The text of a spec sheet · part 1 of 2
ValuScan VS6500 Single-Axis High-Speed Optical Profiling Scanners, pages 1 to 8
Pages 1 to 8 of 15
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Omron V6500 Receiver and Omron V6500 Transmitter
Page 1
ValuScan VS6500 Rev. 6.07
C measuring light curtains
■
ValuScan VS6500
Single-Axis High-Speed Optical Profiling Scanners Single axis versions (for dual axis versions refer to the VXY6500)
■
Wide variety of beam spacings and resolutions available
■
■
Wide variety of outputs:, Serial data, TTL parallel, Relay, Analog, Optional cards enhance flexibility of outputs
Two operating ranges
■
High immunity to all types of ambient light
■
DoubleScan mode for enhanced resolution
■
US
Description
A complete ValuScan system consists of a transmitter, receiver, controller, and interconnecting cables. The transmitters and receivers provide a wide choice of beam spacings, object resolutions, and ranges. Two different controllers provide many output and measurement options for use with almost any system. The transmitter is a linear array of light emitting diodes (LEDs). The receiver is a linear array of phototransistors. Each LED and its corresponding phototransistor create a beam. The controller turns on each beam in succession. As each LED is turned on, the corresponding phototransistor is examined to determine if an object is blocking the beam. After scanning through the array, the controller updates the various outputs based on the status of the beams. To operate the scanner you first set the scanner’s operating parameters. This is done using Omron STI’s MS-DOS® or Windows® 95/98 based setup software or using an ASCII terminal emulator. These parameters control how the scanner operates, which outputs are used, and what information is reported. During setup, these parameters are saved in non-volatile memory. During operation, the scanner operates without external control, or it can be set for external control through a hardware or software trigger.
MS-DOS® and Windows® are registered trademarks of Microsoft Corporation.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca
Page 2
ValuScan VS6500
■
Applications
Hole Detection Holes can be detected in almost any opaque material.
measuring light curtains
Slack Loop Control Omron STI scanners can determine the level of slack loops. ValuScan operates best when scanning opaque materials. Belt or Sheet
Too Tight Correct Too Loose Speed Control Transmitter
Receiver
Receiver
Transmitter
Product Profiling The height, width or shape of an object can easily be measured using a single axis scanner. ValuScan systems can perform this function directly.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca
Page 3
ValuScan VS6500 measuring light curtains
■
Special Features
ValuScan scanners incorporate several special functions to enhance their versatility. These are built into the operating firmware and can be activated through the setup commands.
Double Scan This allows you to improve resolution in some applications by interpolating between the beams.
Screen Mode Screen Mode allows you to ignore objects under a specific size.
Masking Masking allows you to manipulate the reported status of each beam (for example, inverting the status of the beams to detect holes rather than objects).
Zone Functions This allows you to define up to 8 zones within any scanner. An independent TTL or optional relay output for each zone indicates when an object is detected within the zone.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca
Page 4
ValuScan VS6500
■
Specifications
Optical Performance Minimum Detectable Object* Beam Spacing Normal Scan
Scan Length
DoubleScan Minimum Increment Maximum Range
0.32 in. (8.2 mm)
0.22 in. (5.7 mm)
4.7 in. (120 mm)
4.7 in. (120 mm)
47.2 in. (1200 mm)
16 ft. (4.9 m)
0.45 in. (11.4 mm)
0.33 in. (8.3 mm)
6 in. (152 mm)
6 in. (152 mm)
96 in. (2438 mm)
16 ft. (4.9 m)
0.39 in. (10 mm)
0.59 in. (15.1 mm)
0.40 in. (10.1 mm)
12.6 in. (320 mm)
12.6 in. (320 mm)
37.8 in. (960 mm)
16 ft. (4.9 m)
0.50 in. (12.7 mm)
1.00 in. (25.4 mm)
0.75 in. (19.1 mm)
24 in. (610 mm)
12 in. (305 mm)
72 in. (1829 mm)
80 ft. (24 m)
0.75 in. (19.1 mm)
1.25 in. (31.8 mm)
0.88 in. (22.2 mm)
24 in. (610 mm)
12 in. (305 mm)
72 in. (1829 mm)
80 ft. (24 m)
* Minimum detectable object shown is for non-moving objects measured in a direction parallel to the long axis of the scanner.
