The two-page operating instructions from E-One Moli Energy for the MQC-1821B Li-ion Charger, a desktop charger for Molicel MCR-1821 lithium-ion battery packs. They explain how to power the charger, charge a pack and read the status indicator, and list the specifications and safety cautions.

Device
Fully automatic desktop Li-ion charger with a charge status indicator p. 1, 2
Battery
Molicel MCR-1821 lithium-ion battery packs; not recommended for MCR-1821C p. 2
Charge output
8.4 VDC @ 550 mA max. p. 2
AC adapter
Supplied adapter rated 9 Volt, 700 mA p. 2
Charging time
Typically 4-5 hours (MCR1821J) p. 2
Status indicator
Green when powered or when the pack is full; red while charging; flashing when the temperature is out of range p. 2
Operating temperature
10°C (50°F) to 45°C (112°F) p. 2
Weight
75g p. 2
Dimensions
69 mm (W) x 46 mm (H) x 61 mm (T) p. 2
Short circuit protection
Built-in protection against accidental shorting of the output contacts p. 2

What this manual walks you through

  • Powering the charger from its AC adapter p. 2
  • Charging a battery pack p. 2
  • Reading the status indicator p. 2

Good to know

  • Power the charger only from the AC adapter supplied with it. p. 2
  • Not recommended for Molicel MCR-1821C batteries. p. 2
  • For indoor use only, away from moisture, and with the rear vent holes uncovered. p. 2
  • The charger may become warm while charging; the instructions call this normal. p. 2
  • The manual states approvals of CE for the charger and UL, ULC for the adapter. p. 2

Questions this manual answers

What battery does the Molicel MQC-1821B charge?

Molicel MCR-1821 lithium-ion battery packs. It is not recommended for MCR-1821C batteries. p. 2

How long does the MQC-1821B take to charge a battery?

Typically 4-5 hours for an MCR1821J pack. p. 2

Why is the light on my Molicel charger flashing?

A flashing status indicator means the operating temperature is out of range; the charger works from 10°C to 45°C. p. 2

What AC adapter does the MQC-1821B use?

The adapter supplied with it, rated 9 Volt, 700 mA, plugged into the back of the charger. p. 2

The file

Size and text

Pages2
PDF29 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Molicel MQC-1821 Manual

The text of page 1, from the PDF itself

E-One Moli Energy (Canada) Limited 20,000 Stewart Crescent Maple Ridge, B.C. Canada V2X9E7 PH: (604) 466-6654 FAX: (604) 466-6600 www.molienergy.com

R

MQC-1821B Li-ion Charger

Operating Instructions

Page 2 of Molicel MQC-1821 Manual

The text of page 2, from the PDF itself

FeaturesCharging Batteries• • • • • •• •

Fully Automatic Charge status indicator. Lightweight and small. Desktop unit. Safely charges Molicel MCR1821 Lithium-ion battery packs. Typical charging time, 4-5 hours (MCR1821J).

Powering the Charger

The charger unit should only be powered by the AC adapter supplied with the unit. The rating for the AC adapter is 9 Volt, 700 mA. Simply plug the AC adapter into a standard wall outlet. Plug the output plug of the AC adapter into the back of the charger as identified on figure 1. When power is correctly applied, the status indicator will be green.

The operation of the charger is fully automatic. Simply place the battery pack into the charger pocket as displayed in figure 1. Ensure that the two gold contacts on the pack are placed face down into the charger pocket. The status indicator will change to red to indicate that the charger is charging the battery. When the battery is fully charged, the status indicator will be green. The status indicator flashing indicates the operating temperature is out of range.

Safety Cautions

Only use the charger for charging Molicel, MCR-1821 lithium-ion rechargeable battery packs. Although the charger may become warm during charging, this is normal and presents no danger. Do not cover the vents holes in the back of the charger. For indoors use only. Do not operate around sources of moisture. Not recommended for use with Molicel, MCR-1821C batteries.

SpecificationsFigure 1

Input requirements
9.2 – 12 VDC @ 600 mA min.
Charge output
8.4 VDC @ 550 mA max.
Battery type supported
MCR-1821 Molicel
Short circuit protection
Built-in protection against accidental shorting of output contacts
Operating Temperature
10°C (50°F) to 45°C (112°F)
Weight
75g
External Dimension
69 mm (W) x 46 mm (H) x 61 mm (T)
Approvals
Charger CE Adapter UL, ULC