Each line names its page in the PDF.

A two-page Microscan configuration and quick start guide (P/N 83-126800-02 Rev R, 2015) for the Vision HAWK smart camera, in standard and C-Mount versions. It walks through checking the hardware, wiring through the QX-1 interface device, installing AutoVISION and building a first inspection job, and lists power figures, connectors, accessory part numbers and the part-number format.

Device
Smart camera for machine vision, with integrated high-output LED lighting on the non-C-Mount version, set up with AutoVISION software p. 1
Connectors
Connector A: serial M12 12-pin plug; connector B: Ethernet M12 8-pin socket p. 2
Power, standard
5-28VDC, 200mV p-p max ripple; CCD SXGA 170mA at 24VDC (typ.), 15.5 watts (max.); CMOS SXGA 135mA, 13 watts (max.) p. 2
Power, C-Mount
5-28VDC; CCD SXGA 130mA, 7 watts (max.); CMOS WVGA 105mA, 4 watts (max.); CMOS WUXGA 140mA, 5.7 watts (max.), currents at 24VDC (typ.) p. 2
Default IP address
192.168.0.10; set the PC to the same subnet, such as 192.168.0.100 p. 1
Part number format
GMV-6800-CLSYG: Comm 1 = Ethernet; Lens 0 = C-Mount, 2 = 30°, 3 = 45°, 4 = 12°, 5 = 15°; G = RoHS-compliant p. 2
Sensor codes
0 = CCD (SXGA), 1 = CMOS (WVGA), 2 = CCD (SXGA) Color, 3 = CMOS (WUXGA) p. 2
Software codes
0 = AV, 2 = AV + VS, 4 = AV + Ver/OCV, 6 = AV + VS + Ver/OCV p. 2
Positioning
Focal distance of one inch or more; maximum skew ±30°, maximum pitch ±30° p. 1
Lens kits
12° 98-000147-04, 15° 98-000147-01, 30° 98-000147-02, 45° 98-000147-03 p. 2
Accessories
Adapter Plate Kit 98-000143-01; Right Angle Mirror Kit 98-000144-01; Window Replacement 98-000146-01; L-Bracket Kit 98-000148-01; Infrared (IR) Filter 98-000205-01; Glass Window Kit 98-000206-01 p. 2
Kits and software
Demo Kit, Vision HAWK 98-000215-01; AutoVISION to Visionscape Upgrade 98-000217-01; Microscan Tools Drive 37-000010-01 p. 2
PC requirements
Intel Core 2 Duo, 2GB RAM/128MB Video RAM (Windows 7), 750MB hard drive space, Internet Explorer 7 or higher p. 1
QX-1 interface device
Connectors 1 and 3 are 12-pin plugs, connector 2 a 12-pin socket, T a 4-pin trigger socket; two switches route signals p. 2

What this manual walks you through

  • Mounting and positioning the camera to avoid glare p. 1
  • Fitting a C-Mount lens with set screws p. 1
  • Wiring Ethernet, power and trigger through the QX-1 p. 1
  • Installing AutoVISION and connecting to the camera p. 1
  • Evaluating a captured image and running Auto Calibration p. 1
  • Setting trigger, exposure, gain, focus and lighting p. 2
  • Adding Decode and OCR tools to a first job p. 2
  • Trying out and running the job on the camera p. 2

Good to know

  • Pins 9 and 7 of connector A must be tied to ground when a flying lead cable is used without the serial port. p. 2
  • Integrated lighting is only on the non-C-Mount version; some applications may need external lighting. p. 1
  • C-Mount lens setup details may vary by lens model. p. 1

Questions this manual answers

What is the default IP address of the Vision HAWK?

192.168.0.10. The guide says to set the PC to the same subnet, for example 192.168.0.100. p. 1

What voltage does the Microscan Vision HAWK need?

5-28VDC with 200mV p-p maximum ripple; maximum power ranges from 4 watts (C-Mount CMOS WVGA) to 15.5 watts (standard CCD SXGA). p. 2

What software sets up the Vision HAWK camera?

AutoVISION, on the Microscan Tools Drive packed with the camera or from the Download Center at www.microscan.com. p. 1

How do I read a Vision HAWK part number?

It follows GMV-6800-CLSYG, where the digits give the communications, lens, sensor and software options and G means RoHS-compliant. p. 2

The file

Size and text

Pages2
PDF2.2 MB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan Vision Hawk Quick Start Guide

The text of page 1, from the PDF itself

Configuration and Quick Start Guide

Vision HAWK Smart Camera

P/N 83-126800-02 Rev R

Copyright ©2015 Microscan Systems, Inc.

