

■

US

Description

A complete ValuScan system consists of a transmitter, receiver, controller, and interconnecting cables. The transmitters and receivers provide a wide choice of beam spacings, object resolutions, and ranges. Two different controllers provide many output and measurement options for use with almost any system. The transmitter is a linear array of light emitting diodes (LEDs). The receiver is a linear array of phototransistors. Each LED and its corresponding phototransistor create a beam. The controller turns on each beam in succession. As each LED is turned on, the corresponding phototransistor is examined to determine if an object is blocking the beam. After scanning through the array, the controller updates the various outputs based on the status of the beams. To operate the scanner you first set the scanner’s operating parameters. This is done using Omron STI’s MS-DOS® or Windows® 95/98 based setup software or using an ASCII terminal emulator. These parameters control how the scanner operates, which outputs are used, and what information is reported. During setup, these parameters are saved in non-volatile memory. During operation, the scanner operates without external control, or it can be set for external control through a hardware or software trigger.

MS-DOS® and Windows® are registered trademarks of Microsoft Corporation.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca

Page 2

ValuScan VS6500

■

Applications

Hole Detection Holes can be detected in almost any opaque material.

measuring light curtains

Slack Loop Control Omron STI scanners can determine the level of slack loops. ValuScan operates best when scanning opaque materials. Belt or Sheet

Too Tight Correct Too Loose Speed Control Transmitter

Receiver

Receiver

Transmitter

Product Profiling The height, width or shape of an object can easily be measured using a single axis scanner. ValuScan systems can perform this function directly.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca

Page 3

ValuScan VS6500 measuring light curtains

■

Special Features

ValuScan scanners incorporate several special functions to enhance their versatility. These are built into the operating firmware and can be activated through the setup commands.

Double Scan This allows you to improve resolution in some applications by interpolating between the beams.

Screen Mode Screen Mode allows you to ignore objects under a specific size.

Masking Masking allows you to manipulate the reported status of each beam (for example, inverting the status of the beams to detect holes rather than objects).

Zone Functions This allows you to define up to 8 zones within any scanner. An independent TTL or optional relay output for each zone indicates when an object is detected within the zone.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca

Page 4

ValuScan VS6500

■

Specifications

Optical Performance Minimum Detectable Object* Beam Spacing Normal Scan

Scan Length

DoubleScan Minimum Increment Maximum Range

0.32 in. (8.2 mm)

0.22 in. (5.7 mm)

4.7 in. (120 mm)

4.7 in. (120 mm)

47.2 in. (1200 mm)

16 ft. (4.9 m)

0.45 in. (11.4 mm)

0.33 in. (8.3 mm)

6 in. (152 mm)

6 in. (152 mm)

96 in. (2438 mm)

16 ft. (4.9 m)

0.39 in. (10 mm)

0.59 in. (15.1 mm)

0.40 in. (10.1 mm)

12.6 in. (320 mm)

12.6 in. (320 mm)

37.8 in. (960 mm)

16 ft. (4.9 m)

0.50 in. (12.7 mm)

1.00 in. (25.4 mm)

0.75 in. (19.1 mm)

24 in. (610 mm)

12 in. (305 mm)

72 in. (1829 mm)

80 ft. (24 m)

0.75 in. (19.1 mm)

1.25 in. (31.8 mm)

0.88 in. (22.2 mm)

24 in. (610 mm)

12 in. (305 mm)

72 in. (1829 mm)

80 ft. (24 m)

* Minimum detectable object shown is for non-moving objects measured in a direction parallel to the long axis of the scanner.

Scan Rate: 50 microseconds per beam plus 200 microseconds. (For M5, 0.25, and

Series C & D Controllers:

M10 series, faster scan time may be used with reduced range and short

115 VAC ±10% 50/60 Hz 30 VA maximum power consumption cables.) Note: Scan time is exclusive of serial data communication time.

