PenWare 1500 Product Reference Guide, pages 23 to 28

Pages 23 to 28 of 34: Chapter 3 Initializing the PenWare 1500; Chapter 4 Maintaining the PenWare 1500

The original document is the PDF (684 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the MobiNetix PW-1500

Page 23

Chapter 3 Initializing the PenWare 1500 Use the PenWare Initialization Program (PWINIT) on the PenWare Utilities Diskette v4.3 shipped with the terminal to configure the PenWare 1500. To install and run the PenWare Initialization Program: 1. Insert the PenWare Utilities Diskette in the disk drive (usually drive A or B) on the host computer. 2. Select Run from the Start menu. 3. Select Browse and locate the diskette drive. 4. Double-click on Setup. 5. Click OK. 6. Select Yes to launch the PenWare Initialization Program (PWINIT). 7. Click on Finish. 8. Perform the functions described in the following sections (calibrating the PenWare 1500 screen and setting LCD Clear Time) using PenWare Initialization Program.

3-1

Page 24

PenWare 1500 Product Reference Guide

Calibrating the PenWare 1500 To calibrate the touchscreen: 1. On the host computer, click the Start button within the PenWare Initialization Program. A cross hair appears on the PenWare 1500 screen. 2. Tap the center of the cross hair in the upper-left corner of the screen, then again in the lower-right corner. 3. Click OK on the host computer to return to the main PenWare Initialization Program screen.

Setting LCD Clear Time LCD Clear Time clears the PenWare 1500 screen after a specified amount of time has elapsed with no device activity. For example, set the LCD Clear Time to 30 to clear the PenWare 1500 screen after 30 seconds of inactivity. To set the clear time: 1. On the host computer, click LCD CLEAR TIME within the PenWare Initialization Program. 2. Enter the number of seconds. 3. Click SET.

3-2

Page 25

Chapter 4 Maintaining the PenWare 1500 Cleaning the PenWare 1500 Use a soft cotton cloth lightly dampened with isopropyl alcohol to remove any ink, fingerprint smudges, and dirt.

Diagnostics To perform power-on diagnostics: 1. Power up the PenWare 1500. The green LED flashes. 2. Touch the screen to invoke self-test mode. The green LED turns off, and the red LED turns on. 3. The LCD displays all pixels. Note: Any communication activity aborts diagnostic mode and returns the PenWare 1500 to idle mode to wait for a host command.

4-1

Page 26

PenWare 1500 Product Reference Guide

4-2

Page 27

Appendix A Technical Specifications

Table A-1. PenWare 1500 Technical Specifications Item

Description

Physical Characteristics Dimensions

6.0 in. L x 7.6 in. W x 1.5 in. H 152.4 mm L x 193.04 mm W x 38.1 mm H

Weight

16 oz/0.5 kg

Display

Monochrome backlit LCD

LCD Size

2.5 in. L x 1.3 in. W/63.5 mm L x 33.0 mm W

LCD Resolution

160 Hori. x 65 Ver. pixels

Touchpad

Resistive, pressure sensitive

Touchpad Resolution

418 Hori. X 798 Ver. dpi

Characters Per Line

26

Power Requirements

200 mA @ 9V DC unregulated

Power Source

9V AC adapter; European and host-powered options available; PS/2 power cable option

Terminal Interface

One RS-232 port (baud rate 9600); one RS-232 passthrough (RJ45 or HDB15 serial port)

A-1

Page 28

PenWare 1500 Product Reference Guide

Table A-1. PenWare 1500 Technical Specifications (continued) Item

Description

Peripherals and Accessories posBuilder Software Development Toolkit

Operating systems supported: DOS, Windows 3.x/95/98 and NT 3.51 or higher, IBM 4680/4690 Formats supported: BMP, SIG, DIB, CGM, EPS, PCL, TIFF, TXT, NLC, WMF, PCX and PLC Object tools: Support for VBX, ActiveX and OPOS, Onboard compression 7:1 standard (decompression required at host)

Regulatory Electrical Safety

UL and CE

EMI/RFI

FCC Class A

A-2