The text of a manual · part 34 of 37
MS-4 Imager User Manual, pages 331 to 340
Pages 331 to 340 of 366
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-4
Page 331
Output Format
Ordered Output Filter Definition:
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.
Serial Cmd:
<K745,number of filters>
Default:
0
Options:
0 to 10
MS-4 Imager User Manual
14-13
Page 332
Ordered Output Filter
14-14
MS-4 Imager User Manual
Page 333
Appendices Contents Appendix A General Specifications .............................................................................................. A-2 Appendix B Electrical Specifications ............................................................................................ A-5 Appendix C Serial Configuration Commands............................................................................... A-6 Appendix D Communications Protocol....................................................................................... A-12 Appendix E ASCII Table............................................................................................................. A-21 Appendix F Interface Standards................................................................................................. A-22 Appendix G Object Detector....................................................................................................... A-23 Appendix H Operational Tips ..................................................................................................... A-24 Appendix I USB-to-Serial Virtual COM Port Driver..................................................................... A-25 Appendix J Glossary of Terms ................................................................................................... A-28
MS-4 Imager User Manual
A-1
Page 334
General Specifications
Appendix A, General Specifications Mechanical Height: 1" (25.4 mm) Width: 1.8" (45.7 mm) Depth: 2.10" (53.3 mm) Weight: 2 oz. (57 g)
Environmental Enclosure: IP54, category 2 Operating Tempurature: 0° to 40°C (32° to 104°F) Storage Tempurature: -50° to 75° C (-58 to 167°F) Humidity: up to 90% (non-condensing)
Electrical Power: 3 Watts (max.) (USB: 2.5 Watts max.) 5 VDC +/– 5 %, 200 mV p-p max. ripple, 394mA @ 5 VDC (typ.) (USB: 300mA @ 5VDC) Optional I/O: Optoisolated (with IC-332)
CE Mark General Immunity for Light Industry: EN 55024: 1998 ITE Immunity Standard Radiated and Conducted Emissions of ITE Equipment: EN 55022:98 ITE Disturbances
Light Source Type: High output LEDs.
Light Collection Options Progressive scan, square pixel. Software adjustable shutter speed, electronic shutter. VGA: 640 by 480 pixels.
Connector
Note: Nominal dimensions shown. Typical tolerances apply.
MS-4 Imager Dimensions
Type: 3 ft. cable terminated with High Density 15-pin D-Sub socket or USB type A connector.
Indicators LEDS: Read Performance, Power, Read Status. Green Flash: Good read. Blue Target Pattern: Symbol locator. Beeper: Good read, match/mismatch, No Read, serial command confirmation, on/off.
Discrete I/O Trigger Input: 5 to 28V rated (0.16 mA @ 5VDC) New Master: 5 to 28V rated (0.16 mA @ 5VDC) Default: 3.3V rated (0mA at 3.3V) Outputs (1, 2, 3): 5V TTL compatible, can sink 10 mA and source 10mA. Optional I/O: Optoisolated (with IC-332 accessory)
Communication Protocols Standard Interface: RS-232, RS-422, or USB.
Symbology Types 2D Symbologies: Data Matrix (ECC 0-200), QR Code. Stacked Symbologies: PDF417, MicroPDF417, GS1 DataBar (Composite & Stacked). Linear Symbologies: Code 39, Code 128, BC412, Interleaved 2 of 5, UPC/EAN, Codabar, Code 93.
Read Parameters Pitch: ±30° Skew: ±30° Tilt: 360° Decode Rate: Up to 10 decodes per second.
A-2
MS-4 Imager User Manual
Page 335
Appendices Read Ranges Low Density in.
mm
6
152
5
127
4
102
3
76
2
51
1
25
Standard Density (inches/mm) 20 mil 2D | 15 mil 1D 15 mil 2D | 10 mil 1D
10 mil 2D | 7.5 mil 1D
51
25
0 3
2
25 1
1
51
76 mm
2
3 in.
