Page 141

MIB

APPENDIX B " hlitThreshold OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION ”When the WTP exceeds this time while servicing a transmit request, the hlitThreshCount will be incremented. Time is in hundredths of seconds.” ::= { hlit 5 } hlitThreshCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”When the WTP exceeds the time in hlitThreshold, this count is incremented. Time in hundreths of seconds.” ::= { hlit 6 } hlitLongest OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”This is the maximum time that the WTP took to service transmit requests. Time is in hundreths of seconds.” ::= { hlit 7 } wcbst

OBJECT IDENTIFIER ::= { nTransport 4 } wcbstReset OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION ”Reset variable for the wcbs table” ::= { wcbst 1 } wcbstLastReset OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION ”Elapsed time since the wcbs table was reset” ::= { wcbst 2 } RC4030E Gateway User’s Guide

B-39

Page 142

APPENDIX B "

MIB wcbsTable OBJECT-TYPE SYNTAX SEQUENCE OF WcbsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”WTP connection control block statistics table. Each entry is for an WTP connection statistics object. Statistics are per WTP connection.” ::= { wcbst 3 } wcbsEntry SYNTAX WcbsEntry ACCESS not-accessible STATUS mandatory INDEX { wcbstIndex } ::= { wcbsTable 1 }

OBJECT-TYPE

WcbsEntry ::= SEQUENCE { wcbstIndex INTEGER, wcbstInUse INTEGER, wcbstHlState INTEGER, wcbstDsap INTEGER, wcbstSsap INTEGER, wcbstNet16Addr INTEGER, wcbstT1Value INTEGER, wcbstT1Average INTEGER, wcbstT1Deviation INTEGER, wcbstT1Timeouts Counter, wcbstT2Timeouts Counter, wcbstTiTimeouts Counter, wcbstFramesRecv Counter, wcbstIframesRecv Counter, wcbstIframesDiscarded Counter, wcbstDataBytesRecv Counter, wcbstFramesXmit Counter, wcbstIframesXmit Counter, wcbstDataBytesXmit Counter, wcbstIframesRetransmitted Counter, wcbstState INTEGER }

B-40

RC4030E Gateway User’s Guide

Page 143

APPENDIX B "

MIB wcbstIndex OBJECT-TYPE SYNTAX INTEGER (1..999) ACCESS read-only STATUS mandatory DESCRIPTION ”Connection control block identifier” ::= { wcbsEntry 1 } wcbstInUse OBJECT-TYPE SYNTAX INTEGER (0..1) ACCESS read-only STATUS mandatory DESCRIPTION ”This variable is 1 if the control block is in use.” ::= { wcbsEntry 2 } wcbstHlState OBJECT-TYPE SYNTAX INTEGER (0..9999) ACCESS read-only STATUS mandatory DESCRIPTION ”The control block state. 0=closed, 1=busy, 2=connect, 3=listen, 4=unitdata, 5=unitdata listen, 6=open, 7=send, 8=closing, 9=disconnect.” ::= { wcbsEntry 3 } wcbstDsap OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION ”Destination service access point.” ::= { wcbsEntry 4 } wcbstSsap OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION ”Source service access point” ::= { wcbsEntry 5 }

RC4030E Gateway User’s Guide

B-41

Page 144

APPENDIX B "

MIB wcbstNet16Addr OBJECT-TYPE SYNTAX INTEGER (2048..9192) ACCESS read-only STATUS mandatory DESCRIPTION ”The 16-bit network address of the remote node which is active on the connection, if the control block is in an active state.” ::= { wcbsEntry 6 } wcbstT1Value OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION ”The current response time-out value in tenths of seconds.” ::= { wcbsEntry 7 } wcbstT1Average OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION ”The average response time-out value in tenths of seconds.” ::= { wcbsEntry 8 } wcbstT1Deviation OBJECT-TYPE SYNTAX INTEGER (0..999) ACCESS read-only STATUS mandatory DESCRIPTION ”The average deviation from the T1Average values in tenths of seconds.” ::= { wcbsEntry 9 } wcbstT1Timeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Number of T1 timeouts. A T1 timeout occures when an expected response is lost.” ::= { wcbsEntry 10 } B-42

