Page 163

APPENDIX A sdStatus SYNTAX INTEGER {

"

MIB

OBJECT-TYPE sdPending(1), sdSTStopped(2), sdInProcess(3), sdTerminated(4), sdSuccess(5), sdError(6), pwrNPUT(7), tftpError(8)

} ACCESS read-only STATUS mandatory DESCRIPTION ”Status of the current software download” ::= { softwareDownLoad 4 } sdErrorString OBJECT-TYPE SYNTAX DisplayString (SIZE (0..40)) ACCESS read-only STATUS mandatory DESCRIPTION ”Description of sdStatus field” ::= { softwareDownLoad 5 } sdCheckPoint OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION ”An application variable intended to contain a number relating the progress of the current software download” ::= { softwareDownLoad 6 } sdSetActivePointers OBJECT-TYPE SYNTAX INTEGER { none(1), boot(2), data(3), both(4) } ACCESS read-write STATUS mandatory DESCRIPTION ”If the device reboots due to the expiration of the pwrNextPwrUpTime timer, this value specifies which active pointers will be toggled prior to rebooting” ::= { softwareDownLoad 7 }

6910 Integrated and 6910 Telnet Gateway/Access Points User’s Guide

A-111

Page 164

APPENDIX A

"

MIB sdTerminate SYNTAX INTEGER {

OBJECT-TYPE true(1), false(2)

} ACCESS read-write STATUS mandatory DESCRIPTION ”Terminate the current software download” ::= { softwareDownLoad 8 } END

A-112