Page 121

MIB

APPENDIX B "

Table B-14 (Continued) rcbs GROUP Gateway (Terminal Emulation) Session Table (each record is a terminal session) norand.manage.norandNet.nApplication.gwSession.rcbs.x (1.3.6.1.4.1.469.1000.2.104.1.2.x) OID 4.1.26 4.1.27 4.1.28 4.1.29 4.1.30

Object Name rcbsTermDelayLongest rcbsTermThresholdCount rcbsTermMaxCount rcbsTermDelayTraceOn rcbsHostAlias

Object Type INTEGER Counter Counter INTEGER DisplayString

Access read read read write read

Table B-15 hd GROUP Host Delay Statistics norand.manage.norandNet.nApplication.gwSession.hd.x (1.3.6.1.4.1.469.1000.2.104.1.3.x) OID 4.1.1 4.1.2 4.1.3

Object Name hdHostDelay hdCount hdBucket

Object Type INTEGER Counter INTEGER

Access write read read

Table B-16 td GROUP Terminal Transaction Delay Statistics norand.manage.norandNet.nApplication.gwSession.td.x (1.3.6.1.4.1.469.1000.2.104.1.4.x) OID 4.1.1 4.1.2 4.1.3

Object Name tdTrxnTime tdCount tdBucket

Object Type INTEGER Counter INTEGER

Access write read read

RC4030E Gateway User’s Guide

B-19

Page 122

APPENDIX B "

MIB

Table B-17 ahost GROUP Asynchronous Host norand.manage.norandNet.nApplication.ahost.x (1.3.6.1.4.1.469.1000.2.104.2.x)

B-20

OID

Object Name

Object Type Access

1 ahstReset

INTEGER write

2 ahstLastReset

TimeTicks read

3 ahstFramesOut

Counter read

4 ahstFramesIn

Counter read

5 ahstIdleDetected

Counter read

6 ahstNoErrors

Counter read

7 ahstSyntaxErrors

Counter read

8 ahstLengthErrors

Counter read

9 ahstDisabledErrors

Counter read

10 ahstGapErrors

Counter read

11 ahstCheckErrors

Counter read

12 ahstNoBuffersErrors

Counter read

13 ahstSequenceErrors

Counter read

15 ahstParityErrors

Counter read

16 ahstFrameErrors

Counter read

17 ahstNoiseErrors

Counter read

18 ahstBreakErrors

Counter read

RC4030E Gateway User’s Guide

Page 123

MIB

APPENDIX B "

Control Group The objects in the following group exerts control over the RC4030E Gateway. Present functions include rebooting. " NOTE:

The MIB definition for this group starts on the page given below. " powerUp Power Up Objects (page B-68) Table B-18 powerUp GROUP Device Power Up Objects norand.manage.norandNet.nControl.powerUp.x (1.3.6.1.4.1.469.1000.2.105.1.x)

OID

Object Name

Object Type Access

1 pwrPowerUpCount

Counter read

2 pwrNextPowerUpTime

TimeTicks write

MIB Definitions Following are the MIB definitions for the RC4030E Gateway.

RC4030E Gateway User’s Guide

B-21

Page 124

APPENDIX B "

MIB

-- ****************************************************************** -- * -- * 4030MIB.MIB Version 1.32 -- * -- ****************************************************************** OWL DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI PhysAddress, DisplayString FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; ---

This MIB module uses the extended OBJECT-TYPE macro as defined in RFC-1212;

norand manage products ap6710 gw4030 wnas ts6950 gwap6910 uap2100 msd6710 norandNET nSystem hw

OBJECT IDENTIFIER ::= { enterprises 469 } OBJECT IDENTIFIER ::= { norand 1000 } OBJECT IDENTIFIER ::= { manage 1 } OBJECT IDENTIFIER ::= { products 1 } OBJECT IDENTIFIER ::= { products 2 } OBJECT IDENTIFIER ::= { products 3 } OBJECT IDENTIFIER ::= { products 4 } OBJECT IDENTIFIER ::= { products 5 } OBJECT IDENTIFIER ::= { products 6 } OBJECT IDENTIFIER ::= { products 7 } OBJECT IDENTIFIER ::= { manage 2 } OBJECT IDENTIFIER ::= { norandNET 1 } OBJECT IDENTIFIER ::= { nSystem 1 }

-- The Hardware Parameters Group hwPartNo OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The Norand part number of the hardware device.” ::= { hw 1 }

B-22

RC4030E Gateway User’s Guide

Page 125

APPENDIX B "

MIB hwDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION ”The description of the hardware device.” ::= { hw 2 } hwRevision OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The revision level of the hardware device.” ::= { hw 3 } hwSerialNo OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The serial number of the hardware device.” ::= { hw 4 } hwID OBJECT-TYPE SYNTAX INTEGER (0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION ”The device identifier of the hardware device. Values = 3250, 4000, 4020, 4030, 4033, 3240, 1000, 1100, 1700, 5940, 4650, 100 (ACE process), 200 (DOSNMS), 300 (Norand Proxy Agent), 6710 (Access Point).” ::= { hw 5 } file dir