RC4030E Gateway User’s Guide

Page 145

MIB

APPENDIX B " wcbstT2Timeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Number of T2 timeouts. A T2 timeout occures if the higher layer does not have data ready to send before an WTP supervisory response is required.” ::= { wcbsEntry 11 } wcbstTiTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Number of Ti timeouts. A Ti timeout occures when a connection is idle for an INACITVE TIMEOUT period.” ::= { wcbsEntry 12 } wcbstFramesRecv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP frames received.” ::= { wcbsEntry 13 } wcbstIframesRecv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP data frames received.” ::= { wcbsEntry 14 } wcbstIframesDiscarded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP data frames which were discarded as duplicates.” ::= { wcbsEntry 15 }

RC4030E Gateway User’s Guide

B-43

Page 146

APPENDIX B "

MIB wcbstDataBytesRecv OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of data bytes received.” ::= { wcbsEntry 16 } wcbstFramesXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP frames transmitted.” ::= { wcbsEntry 17 } wcbstIframesXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP data frames transmitted.” ::= { wcbsEntry 18 } wcbstDataBytesXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of WTP data frames transmitted.” ::= { wcbsEntry 19 } wcbstIframesRetransmitted OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Total number of data frames which were lost and had to be retransmitted.” ::= { wcbsEntry 20 } wcbstState OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The internal software state of the LLC control block.” ::= { wcbsEntry 21 } B-44

RC4030E Gateway User’s Guide

Page 147

APPENDIX B " nApplication

MIB

OBJECT IDENTIFIER ::= { norandNET 104 } gwSession

OBJECT IDENTIFIER ::= { nApplication 1 } gs

OBJECT IDENTIFIER ::= { gwSession 1 } gsReset OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION ”Reset variable for the gs group” ::= { gs 1 } gsLastReset OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION ”The time elapsed since the last reset of gs group” ::= { gs 2 } -- The Gateway Statistics group gsClockTicks OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of .01 second timer ticks since the timer was reset.” ::= { gs 3 } gsNetworkErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of times the network has been lost.” ::= { gs 4 } gsHostDataCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of data blocks received from the host computer.” ::= { gs 5 } RC4030E Gateway User’s Guide

B-45

Page 148

APPENDIX B "

MIB gsHostHaltCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of HALT commands received from the host task.” ::= { gs 6 } gsHostInvalidCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of invalid messages received from the host task.” ::= { gs 7 } gsHostDiscardCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of blocks from the host computer which were discarded.” ::= { gs 8 } gsConnectCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”The total number of transport connections.” ::= { gs 9 } gsCloseCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of times a transport connection was closed.” ::= { gs 10 }

B-46

RC4030E Gateway User’s Guide

Page 149

APPENDIX B "

MIB gsBlocksXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of blocks passed to the network” ::= { gs 11 } gsDataXmit OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of data blocks passed to the network” ::= { gs 12 } gsBlocksRecv OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of blocks received from the network” ::= { gs 13 } gsDataRecv OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of data blocks received from the network.” ::= { gs 14 } gsTermResetCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of times a session was reset by a terminal” ::= { gs 15 }

RC4030E Gateway User’s Guide

B-47

Page 150

APPENDIX B "

MIB gsTermContinueCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of times a session was continued after a transport connection was lost.” ::= { gs 16 } gsTermInvalidCount OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of invalid blocks received from terminals.” ::= { gs 17 } gsConnectionErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of transport connection errors.” ::= { gs 18 } gsConnectionResets OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of times an active transport connection was reset.” ::= { gs 19 } gsRetransmissions OBJECT-TYPE SYNTAX Counter ACCESS read-only --read-reset STATUS mandatory DESCRIPTION ”Number of data blocks which were retransmitted.” ::= { gs 20 }

B-48

RC4030E Gateway User’s Guide