Step 6, Evaluate a Captured Image and Auto Calibrate

Step 3, Mount and Position the Camera 1. Position the camera at a focal distance of one inch or more from a test object. 2. Tip the camera relative to the object to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the camera as shown. Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. Proper lighting is critical to the success of a machine vision application. The Vision HAWK features integrated high-output LED lighting (non-C-Mount version only). Depending on the requirements of your application, you may also need to add external lighting from Microscan’s NERLITE family of machine vision lighting products. Consider the following:

  • Is the surface of the object flat, slightly bumpy, or very bumpy?
  • Is the surface matte or shiny?
  • Is the object curved or flat?
  • What is the color of the object or area being inspected?
  • Is the object moving or stationary? Machine vision lighting should maximize contrast of the areas or features being inspected while minimizing the contrast of everything else. For most C-Mount lenses:
  • Loosen all lens screws to allow free lens movement.
  • Install first set screw in the available slot.
  • Remove one lens screw and install second set screw to allow for adjustment. Important: Configuration details may vary by lens Camera / Object Positioning Camera / Object Positioning model. (Standard Vision HAWK) (Vision HAWK C-Mount)

Step 4, Install AutoVISION

Step 1, Check Hardware

You will see the Image view after selecting your device. This view allows you to evaluate your first image capture, providing information such as image size and a histogram. Click the Auto Calibration button to set optimal camera parameters automatically. You can also adjust Exposure, Gain, and Focus as needed, and set the desired Lighting Mode.

Step 7, Create Your First Job with AutoVISION After you have evaluated a captured image and Auto Calibrated the camera in the Image view, you will move to the Edit view. This interface allows you to set camera parameters, add machine vision tools to captured images, set tool parameters, and configure I/O inspection outputs.

AutoVISION can be found on the Microscan Tools Drive that is packaged with the camera.

The list of hardware below can be used in a variety of applications and configurations. Consult with Microscan for further information about which items are most appropriate for your application. Item 1 2 3 4 5 6 7 8 9

Description Vision HAWK Smart Camera QX-1 Interface Device Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m Cordset, Host, Serial, M12 12-pin Plug to DB9, 1 m Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m Power Supply, M12 12-pin Socket, 1.3 m Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m Trigger, M12 4-pin Plug, NPN, Dark On, 2 m Cordset, C-Mount-to-Smart Series Light (not shown)

Part Number GMV-6800-XXXXG 98-000103-02 61-000162-01 61-000152-01 61-000153-01 97-000012-01 61-000160-03 99-000020-02 61-000207-01

Note: Additional cordsets available in the Microscan Product Pricing Catalog.

Step 2, Connect the System 1

1

1. Follow the prompts to install AutoVISION from the Tools Drive. 2. Click on the AutoVISION icon to run the program. Note: AutoVISION can also be installed from the Download Center at www.microscan.com. Minimum System Requirements

  • Intel Core 2 Duo Processor
  • Internet Explorer 7 or higher
  • 2GB RAM/128MB Video RAM (Windows 7)
  • 750MB hard drive space
  • 16-bit color display
  • 3.0 Windows Experience Index

Step 8, Explore the Interface The Edit view features a large image area with tool icons above and tool parameters below or to the right depending on user preference. When a tool is selected, its specific parameters appear. Tools that have been added are shown in the job list to the left of the image area, below Camera. Image settings can be controlled using the icons in the corners of the image area.

Step 5, Connect to the Camera 3

722 6378

Ethernet Configuration (Standard Vision HAWK)

6

After you launch AutoVISION, you will see the Select a device to start editing a job view. Note: If there is a default job on the camera, AutoVISION will automatically skip the Connect step and you will see the Image view. 1. Select your camera from the Select Device dropdown menu. 2. Click the Modify button beneath the camera settings details to change camera settings. 3. Choose whether you want to create a new job, load a job (.avp), or upload a job from the camera.

8

Ethernet Configuration (Vision HAWK C-Mount)

1. Mount the camera (1) as required by the application. 2. Connect the Ethernet Cordset (7) from “B” on the camera (1) to the network. 3. Connect the power supply (6) to “3” on the QX-1 (2). 4. Connect the trigger (8) to “T” on the QX-1 (2). 5. Connect the “Common” Cordset (3) to “2” on the QX-1 and “A” on the camera. 6. Plug in the power supply (6).

Note: The Vision HAWK’s default IP address is: 192.168.0.10. Set your PC to the same subnet (192.168.0.100, for example).

Page 2 of Microscan Vision Hawk Quick Start Guide

The text of page 2, from the PDF itself

Step 9, Set Camera Parameters

Step 12, Run the Job

1. Click on the Camera box to the left of the image area. 2. In the camera parameters below the image area, select the desired type of Trigger, Trigger Polarity, Photometry (Exposure and Gain), Focus, and Lighting.

When all job parameters are set, click on the Run step at the top of the interface. The software will download the vision job just created to the camera and will begin the inspection. Inspection results and the list of active tools are shown at the right of the image view. That information can also be moved below the image area by clicking the orientation buttons above the inspection results area.