Scan Rate: 50 microseconds per beam plus 200 microseconds. (For M5, 0.25, and
Series C & D Controllers:
M10 series, faster scan time may be used with reduced range and short
115 VAC ±10% 50/60 Hz 30 VA maximum power consumption cables.) Note: Scan time is exclusive of serial data communication time.
230 VAC ±10% 50/60 Hz 30 VA maximum power consumption
Serial Communications:
24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power
RS-232 or RS-422 protocol (user selected)
consumption
9,600, 19,200 or 38,400 Baud Rate
Field conversion of operating voltage between 115 VAC and 230 VAC
Parallel Output: (Series A & B Controllers only) 8 bit TTL compatible; 0 to +5 VDC transition; sources or sinks 10 mA. Connection is through male ribbon cable header can be accomplished. Conversion from AC to DC or DC to AC cannot be accomplished. Cable: 98.4 ft. (30 m) maximum Cable diameter is 0.30 in. (7.6 mm).
Relay Output: SPDT Reed Relay; Maximum switching capacity: 25 VDC at 100 mA Do not switch AC loads with this relay. Hardware Trigger: (Series A & B Controllers Only) Optically isolated input. Signal transition between 0 and +5 VDC at 10 mA is required. Maximum current allowed is 20 mA. Positive signal is active. Use a resistor to limit current. Environmental Rating:
Cable connector diameter is 1.35 in. (34.3 mm) Mechanical Endurance: Vibration: 0 to 100 Hz Acceleration: 98 m/s2, 10 G Shock: 4.1 Joules, 3 ft.-lb. Agency Approvals: CSA-CUS, CE Optional Output Cards: (Series A & B Controllers Only)
Temperature Rating: 32 to 131°F (0 to 55°C)
AIC-02 Analog Output: 0 to +10 VDC, -10 to +10 VDC, or 4 to 20 mA
Transmitters and Receivers: NEMA 12, IP65 current sinking (user selectable)
Enclosed controllers: NEMA 12, IP65
ARC-02 Analog Relay Card: 4 SPDT Reed Relays; Maximum switching
Power Requirements:
capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays.
Series A Controllers:
Hysteresis: In beams, multiply 0.016312 times the number of beams
115 VAC ±10% 50/60 Hz 30 VA maximum power consumption and round up to the nearest whole number. For example, 120 beams
230 VAC ±10% 50/60 Hz 30 VA maximum power consumption gives 1.95, which rounds up to 2 beams. It will require clearing at least
24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power
2 beams before the relay will release after it has been energized.
consumption
PRC-02 Parallel Relay Card: 4 SPDT Reed Relays; Maximum switching
Series B Controllers:
capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays.
24 VDC ±10%, 1 VDC P-P maximum ripple, 30 VA maximum power
PRC-08 Parallel Relay Card: 8 SPDT Reed Relays; Maximum switching consumption capacity: 25 VDC at 100 mA. Do not switch AC loads with these relays. PCC-02 Parallel Connection Card: Provides screw terminal connections instead of ribbon cable header for 8-bit parallel output. Specifications are subject to change without notice.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca measuring light curtains
0.20 in. (5 mm) 0.25 in. (6.4 mm)
Page 5
ValuScan VS6500 measuring light curtains
■
Controller Specifications
Two controller styles are available: 1) a serial controller that provides serial data and a relay output, and 2) a VSU controller that provides serial, parallel, relay, and optional analog outputs. Each controller can operate any of the transmitters and receivers. Each controller is available with or without a metal enclosure.
■
Serial Controller: Series C and D
The serial controller is a simple controller designed primarily for OEM applications. It provides serial data and relay outputs only, and is an integrated power supply/controller assembly. It is available as a Series C controller in a compact metal enclosure (rated NEMA 12, IP65) or as a Series D controller printed circuit board assembly without an enclosure. Both series are available for operation on 115 VAC, 230 VAC, or 24 VDC. The serial output can be set to give any of the information shown in the chart below. Serial Controller Dimensions, in./mm 1.69 min. (42.9)
7.40 (188.0)
0.30 Dia mtg holes (8) (7.6) 4.00 (101.6)
r
VS Controller
9.60 (243.8)
10.10 (256.5)
10.80 (274.3)
2.81 (71.4)
6.55 (166.4) SiDe VieW frOnt VieW
2.05 (52.1) BAcK VieW
Standard Outputs Serial Data: RS-232 or RS-422 protocol. Relay Output: SPDT Reed Relay. The relay output can be set to energize when any object is detected or when a minimum number of objects is detected. A special hysteresis function lets you set turn-on and turn-off sizes, allowing the scanner to ignore small objects while detecting larger ones.