Distance
Distance
Standard Density
Low Density (inches/mm)
in.
mm
7
178
6
152
30 mil 2D | 20 mil 1D 20 mil 2D | 15 mil 1D
5
127
4
102
3
76
2
51
1
25
15 mil 2D | 10 mil 1D
76
51
25
25
51
76
102 mm
3
2
1
1
2
3
4
0 4 Wide Axis (H = 3/4 W)
in.
Wide Axis (H = 3/4 W)
Narrow-bar-width 1D
Field of View 2D
(maximum)
Read Range
Standard Density .0075" (0.19 mm)
.010" (.25 mm)
2.4” (61 mm)
.010" (0.25 mm)
.015" (.38 mm)
2.6” (66 mm)
1.8 to 4.2" (46 mm to 107 mm) 1.6 to 4.7" (41 mm to 119 mm)
.015"(0.38 mm)
.020 (.51 mm)
2.8” (71 mm)
1.4 to 5.2" (36 mm to 132 mm)
.010" (0.25 mm)
.015" (.38 mm)
4.2" (107 mm)
3.0 to 4.5" (76 mm to 114 mm)
.015" (0.38 mm)
.020” (.51 mm)
5.0” (127 mm)
2.5 to 5.5” (64 mm to 140 mm)
.020" (0.51 mm)
.030” (.76 mm)
5.8” (147 mm)
2.0 to 6.8” (51 mm to 173 mm)
Low Density
MS-4 Imager User Manual
A-3
Page 336
General Specifications Safety Certifications FCC, UL/cUL, CE, CB, RoHS/WEEE Compliance
©2015 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.
A-4
MS-4 Imager User Manual
Page 337
Appendices
Appendix B, Electrical Specifications Power: 3 Watts (max.) (USB: 2.5 Watts max.) 5 VDC +/– 5 %, 200 mV p-p max. ripple, 394mA @ 5 VDC (typ.) (USB: 300mA @ 5VDC) Optional I/O: Optoisolated (with IC-332 accessory)
Host Connector / Pin Assignments High Density 15 Pin D-sub Socket Connector Pin
Host RS-232
1
Host RS-422/485
In/Out
TxD
TxD(–)
Out
RxD
RxD(–)
In
Power +5 VDC
2
TxD
3
RxD
4
In
Power/Signal Ground
5 6
Host/Aux RS-232
NC RTS
Aux TxD
TxD(+)
Out
7
Output 1 TTL a
8
Default configuration b
In
9
Trigger
In
10
CTS
Aux RxD
Out
RxD (+)
In
11
Output 3 TTL a
Out In
12
New Master (NPN)
13
Chassis ground c
14
Output 2 TTL a
15
NC
Out a. Can sink 10 mA and source 10 mA. b. The default is activated by connecting pin 8 to ground pin 4. c. Chassis ground: Used to connect chassis body to earthground only. Not to be used as power or signal return.
MS-4 Imager User Manual
A-5
Page 338
Serial Configuration Commands
Appendix C, Serial Configuration Commands Communications Host Port Connections Auxiliary Port Connections RS-422 Status Host Port Protocol Preamble Postamble Response Timeout LRC Auxiliary Port System Data Status ACK/NAK Options Polling Mode Options USB HID Reports Autoconfiguration Daisy Chain Calibration Calibration Options Autocalibrate Read Cycle Trigger Mode/Duration Serial Trigger Character External Trigger State End of Read Cycle Minimum Good Reads Multisymbol Start Trigger Character Stop Trigger Character Capture Mode Capture Timing Image Storage IP Timeout Symbologies Narrow Margins/Symbology ID Background Color Composite Code 39
A-6
<K100,baud rate,parity,stop bits,data bits> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> <K102,status> <K140,protocol,address> <K141,status,preamble characters> <K142,status,postamble characters> <K143,response timeout> <K145,status> <K146,aux status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K149,Microscan HID IN report status,keyboard IN report status> <K150DAISY> <K529,gain,shutter speed,focus position,symbol type,WOI framing, WOI margin,line scan height> <@CAL> <K200,trigger mode,trigger filter duration> <K201,serial trigger character> <K202,external trigger state> <K220,end of read cycle,read cycle timeout> <K221,minimum good reads> <K222,number of symbols,multisymbol separator> <K229,start character> <K230,stop character> <K241,capture mode,number of captures,rapid capture mode> <K242,time before first capture,time between first and second captures,,,,,,,,time between seventh and eighth captures> <K244,image storage type,image store mode> <K245,image processing timeout> <K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set>
MS-4 Imager User Manual
Page 339
Appendices Codabar Interleaved 2 of 5 UPC/EAN Code 128/EAN 128
Code 93 PDF417 Data Matrix QR Code BC412 DataBar-14 DataBar Limited DataBar Expanded MicroPDF417 I/O Parameters Power On/Reset Counts Time Since Reset Service Message Serial Verification Beeper Quality Output Symbol Data Output Read Duration Output No Read Message Bad Symbol Message No Symbol Message 1D/Stacked Symbology Qualification 2D Symbology Qualification
