For the Monarch 9450 Rascal

Page 71

Appendix B. Format Specification Data

Density Density defines the wide to narrow bar code element in dot rows. The chart below shows the available densities for each bar code. Bar Code UPCA UPCA+2 UPCA+5 UPCE UPCE+2 UPCE+5 EAN8 EAN13 Code 39 l 2 of 5 Codabar Code 128a Code 128b Code 128c MSI

Densities 1, 2 1, 2 1, 2 1, 2 1, 2 1, 2 1, 2 1, 2 3, 4, 5, 6, 7, 8 6, 7, 8, 9, 10, 11, 13, 15 4, 5, 6, 7, 9, 10 9, 12, 19 9, 12, 19 9, 12, 19 4, 6, 9

Maximum Field Length Enter the maximum number of characters for the bar code field. Operator Prompt Text to be used to prompt the operator to enter data. The line is displayed above the data entry area for the field.

B-3

Page 72

9450 User’s Manual

Field Specification Data--Text Fields Select a font and point size from the displayed list. NOTE: To view additional font selections, type N and press ENTER. To view the previous font selections, type P and press ENTER.

Character Soft Fonts The following table shows the 9450 soft fonts with available point sizes. CG Triumvirate Bold Point Cell Height Size

Nominal Width

Nominal Height

6.5

0.098" 2.51 mm

20 dots

0.039" 1 mm

8 dots

0.054" 1.38 mm

8

0.123" 3.153 mm

25 dots

0.049" 1.256 mm

10 dots

0.068" 14 dots 1.743 mm

10

0.152" 3.897 mm

31 dots

0.059" 1.512 mm

12 dots

0.083" 17 dots 2.128 mm

12

0.177" 4.538 mm

36 dots

0.073" 1.871 mm

15 dots

0.108" 22 dots 2.769 mm

18*

0.256" 6.564 mm

52 dots

0.231" 5.923 mm

47 dots

0.256" 52 dots 6.564 mm

22*

0.310" 7.948 mm

63 dots

0.275" 7.051 mm

56 dots

0.310" 63 dots 7.948 mm

* indicates point size only supports numeric characters.

B-4

11 dots

Page 73

Appendix B. Format Specification Data

CG Triumvirate Bold Condensed Point Cell Height Size

Nominal Width

Nominal Height

6.5

0.103" 2.641 mm

21 dots

0.029" 0.743 mm

6 dots

0.054" 11 dots 1.384 mm

8

0.123" 3.153 mm

25 dots

0.039" 1 mm

8 dots

0.073" 15 dots 1.871 mm

10

0.147" 3.769 mm

30 dots

0.049" 1.256 mm

10 dots

0.088" 18 dots 2.256 mm

12

0.172" 4.410 mm

35 dots

0.054" 1.384 mm

11 dots

0.108" 22 dots 2.769 mm

18*

0.246" 6.307 mm

50 dots

0.206" 5.282 mm

42 dots

0.246" 50 dots 6.307 mm

22*

0.295" 7.564 mm

60 dots

0.246" 6.307 mm

50 dots

0.295" 60 dots 7.564 mm

* indicates point size only supports numeric characters. Field Orientation The field can be printed in two directions: 1 2 left to right (normal) top to bottom

NOTE: Refer to the instruction box at the top of the display for an example of each orientation. Height Magnification The magnification for the character height. The possible magnifications are 1, 2, 3, and 4. Width Magnification The magnification for the character width. The possible magnifications are 1, 2, 3, and 4. Field Contrast You can print black characters on a white background (NORMAL) or white characters on a black background (REVERSE). If you choose Reverse, a border area is also printed around the text.

B-5

Page 74

9450 User’s Manual

Data Source The data source for the field can be one of the following:

Fixed

The exact data you entered in the field. The field is always printed with that value.

When Printed

The field data is variable. When you print the label, the program prompts you to fill in the value of the field. You can change the value for each set of labels printed. NOTE: If the field is a "When Printed" field, it is displayed as a string of question marks on the format display.

Characters Per Line If you define the field as "When Printed," enter the number of characters per line for the field. Number of Lines If you define the field as "When Printed," enter the number of lines to appear in the field. If you enter a value of more than one for this field, the operator who prints the labels will be able to type multiple lines of text by using /n to represent a carriage return. Refer to Chapter 5, "Printing," for more information. Justify If you define the field as "When Printed," specify whether you want the characters to print flush left (L), right (R), or centered (C) in the field. Operator Prompt If you define the field as "When Printed," enter text to be used as a prompt for the operator.

B-6

Page 75

Appendix B. Format Specification Data

Increment Field If you define the field as "Fixed," you can define these options:

Increment the field

A number added to the field value for each batch of labels requested when printing. This option is typically used in applications where a unique number such as a serial number is required on each label. The number increments by 1.

Decrement the field

A number subtracted from the field value for each batch of labels requested when printing. The number decrements by 1.

Constant

The field will not be incremented/decremented. If the field value is not numeric, no incrementing/decrementing will occur. If the field contains letters and numbers, the increment/decrement applies only to the numeric portion at the end of the field. Example: For the field "45 ABC 23," only "23" is incremented.

Fixed Data If you define the field as "Fixed," enter the value of the field. You can type multiple lines of text by using /n to represent a carriage return. Refer to Chapter 5, "Printing," for more information.

B-7

Page 76

9450 User’s Manual

B-8

Page 77

Appendix C. Messages Following are status messages you could receive while using the 9450 software. Each is accompanied by an explanation as well as a possible solution. NOTE: Some Terminate and Stay Resident programs (TSR’s) may cause problems with the 9450 software. You may want to disable TSR’s when running 9450. Monarch does not recommend running the 9450 program under the Windows shell. Message Error on printer.

Description This is the most common error message you will encounter. One of the following may have caused this problem: You ran 9450.EXE, not RUN9450.BAT. Try running the RUN9450.BAT file. Your cable is not attached to the correct communications port. Make sure it is connected to the correct port. The Flow Control on your printer is not set to DTR. Set it to DTR. Decimal value = 128 for DTR.

C-1

Page 78

9450 User’s Manual

Different DOS versions of MODE.COM, PRINT.COM, or PRINT.EXE are loaded into the 9450 directory. If you have a path statement to DOS in your AUTOEXEC.BAT file, you do not need these files in the 9450 sub-directory. Be sure to delete them. Your printer may be offline. Make sure the printer is turned on and online. 101 Error erasing label file.

The batch or format file you are trying to delete cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

102 Error erasing report file.

The batch or format file you are trying to delete cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

103 Error opening label file.

The batch or format file you are trying to open cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

C-2

Page 79

Appendix C. Messages

Message 104 Error reading label file.

Description The batch or format file you are trying to read cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

105 Error reading label file.

The batch or format file you are trying to read cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

106 Error reading label file.

The batch or format file you are trying to read cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

107 Error reading label file.

The batch or format file you are trying to read cannot be found. System error. Shut down your system and start over. If you receive this message again, call Monarch Technical Support.

108 Early end of file on label file - label file damaged.

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

C-3

Page 80

9450 User’s Manual

Message 109 Too many fields in label file - label file damaged.

Description There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

110 Too many pictures on label file.

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

111 Error reading label

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

112 Error closing label file.

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

113 Error creating or opening label file.

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.

114 Error reading label file.

There is something wrong with the label file. Restart the system. The format may be lost. If so, recreate it.