Serial Controller Output Information Output Options
✔
Highest beam blocked
✔
Size of an object
✔
Size and location of an object
✔
Position of the center of an object
✔
Total number of beams blocked
✔
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
Serial Data Output
Status of each beam (blocked or clear)
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca
Page 6
ValuScan VS6500
■
VSU Controller: Series A and B
VSU Controller Dimensions, in./mm 7.55 191.8
VS controller
AIC-02 Analog Isolator Card gives an analog
0.30 Dia mtg holes (8) 7.6 4.00 101.6
9.55 242.6 output of 0 to +10 VDC, -10 to +10 VDC, or 4 to 20 mA (current sinking). ARC-02 Analog Relay Card provides four SPDT relays driven by the analog output. Each relay
12.0 305 min has a potentiometer to set its trip point and an 10.80 274.3
10.05 255.3
11.16 284
LED to indicate when the relay is energized. This allows for a stand-alone system to perform simple sorting based on the size or position of an object. PRC-02 Parallel Relay Card provides four
6.55 166.4
4.33 110.0
2.05 52.1 frOnt VieW
SiDe VieW
BAcK VieW
SPDT relays that are switched by four of the TTL parallel outputs. PRC-08 Parallel Relay Card provides eight SPDT relays that are switched by the eight TTL parallel outputs.
Standard Outputs
PCC-02 Parallel Connection Card provides
Serial Data: RS-232 or RS-422 Protocol.
screw terminal connections for the TTL solid
Parallel Output: 8 Bit TTL.
state parallel output.
Relay Output: SPDT reed relay. The relay output can be set to energize when any object is detected or when a minimum number of objects is detected. A special hysteresis function lets you set turn-on and turn-off sizes, allowing the scanner to ignore small objects while detecting larger ones.
VSU Controller Output Information The following chart shows what information is available from each of the outputs. Note that each output can be set for only one function. Output Information Options
Serial Data TTL Parallel Output
Status of each beam (blocked or clear)
✔
Analog
Output*
Output (Optional)
Highest beam blocked
✔
✔
✔
Size of an object
✔
✔
✔
Size and location of an object
✔
Position of the center of an object
✔
✔
✔
Total number of beams blocked
✔
✔
✔
*TTL output has 8 bits and is limited to a maximum of 255 beams.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca measuring light curtains
The VSU controller offers the greatest flexibility and widest range of output options for operating this class of scanner. Series A controllers include a NEMA 12 (IP65) rated metal enclosure and operate on 24 VDC, 115 VAC or 230 VAC. The Series B controller is a single printed circuit board assembly operating on 24 VDC.
Optional Outputs A number of optional output cards are available for use with the VSU controller. All VSU controllers allow one of these cards to be mounted directly on the controller printed circuit board assembly.
Page 7
ValuScan VS6500 measuring light curtains
■
Transmitters & Receivers
The following transmitters and receivers can be used with the serial or VSU controllers. Note: the transmitter and receiver must be of the same series and size. ValuScan - M5 Series The ValuScan M5 Series provides a beam spacing of 0.2 in. (5 mm) resulting in the finest resolution in this class of products. It offers a maximum range of 16 ft. (4.9 m) and is available in sizes of 4.7 to 47.2 in. in 4.7 in. increments (120 to 1200 mm in 120 mm increments). ValuScan - 0.25 Series The ValuScan has a beam spacing of 0.25 in. (6.4 mm). It provides fine resolution at a maximum range of 16 ft. (4.9 m). ValuScan 0.25 Series systems are available in sizes of 6 to 96 in. in 6 in. increments (152 to 2438 mm in 152 mm increments). Choose the 0.25 Series for fine resolution at short to medium range. ValuScan M10 Series The ValuScan M10 transmitters and receivers provide a low cost, medium resolution scanner. They are available with 0.39 in. (10 mm) beam spacing in 12.6, 25.2, and 37.8 in. sizes (320, 640, and 960 mm). The operating range of the M10 Series is 16 ft. (4.9 m) maximum. Choose the M10 Series when low cost is more important than fine resolution.
ValuScan Long Range: 0.50 Series and 0.75 Series These long range ValuScan products are high powered profiling scanners. They are available with 0.5 and 0.75 in. (12.7 and 19.1 mm) beam spacings in 2, 3, 4, 5, and 6 ft. (610, 914, 1219, 1524, and 1829 minimum Object Size Parallel to Scanner mm) sizes. The operating range is 80 ft. (24 m). Choose the ValuScan long range scanners when the highest optical power minimum Object is needed. Size Perpendicular to Scanner
Range and Minimum Detectable Object The maximum range (distance between the transmitter and receiver) and minimum detectable object size vary with the ValuScan series. See the chart below for specific information. US Dimensions Minimum Detectable Object* Orientation* Beam
Operating
Perpendicular
Parallel
Series
Spacing Range Normal or DoubleScan Normal Scan DoubleScan
M5
0.2 in.
16 ft.
0.33 in.
0.32 in.
0.22 in.
0.25
0.25 in.
16 ft.
0.20 in.
0.45 in.
0.33 in.
M10
0.39 in.
16 ft.
0.20 in.
0.59 in.
0.40 in.
0.50
0.50 in.
80 ft.
0.5 in.
1.00 in.
0.75 in.
0.75
0.75 in.
80 ft.
0.5 in.
1.25 in.
0.88 in.
Metric Dimensions Minimum Detectable Object* Orientation* Beam Series
Operating
Perpendicular
Parallel
Spacing Range Normal or DoubleScan Normal Scan DoubleScan
M5
5 mm
4.9 m
8.3 mm
8.2 mm
5.7 mm
0.25
6.4 mm
4.9 m
5.1 mm
11.4 mm
8.3 mm
M10
10 mm
4.9 m
5.1 mm
15.1 mm
10.1 mm
0.50
12.7 mm
24 m
12.7 mm
25.4 mm
19.1 mm
0.75
19.1 mm
24 m
12.7 mm
31.8 mm
22.2 mm
* Minimum detectable objects shown are typical values for static (non-moving) objects. Actual values will vary with individual applications. See drawing above for orientation. For moving objects this size must be increased by the scan time multiplied by the speed of the object in the direction of motion. DoubleScan minimum detectable object sizes are determined at the mid-point between the transmitter and receiver.
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca
Page 8
ValuScan VS6500
Available Types of Transmitters & Receivers Scan Length Number of Beams
Scan Length Number of Beams
US Metric Normal Scan Double Scan
US Metric Normal Scan Double Scan
M5
4.7 in.
120 mm
24
48
M10
12.6 in.
320 mm
32
64
M5
9.4 in.
240 mm
48
96
M10
25.2 in.
640 mm
64
128
M5
14.2 in.
360 mm
72
144
M10
37.8 in.
960 mm
96
192
M10
50.4 in.
1280 mm
128
256
M5
18.9 in.
480 mm
96
192
M5
23.6 in.
600 mm
120
240
M5
28.3 in.
720 mm
144
288
M5
33.1 in.
840 mm
168
336
0.50
24 in.
610 mm
48
96
36 in.
914 mm
72
144
M5
37.8 in.
960 mm
192
384
0.50
M5
42.5 in.
1080 mm
216
432
0.50
48 in.
1219 mm
96
192
M5
47.2 in.
1200 mm
240
480
0.50
60 in.
1524 mm
120
240
0.50
72 in.
1829 mm
144
288
64
0.25
6 in.
152 mm
24
48
0.25
12 in.
305 mm
48
96
0.75
24 in.
610 mm
32
144
0.75
36 in.
914 mm
48
96
48 in.
1219 mm
64
128
0.25
18 in.
457 mm
72
0.25
24 in.
610 mm
96
192
0.75
0.25
30 in.
762 mm
120
240
0.75
60 in.
1524 mm
80
160
0.25
36 in.
914 mm
144
288
0.75
72 in.
1829 mm
96
192
0.25
42 in.
1067 mm
168
336
0.25
48 in.
1219 mm
192
384
0.25
54 in.
1372 mm
216
432
0.25
60 in.
1524 mm
240
480
0.25
66 in.
1676 mm
264
528
0.25
72 in.
1829 mm
288
576
0.25
78 in.
1981 mm
312
624
0.25
84 in.
2134 mm
336
672
0.25
90 in.
2286 mm
360
720
0.25
96 in.
2438 mm
384
768
Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 measuring light curtains
Series
Series
For the Latest Information On the Internet: www.stiscanners.com or www.omron.ca