230 VAC ±10% 50/60 Hz 30 VA maximum power consumption

Serial Communications:

24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power

RS-232 or RS-422 protocol (user selected)

consumption

9,600, 19,200 or 38,400 Baud Rate

Field conversion of operating voltage between 115 VAC and 230 VAC

Parallel Output: (Series A & B Controllers only) 8 bit TTL compatible; 0 to +5 VDC transition; sources or sinks 10 mA. Connection is through male ribbon cable header can be accomplished. Conversion from AC to DC or DC to AC cannot be accomplished. Cable: 98.4 ft. (30 m) maximum Cable diameter is 0.30 in. (7.6 mm).

Relay Output: SPDT Reed Relay; Maximum switching capacity: 25 VDC at 100 mA Do not switch AC loads with this relay. Hardware Trigger: (Series A & B Controllers Only) Optically isolated input. Signal transition between 0 and +5 VDC at 10 mA is required. Maximum current allowed is 20 mA. Positive signal is active. Use a resistor to limit current. Environmental Rating:

Cable connector diameter is 1.35 in. (34.3 mm) Mechanical Endurance: Vibration: 0 to 100 Hz Acceleration: 98 m/s2, 10 G Shock: 4.1 Joules, 3 ft.-lb. Agency Approvals: CSA-CUS, CE Optional Output Cards: (Series A & B Controllers Only)

Temperature Rating: 32 to 131°F (0 to 55°C)

AIC-02 Analog Output: 0 to +10 VDC, -10 to +10 VDC, or 4 to 20 mA

Transmitters and Receivers: NEMA 12, IP65 current sinking (user selectable)

Enclosed controllers: NEMA 12, IP65

ARC-02 Analog Relay Card: 4 SPDT Reed Relays; Maximum switching

Power Requirements:

capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays.

Series A Controllers:

Hysteresis: In beams, multiply 0.016312 times the number of beams

115 VAC ±10% 50/60 Hz 30 VA maximum power consumption and round up to the nearest whole number. For example, 120 beams

230 VAC ±10% 50/60 Hz 30 VA maximum power consumption gives 1.95, which rounds up to 2 beams. It will require clearing at least

24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power

2 beams before the relay will release after it has been energized.

consumption

PRC-02 Parallel Relay Card: 4 SPDT Reed Relays; Maximum switching

Series B Controllers:

capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays.

24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power

PRC-08 Parallel Relay Card: 8 SPDT Reed Relays; Maximum switching consumption capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays. PCC-02 Parallel Connection Card: Provides screw terminal connections instead of ribbon cable header for 8-bit parallel output. Specifications are subject to change without notice.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca measuring light curtains

0.20 in. (5 mm) 0.25 in. (6.4 mm)

Page 5

ValuScan VS6500 measuring light curtains

■

Controller Specifications

Two controller styles are available: 1) a serial controller that provides serial data and a relay output, and 2) a VSU controller that provides serial, parallel, relay, and optional analog outputs. Each controller can operate any of the transmitters and receivers. Each controller is available with or without a metal enclosure.

■

Serial Controller: Series C and D

The serial controller is a simple controller designed primarily for OEM applications. It provides serial data and relay outputs only, and is an integrated power supply/controller assembly. It is available as a Series C controller in a compact metal enclosure (rated NEMA 12, IP65) or as a Series D controller printed circuit board assembly without an enclosure. Both series are available for operation on 115 VAC, 230 VAC, or 24 VDC. The serial output can be set to give any of the information shown in the chart below. Serial Controller Dimensions, in./mm 1.69 min. (42.9)

7.40 (188.0)

0.30 Dia mtg holes (8) (7.6) 4.00 (101.6)

r

VS Controller

9.60 (243.8)

10.10 (256.5)

10.80 (274.3)

2.81 (71.4)

6.55 (166.4) SiDe VieW frOnt VieW

2.05 (52.1) BAcK VieW

Standard Outputs Serial Data: RS-232 or RS-422 protocol. Relay Output: SPDT Reed Relay. The relay output can be set to energize when any object is detected or when a minimum number of objects is detected. A special hysteresis function lets you set turn-on and turn-off sizes, allowing the scanner to ignore small objects while detecting larger ones.