Power Requirements and Pin Assignments Standard, CCD, SXGA: 5-28VDC, 200mV p-p max ripple, 170mA at 24VDC (typ.), 15.5 watts (max.) Standard, CMOS, SXGA: 5-28VDC, 200mV p-p max ripple, 135mA at 24VDC (typ.), 13 watts (max.) C-Mount, CCD, SXGA: 5-28VDC, 200mV p-p max ripple, 130mA at 24VDC (typ.), 7 watts (max.) C-Mount, CMOS, WVGA: 5-28VDC, 200mV p-p max ripple, 105mA at 24VDC (typ.), 4 watts (max.) C-Mount, CMOS, WUXGA: 5-28VDC, 200mV p-p max ripple, 140mA at 24VDC (typ.), 5.7 watts (max.) Output 2 Default

Input 1PowerOutput 1Host TxDOutput 3

Trigger Ground Host RxD

Input Common Output Common

A (Serial) M12 12-pin Plug

Connector A on the back of the camera is a serial M12 12-pin plug. Important: Tie pins 9 and 7 to Ground if you are using a flying lead cable and not using the serial port.

TerminatedTX (+)TerminatedRX (–)

RX (+) Terminated TX (–) Terminated

Connector B on the back of the camera is an Ethernet M12 8-pin socket.

B (Ethernet) M12 8-pin Socket

QX-1 Interface Device

Step 10, Add Tools to the Job

Test Jobs

1. Click on the Decode Tool or drag it onto the image area. 2. Use the anchor points at the corners of the region of interest to form a box around the Data Matrix symbol. Leave plenty of space on each side of the symbol. 3. Now add a second Decode Tool and do the same for the 1D symbol below the Data Matrix symbol. 4. Finally, add an OCR Tool and drag the region of interest around the area of the image where “123456” is printed.

Note: For descriptions of more advanced functionality, such as setting Inspection Outputs or using the Locate Tool and Decode Tool’s Dynamic Locate functionality to track multiple tools from image to image, see the help documentation in AutoVISION software.

Connector T on the QX-1 Interface Device is the trigger connector. Connectors 1 and 3 are 12-pin plugs, and Connector 2 is a 12-pin socket. All three connectors can be assigned to bus power and data as required by the application. The two switches at the center of the device allow the user to route signals as needed. This simple diagram (shown on the base of the QX-1) illustrates how power, communications, I/O, and trigger signal can be routed through the QX-1 device depending on the needs of the application. The switches greatly increase signal routing flexibility.

P

Decode Tool, OCR Tool, Match Strings Tool, String Format Tool LOT 123456 DATE 05/2012 VISION SIMPLIFIED

T

QX-1 Interface Device

QX-1 Communications I/O - Power - Trigger

TriggerGround+10-28V

Trigger/New Master / Input 1 Common

Measure Tool, Count Tool

QX-1 Trigger Connector 4-pin Socket

Vision HAWK Accessories

Step 11, Try Out the Job Once you have configured the tools as desired, use the arrow icons in the Job area to try the job you have just created. Note: Most jobs will inspect multiple captured images. If only one image is being inspected, the effect of the arrow icons will not be evident.

Measure: Measure the distance between the jaws of the caliper gauges at left.

Try Out Job Once Try Out Job in Loop

Count: Count the circles on the dice shown at right.

AutoVISION to Visionscape Upgrade 98-000217-01 Adapter Plate Kit 98-000143-01 Right Angle Mirror Kit 98-000144-01 Window Replacement 98-000146-01 12° Lens Kit 98-000147-04 15° Lens Kit 98-000147-01 30° Lens Kit 98-000147-02 45° Lens Kit 98-000147-03 L-Bracket Kit 98-000148-01 Infrared (IR) Filter 98-000205-01 Glass Window Kit 98-000206-01 L-Bracket Kit, QX Series 98-000148-01 Demo Kit, Vision HAWK 98-000215-01 Microscan Tools Drive 37-000010-01 Note: Additional accessories are available in the Microscan Product Pricing Catalog. See the Vision Hawk Smart Camera Guide for Vision Hawk C-Mount accessories.

Vision HAWK Part Numbers

Copyright ©2015 Microscan Systems, Inc.

Vision HAWK part numbers follow the format GMV-6800-CLSYG: Comm = 1 for Ethernet; Lens = 0 for C-Mount, 2 for 30°, 3 for 45°, 4 for 12°, 5 for 15°; Sensor = 0 for CCD (SXGA), 1 for CMOS (WVGA), 2 for CCD (SXGA) Color, 3 for CMOS (WUXGA); Y (Software) = 0 for AV, 2 for AV + VS, 4 for AV + Ver/OCV, 6 for AV + VS + Ver/OCV G = RoHS-Compliant