OBJECT IDENTIFIER ::= { nSystem 3 } OBJECT IDENTIFIER ::= { file 3 }

-- The File Directory Table -- Table Definition dirTable OBJECT-TYPE SYNTAX SEQUENCE OF DIREntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”The FileSystem Directory” ::= { dir 2 } RC4030E Gateway User’s Guide

B-23

Page 126

APPENDIX B "

MIB

-- Row Definition dirEntry OBJECT-TYPE SYNTAX DIREntry ACCESS not-accessible STATUS mandatory INDEX { dirIndex } ::= { dirTable 1 } -- Columnar Object Definitions DIREntry ::= SEQUENCE { dirIndex INTEGER, dirName DisplayString, dirSegment INTEGER, dirType INTEGER, dirSize INTEGER, dirDate DisplayString, dirTime DisplayString, dirVersion DisplayString } dirIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Directory Index” ::= { dirEntry 1 } dirName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..14)) ACCESS read-only STATUS mandatory DESCRIPTION ”File name” ::= { dirEntry 2 } dirSegment OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION “File segment (1 - (NUM_SEGMENTS + 1)). The segment ID which identifies the segment containing the file.” ::= { dirEntry 3 } B-24

RC4030E Gateway User’s Guide

Page 127

MIB

APPENDIX B " dirType OBJECT-TYPE SYNTAX INTEGER { executable(1), data(2), invalid(3) } ACCESS read-only STATUS mandatory DESCRIPTION ”File type: executable = 1, data = 2, invalid = 3 ” ::= { dirEntry 4 } dirSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”The file size in bytes” ::= { dirEntry 5 } dirDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file date in MM-DD-YYYY display format.” ::= { dirEntry 6 } dirTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file time in HH:MM:SS display format.” ::= { dirEntry 7 } dirVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION ”The file version in v99.99 display format.” ::= { dirEntry 8 } sysErrors

OBJECT IDENTIFIER ::= { nSystem 4 } criticalErrors OBJECT IDENTIFIER ::= { sysErrors 1 } RC4030E Gateway User’s Guide

B-25

Page 128

APPENDIX B "

MIB ceEnabled OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-only STATUS mandatory DESCRIPTION ”A value of true(1) signifies that the critical error log was successfully initialized as part of the power-up sequence. Any errors in that initialization process result in a value of false(2).” ::= { criticalErrors 1 } ceOverflow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Overflow error code. If the overflow code is non-zero, it indicates that the log has overflowed and the overflow code contains the last displaced value.” ::= { criticalErrors 2 } ceReset OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } ACCESS read-write STATUS mandatory DESCRIPTION ”A user can reset the critical error log by setting ceReset to true(1). Valid values are true(1) or false(2).” ::= { criticalErrors 3 } ceLogTable OBJECT-TYPE SYNTAX SEQUENCE OF CELogEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”Critical Error Log Table” ::= { criticalErrors 4 } ceLogEntry OBJECT-TYPE SYNTAX CELogEntry ACCESS not-accessible STATUS mandatory INDEX { ceLogErrorCode } ::= { ceLogTable 1 } B-26

RC4030E Gateway User’s Guide

Page 129

MIB

APPENDIX B "

CELogEntry ::= SEQUENCE { ceLogErrorCode INTEGER, ceLogErrorCount Counter } ceLogErrorCode OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION ”Critical error code. A 16-bit value which uniquely indentifies a system software error. The error codes are intended for internal Norand use.” ::= { ceLogEntry 1 } ceLogErrorCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION ”Error count for the associated ceLogErrorCode” ::= { ceLogEntry 2 } nSNMP

OBJECT IDENTIFIER ::= { norandNET 11 } v1Config

OBJECT IDENTIFIER ::= { nSNMP 1 }

--Norand Community table defines the accepted --community strings and their access privileges -- The Community Table

RC4030E Gateway User’s Guide

B-27

Page 130

APPENDIX B "

MIB communityTable OBJECT-TYPE SYNTAX SEQUENCE OF CommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”The community table is used to define communities and their access privileges. Norand’s implementation of the community table has some special considerations: 1) GETs and SETs to the community table can only be accomplished using the SUPER-USER community string which Norand has defined; 2) This SUPER-USER community string, or password, is defined in the first row of the community table. The communityName contained in the first row of the community table is always the SUPER-USER community string. This community string (communityName) may be modified. 3) All rows of the community table are modifiable (SET) when using the SUPER-USER community string. However, for the first row of the community table, only the communityName object is modifiable. This ensures that the SUPER-USER will always have maximum access to the MIB data. All other rows in the community Table are accessible as defined in the MIB definition. 4) The SUPER-USER and other default community string values can be found in Norand’s User’s Guide.” ::= { v1Config 2 } -- Row Definition communityEntry OBJECT-TYPE SYNTAX CommunityEntry ACCESS not-accessible STATUS mandatory DESCRIPTION ”Each entry relates to a specific community & associates to it access privileges.” INDEX { communityIndex } ::= {communityTable 1 } -- Columnar Object Definition B-28

RC4030E Gateway User’s Guide