Serial Controller Output Information Output Options

✔

Highest beam blocked

✔

Size of an object

✔

Size and location of an object

✔

Position of the center of an object

✔

Total number of beams blocked

✔

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

Serial Data Output

Status of each beam (blocked or clear)

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca

Page 6

ValuScan VS6500

■

VSU Controller: Series A and B

VSU Controller Dimensions, in./mm 7.55 191.8

VS controller

AIC-02 Analog Isolator Card gives an analog

0.30 Dia mtg holes (8) 7.6 4.00 101.6

9.55 242.6 output of 0 to +10 VDC, -10 to +10 VDC, or 4 to 20 mA (current sinking). ARC-02 Analog Relay Card provides four SPDT relays driven by the analog output. Each relay

12.0 305 min has a potentiometer to set its trip point and an 10.80 274.3

10.05 255.3

11.16 284

LED to indicate when the relay is energized. This allows for a stand-alone system to perform simple sorting based on the size or position of an object. PRC-02 Parallel Relay Card provides four

6.55 166.4

4.33 110.0

2.05 52.1 frOnt VieW

SiDe VieW

BAcK VieW

SPDT relays that are switched by four of the TTL parallel outputs. PRC-08 Parallel Relay Card provides eight SPDT relays that are switched by the eight TTL parallel outputs.

Standard Outputs

PCC-02 Parallel Connection Card provides

Serial Data: RS-232 or RS-422 Protocol.

screw terminal connections for the TTL solid

Parallel Output: 8 Bit TTL.

state parallel output.

Relay Output: SPDT reed relay. The relay output can be set to energize when any object is detected or when a minimum number of objects is detected. A special hysteresis function lets you set turn-on and turn-off sizes, allowing the scanner to ignore small objects while detecting larger ones.

VSU Controller Output Information The following chart shows what information is available from each of the outputs. Note that each output can be set for only one function. Output Information Options

Serial Data TTL Parallel Output

Status of each beam (blocked or clear)

✔

Analog

Output*

Output (Optional)

Highest beam blocked

✔

✔

✔

Size of an object

✔

✔

✔

Size and location of an object

✔

Position of the center of an object

✔

✔

✔

Total number of beams blocked

✔

✔

✔

*TTL output has 8 bits and is limited to a maximum of 255 beams.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca measuring light curtains

The VSU controller offers the greatest flexibility and widest range of output options for operating this class of scanner. Series A controllers include a NEMA 12 (IP65) rated metal enclosure and operate on 24 VDC, 115 VAC or 230 VAC. The Series B controller is a single printed circuit board assembly operating on 24 VDC.

Optional Outputs A number of optional output cards are available for use with the VSU controller. All VSU controllers allow one of these cards to be mounted directly on the controller printed circuit board assembly.

Page 7

ValuScan VS6500 measuring light curtains

■

Transmitters & Receivers

The following transmitters and receivers can be used with the serial or VSU controllers. Note: the transmitter and receiver must be of the same series and size. ValuScan - M5 Series The ValuScan M5 Series provides a beam spacing of 0.2 in. (5 mm) resulting in the finest resolution in this class of products. It offers a maximum range of 16 ft. (4.9 m) and is available in sizes of 4.7 to 47.2 in. in 4.7 in. increments (120 to 1200 mm in 120 mm increments). ValuScan - 0.25 Series The ValuScan has a beam spacing of 0.25 in. (6.4 mm). It provides fine resolution at a maximum range of 16 ft. (4.9 m). ValuScan 0.25 Series systems are available in sizes of 6 to 96 in. in 6 in. increments (152 to 2438 mm in 152 mm increments). Choose the 0.25 Series for fine resolution at short to medium range. ValuScan M10 Series The ValuScan M10 transmitters and receivers provide a low cost, medium resolution scanner. They are available with 0.39 in. (10 mm) beam spacing in 12.6, 25.2, and 37.8 in. sizes (320, 640, and 960 mm). The operating range of the M10 Series is 16 ft. (4.9 m) maximum. Choose the M10 Series when low cost is more important than fine resolution.

