Page 21

Mounting and Wiring the Vision HAWK Smart Camera Important: Pin 9 (Host RxD) must be tied to ground (Pin 7) when using a flying lead cable and the serial port is not being used. The camera may not boot to completion if RxD is not grounded. Isolate unused wires. The ends of unused wires must not touch each other. • Mount the camera (1) securely as required by the application. 1

Mounting holes

• • • • •

Connect the Ethernet cable (2) from “B” on the camera (1) to the network. Connect the power supply cable (3) to “3” on the QX-1 (4). Connect the trigger (5) to “T” on the QX-1 (4). Connect the “Common” cable (6) from “A” on the camera (1) to “2” on the QX-1 (4). Plug in the power supply (3). 1

1

2

6

4

3

2

6

For most C-Mount lenses: • Loosen all lens screws to allow free lens movement. • Install first set screw in the available slot. • Remove one lens screw and install second set screw to allow for adjustment. Important: Configuration details may vary by lens model.

4

5

Standard Vision HAWK Vision HAWK Smart Camera Guide

3

5

Vision HAWK C-Mount 2-9

2 System Components

Mounting and Wiring the Vision HAWK Smart Camera

Page 22

Chapter

2

System Components

Optoisolated Outputs The reader has optoisolated outputs that can transfer signals from the camera to peripherals. Outputs can be configured as either NPN or PNP, but NPN and PNP cannot be mixed in a system, because the output common is shared by all outputs.

NPN Output for Host Input

2-10

Vision HAWK Smart Camera Guide

Page 23

NPN Output for External Load

Vision HAWK Smart Camera Guide

2 System Components

Mounting and Wiring the Vision HAWK Smart Camera

2-11

Page 24 read from a scan by OCR; it may hold reading errors

Chapter System Components

PNP Output for Host Input

Host Camera

Output 1 Aoute

=

Output 2

~. & us Sf, q Input - - _ - > +H Output Common > - $), - “ GND

2-12 Vision HAWK Smart Camera Guide

Page 25

PNP Output for External Load

Vision HAWK Smart Camera Guide

2 System Components

Mounting and Wiring the Vision HAWK Smart Camera

2-13

Page 26

Chapter

2

System Components

Optoisolated Inputs All discrete inputs are optoisolated. Inputs can be configured as either NPN or PNP, but NPN and PNP cannot be mixed in a system, because the input common is shared by all inputs.

NPN

2-14

Vision HAWK Smart Camera Guide

Page 27

PNP

Vision HAWK Smart Camera Guide

2 System Components

Mounting and Wiring the Vision HAWK Smart Camera

2-15

Page 28 read from a scan by OCR; it may hold reading errors

Chapter System Components

Input/Output Wiring

M12 12-pin plug flying lead cordset

Terminal Strip PLC

‘

Output1 Pin 5 Gray oe PASS/FAIL Output 2 Pin 11 Gray/Pink ® DATA READY Output3 Pin6 Pink a OPTIONAL 24V+ Pin2 oo 24V+ Input Common Pin 8 Red Trigger Pin 1 White ®

Output Common Pin 12

Ground Pin7

® Input 2, - Blue

Vision HAWK Smart Camera Guide

Page 29

Ground and Shield Considerations Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.

Vision HAWK

An earth ground is provided through the cable shields and chassis of the imager.

Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, imager, and their power supplies are connected to a common earth ground.

Vision HAWK Smart Camera Guide

2-17

2 System Components

Ground and Shield Considerations

Page 30

Chapter

2

System Components

Expected Power and Ground Connections for Proper Operation

Grounding Notes:

2-18

•

Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”.

•

Supply “Return” and “Earth” ground must be stable, low-impedance reference points.

•

“2-Terminal Power Supply” must still provide an “Earth” connection to the imager.

•

“Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.

Vision HAWK Smart Camera Guide