Frame Information LED Configuration Image Output MS-4 Imager User Manual
<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> <K472,status,check digit status,check digit output status,symbol length #1, symbol length #2, guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status, separator character,supplemental type,format UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> <K475,status,fixed symbol length status,symbol length> <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> <K479,ECC 200 status, ECC 000 status,ECC 050 status, ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> <K480,status> <K481,status,check digit output,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,[unused],fixed symbol length status,fixed symbol length> <K406,power-on,resets,power-on saves,power-on flash saves> <K407,hours,minutes> <K409,status,service message,threshold,resolution> <K701,serial command echo status,serial command beep status, control/hex output> <K702,status> <K704,decodes/trigger separator,decodes/trigger status> <K705,symbol data output status,when to output> <K706,status,separator> <K714,status,message> <K715,[unused],message> <K716,[unused],message> <K717,minimum number of bars,minimum number of qualified scan lines,start/stop status> <K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension status,dimension 1,dimension 2,dimension tolerance,orientation status,orientation value> <K734,output frame number,output coordinates> <K737,LED mode,ISO/IEC 16022 grade> <K739,image output mode,communication port,file format,jpeg quality>
A-7
Page 340
Serial Configuration Commands Target/Flood LEDs
<K750,green flash LED status,target pattern LED status,green flash duration> Database Identifier Output <K759,status,separator> EZ Button <K770,global status,default on power-on,load configuration database, save for power-on> EZ Button Modes <K771,single beep,two beeps,three beeps,four beeps> Trend Analysis Output 1 <K780,trend analysis mode,trigger evaluation period,number to output on> Trend Analysis Output 2 <K781,trend analysis mode,trigger evaluation period,number to output on> Trend Analysis Output 3 <K782,trend analysis mode,trigger evaluation period,number to output on> Diagnostic Output 1 <K790,unused 1,servuce unit> Diagnostic Output 2 <K791,unused 1,servuce unit> Diagnostic Output 3 <K792,unused 1,servuce unit> ISO/IEC 16022 Symbol Quality Output 1 <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, axial non-uniformity threshold,output on UEC,UEC threshold> ISO/IEC 16022 Symbol Quality Output 2 <K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, axial non-uniformity threshold,output on UEC,UEC threshold> ISO/IEC 16022 Symbol Quality Output 3 <K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity, axial non-uniformity threshold,output on UEC,UEC threshold> Configurable Output 1 <K810,output on,output state,pulse width,output mode> Configurable Output 2 <K811,output on,output state,pulse width,output mode> Configurable Output 3 <K812,output on,output state,pulse width,output mode> Symbol Quality Symbol Quality Separator/ Data Matrix <K708,symbol quality separator,data matrix output mode> Output Mode ISO/IEC 16022 Symbol Quality Output <K709,symbol contrast,print growth,axial non-uniformity,UEC> Microscan Symbol Quality Output <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone> Static Validation Report <VAL> Matchcode Matchcode Type <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Number of Master Symbols <K224,number of master symbols> New Master Pin <K225,status> Enter Master Symbol Data <K231,master symbol number,master symbol data> Request Master Symbol Data <K231?,>[for all] or <K231?,master symbol number> Delete Master Symbol Data <K231,master symbol number,> Match Replace <K735,status,match replacement string> Mismatch Replace <K736,status,mismatch replacement string>
A-8
MS-4 Imager User Manual