ValuScan Long Range: 0.50 Series and 0.75 Series These long range ValuScan products are high powered profiling scanners. They are available with 0.5 and 0.75 in. (12.7 and 19.1 mm) beam spacings in 2, 3, 4, 5, and 6 ft. (610, 914, 1219, 1524, and 1829 minimum Object Size Parallel to Scanner mm) sizes. The operating range is 80 ft. (24 m). Choose the ValuScan long range scanners when the highest optical power minimum Object is needed. Size Perpendicular to Scanner

Range and Minimum Detectable Object The maximum range (distance between the transmitter and receiver) and minimum detectable object size vary with the ValuScan series. See the chart below for specific information. US Dimensions Minimum Detectable Object* Orientation* Beam

Operating

Perpendicular

Parallel

Series

Spacing Range Normal or DoubleScan Normal Scan DoubleScan

M5

0.2 in.

16 ft.

0.33 in.

0.32 in.

0.22 in.

0.25

0.25 in.

16 ft.

0.20 in.

0.45 in.

0.33 in.

M10

0.39 in.

16 ft.

0.20 in.

0.59 in.

0.40 in.

0.50

0.50 in.

80 ft.

0.5 in.

1.00 in.

0.75 in.

0.75

0.75 in.

80 ft.

0.5 in.

1.25 in.

0.88 in.

Metric Dimensions Minimum Detectable Object* Orientation* Beam Series

Operating

Perpendicular

Parallel

Spacing Range Normal or DoubleScan Normal Scan DoubleScan

M5

5 mm

4.9 m

8.3 mm

8.2 mm

5.7 mm

0.25

6.4 mm

4.9 m

5.1 mm

11.4 mm

8.3 mm

M10

10 mm

4.9 m

5.1 mm

15.1 mm

10.1 mm

0.50

12.7 mm

24 m

12.7 mm

25.4 mm

19.1 mm

0.75

19.1 mm

24 m

12.7 mm

31.8 mm

22.2 mm

* Minimum detectable objects shown are typical values for static (non-moving) objects. Actual values will vary with individual applications. See drawing above for orientation. For moving objects this size must be increased by the scan time multiplied by the speed of the object in the direction of motion. DoubleScan minimum detectable object sizes are determined at the mid-point between the transmitter and receiver.

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca

Page 8

ValuScan VS6500

Available Types of Transmitters & Receivers Scan Length Number of Beams

Scan Length Number of Beams

US Metric Normal Scan Double Scan

US Metric Normal Scan Double Scan

M5

4.7 in.

120 mm

24

48

M10

12.6 in.

320 mm

32

64

M5

9.4 in.

240 mm

48

96

M10

25.2 in.

640 mm

64

128

M5

14.2 in.

360 mm

72

144

M10

37.8 in.

960 mm

96

192

M10

50.4 in.

1280 mm

128

256

M5

18.9 in.

480 mm

96

192

M5

23.6 in.

600 mm

120

240

M5

28.3 in.

720 mm

144

288

M5

33.1 in.

840 mm

168

336

0.50

24 in.

610 mm

48

96

36 in.

914 mm

72

144

M5

37.8 in.

960 mm

192

384

0.50

M5

42.5 in.

1080 mm

216

432

0.50

48 in.

1219 mm

96

192

M5

47.2 in.

1200 mm

240

480

0.50

60 in.

1524 mm

120

240

0.50

72 in.

1829 mm

144

288

64

0.25

6 in.

152 mm

24

48

0.25

12 in.

305 mm

48

96

0.75

24 in.

610 mm

32

144

0.75

36 in.

914 mm

48

96

48 in.

1219 mm

64

128

0.25

18 in.

457 mm

72

0.25

24 in.

610 mm

96

192

0.75

0.25

30 in.

762 mm

120

240

0.75

60 in.

1524 mm

80

160

0.25

36 in.

914 mm

144

288

0.75

72 in.

1829 mm

96

192

0.25

42 in.

1067 mm

168

336

0.25

48 in.

1219 mm

192

384

0.25

54 in.

1372 mm

216

432

0.25

60 in.

1524 mm

240

480

0.25

66 in.

1676 mm

264

528

0.25

72 in.

1829 mm

288

576

0.25

78 in.

1981 mm

312

624

0.25

84 in.

2134 mm

336

672

0.25

90 in.

2286 mm

360

720

0.25

96 in.

2438 mm

384

768

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 measuring light curtains

Series

Series

For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca