Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of CPM1A Micro Programmable Controller

Manual · Omron

CPM1A Micro Programmable Controller

Manual22 pagesPDF 436 KB

Omron catalog for the CPM1A micro programmable controller series, its expansion modules (including the CPM1A-TS101-DA) and specifications.

What this file really is

The old site listed this file as “Configuration Manual” for the Omron CPM1A-TS101-DA. This is not a configuration manual for the CPM1A-TS101-DA; it is Omron's catalog for the whole CPM1A micro programmable controller series, which lists the TS101-DA among its temperature sensor modules.

Download the PDF436 KB

Filed under · 1 model

Filed under these models in the old catalog

Summary

What is in it

Omron's product catalog for the CPM1A series of brick style micro programmable controllers. It lists the CPU units with 10, 20, 30 and 40 I/O points, expansion I/O modules, and dedicated modules for analog I/O, temperature sensor inputs (among them the CPM1A-TS101-DA platinum resistance thermometer module with an analog output) and CompoBus/S links. It gives specifications, dimensions, functions, communications and the instruction set.

Its parts

  1. Features
  2. Basic Configuration
  3. Ordering Information
  4. Specifications
  5. Dimensions
  6. Functions
  7. Communications
  8. Instruction Set

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

This is Omron's catalog for the CPM1A Micro Programmable Controller series, covering CPU units, expansion and dedicated I/O modules, including the CPM1A-TS101-DA temperature sensor module with an analog output that the site files it under. It gives ordering part numbers, specifications and dimensions for each unit. It also explains functions such as interrupts, high-speed counting and pulse output, the communication links and the instruction set.

Module
Temperature sensor input module: 2 platinum resistance thermometer inputs (Pt100, JPt100) and 1 analog output p. 2
Input range
Pt100 and JPt100: –200.0 to 650.0°C (–300 to 1200.0°F) p. 10
Analog output
Voltage or current; resolution 1/256 (0 to 10 V), 1/512 (–10 to +10 V), 1/256 (4 to 20 mA); 1.0% max. full scale p. 9
Isolation
Photocoupler isolation between I/O terminals and the PLC p. 9
Max. modules
3 max. p. 2
Data to the CPU
Readings converted to binary data and stored in the CPM1A IR area p. 9
Module size
Width 86 mm (3.39 in), height 90 mm (3.54 in) p. 11
CPM1A CPU I/O
CPM1A CPU: 10, 20, 30 and 40 point I/O, expandable up to 100 I/O points p. 1
CPM1A CPU power
CPM1A CPU: 100 to 240 VAC, 50/60 Hz, or 24 VDC p. 4
CPM1A CPU memory
CPM1A CPU: 2,048 words program capacity; 1,024 words user data memory p. 5
CPM1A operating temperature
CPM1A CPU: 0°C to 55°C (32°F to 131°F) p. 4
Communications adapters
CPM1-CIF01 (RS-232C) and CPM1-CIF11 (RS-422/RS-485) for the peripheral port p. 3
Programming software
CX-Programmer Jr. WS02-CXPC1-EJR-V2.0; CX-Programmer WS02-CXPC1-EV2.0 p. 3
Program transfer
CPM1-EMU01-V1 Expansion Memory Unit with CPM1-EEPROM-EMU01 (256 kbits) p. 3

What this manual walks you through

  • Choosing CPU units, expansion and dedicated I/O modules by part number p. 2, 3
  • Setting temperature sensor input ranges with the rotary switch p. 10
  • Using interrupt inputs and quick-response inputs p. 13, 14
  • Using the high-speed counter p. 15
  • Interval timer interrupts and the analog setting controls p. 16, 17
  • Pulse output for stepping motor or servo positioning p. 17
  • NT Link, Host Link and 1:1 Link communications p. 18, 19
  • Copying programs with the Expansion Memory Unit p. 19
  • Instruction set and function codes p. 20, 21, 22
  • Unit dimensions, with and without peripheral devices p. 11, 12

Good to know

  • On the temperature sensor modules, the same input type must be used for all inputs. p. 9
  • CPM1A 1:1 links are limited to 16 words, LR 00 to LR 15. p. 19
  • The speed output and set pulses instructions work only on CPM1A transistor output models. p. 22
  • The catalog states specifications are subject to change without notice. p. 22

Questions this manual answers

What sensors does the CPM1A-TS101-DA accept?

Two platinum resistance thermometer inputs, Pt100 or JPt100. The same input type must be used for all inputs. p. 2, 9

What temperature range does the CPM1A-TS101-DA measure?

–200.0 to 650.0°C (–300 to 1200.0°F), for both Pt100 and JPt100. p. 10

What analog output does the CPM1A-TS101-DA have?

One voltage or current output, listed for 0 to 10 V, –10 to +10 V and 4 to 20 mA, with 1.0% max. full scale accuracy. p. 9

What software programs the CPM1A?

CX-Programmer (WS02-CXPC1-EV2.0) or CX-Programmer Jr. (WS02-CXPC1-EJR-V2.0), which runs on Windows 95/98/NT. p. 3

How does a CPM1A connect to a PC?

Through the CPM1-CIF01 RS-232C adapter on the peripheral port, with the C200HS-CN220-EU 2 m cable for program download. p. 3

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Features1
  2. Basic Configuration1
  3. Ordering Information2
  4. Specifications4
  5. Dimensions11
  6. Functions13
  7. Communications18
  8. Instruction Set20
  9. Contact Omron22

From the PDF’s own bookmarks.

The whole text · 3 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Pages 9 to 169-16
  3. Pages 17 to 2217-22

The file

Revision and size

RevisionCat. No. GC MSPLC1, 03/01
PublisherOMRON Electronics LLC
Pages22
PDF436 KB
TextText from the PDF itself.

The first pages · 3 of 22

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 22
Page 2
Page 2of 22
Page 3
Page 3of 22

More documents · 1

For the same models