Page 211

I/O Parameters

Object Info Output Definition: Serial Cmd: Default: Options:

If a symbol is decoded during an image capture, the symbol type and other supplementary symbol information is also included. <K757,comm port,image mode,image format,jpeg quality,object info output, grade output> Disabled 0 = Disabled 1 = Enabled

Grade Output Definition: Serial Cmd: Default: Options:

Symbol quality information will be output in the form of an abbreviated identifier for each read cycle. <K757,comm port,image mode,image format,jpeg quality,object info output, grade output> Disabled 0 = Disabled 1 = Enabled

MS-4 Imager User Manual

7-55

Page 212

Configuring EZ Trax Output

7-56

MS-4 Imager User Manual

Page 213

8 Symbol Quality Contents Symbol Quality Serial Commands ................................................................................................ 8-2 Overview of Symbol Quality.......................................................................................................... 8-3 Symbol Quality by ESP................................................................................................................. 8-4 Symbol Quality Separator / Data Matrix Output Mode.................................................................. 8-8 ISO/IEC 16022 Symbol Quality Output....................................................................................... 8-10 ISO/IEC 16022 Symbol Quality Output by ESP.......................................................................... 8-12 Microscan Symbol Quality Output .............................................................................................. 8-13 Microscan Symbol Quality Output by ESP ................................................................................. 8-16

This section describes parameters that, when enabled, will output detailed symbol quality evaluations.

MS-4 Imager User Manual

8-1

Page 214

Symbol Quality Serial Commands

Symbol Quality Serial Commands Symbol Quality Separator/ Data <K708,symbol quality separator,Data Matrix output mode> Matrix Output Mode ISO/IEC 16022 Symbol Quality <K709,symbol contrast,print growth,axial non-uniformity, Output UEC> Microscan Symbol Quality Output <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Static Validation Report <VAL>

8-2

MS-4 Imager User Manual

Page 215

Symbol Quality

Overview of Symbol Quality Information about symbol quality and timing can be appended to symbol data by enabling specific evaluation parameters. The order in which these values are appended corresponds directly to the order in which they appear in ESP‘s Symbol Quality tree control. Symbol Quality parameters are separated into ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output. Total Read Time, Symbol Quality Separator, and Output Mode are common to both ISO/IEC 16022 and Microscan Grading Parameters.

The enabled Symbol Quality parameters are appended to symbol data output in the order that they appear in the tree control.

If you enable the outputs shown above, they will be returned in this order: Symbol Data

Locate Time (Microscan Grading)

Symbol Contrast (ISO/IEC 16022)

Decode Time (Microscan Grading)

0123456789abcdefghijklmnopqrstuv 256 A 30 210 3 17 Total Read Time

Pixels Per Element (Microscan Grading)

Capture Time (Microscan Grading)

MS-4 Imager User Manual

8-3

Page 216

Symbol Quality by ESP

Symbol Quality by ESP Tree Control To open nested options, single-click the +. Click this button to bring up the App Mode view.

Click this button to bring up the Symbol Quality tree control.

To change a setting, double-click the setting and use your cursor to scroll through the options.

8-4

MS-4 Imager User Manual

Page 217

Symbol Quality

Report Tab

The Report tab allows the user to initiate Data Matrix Grading and to generate and save grading reports. To save the report as a PDF file, an HTML file, a CSV file, or an RTF file, click the Save Report button. Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons.

The Symbol Quality interface is divided into three sections: Report, Locate, and Preferences.

The imager’s field of view is shown here. When grading is completed, the initial report is also shown in this viewing area.

MS-4 Imager User Manual

8-5

Page 218

Locate Tab The Locate tab allows the user to determine the position of the symbol within the imager’s field of view, and to optimize the imager’s camera settings for symbol quality evaluation.

Click the Locate button to display the symbol in the imager’s field of view.

8-6

Click the Calibrate button to optimize camera settings.

MS-4 Imager User Manual

Page 219

Symbol Quality

Preferences Tab

The Preferences tab allows the user to set defaults that are automatically activated when grading is completed. For this reason, the user is advised to set preferences before performing grading.

This information is appended at the bottom of the report.

Choose the default report type to be generated when you click Save Report on the Report tab. Check Autofit Content to ensure that saved PDF report content will fit on a single page.

Typically you will be asked where you wish to store your report. If you do not want to be prompted to choose a file path, click Store Report without file path prompt.

Click the Include Image check box to output the captured symbol image with your saved report as a Bitmap or JPEG image file.

Enables ESP to parse UII symbol data into the correct fields and output order defined by the U.S. Department of Defense IUID initiative.

Returns all settings to default.

MS-4 Imager User Manual

Returns all settings to most recent.

8-7

Page 220

Symbol Quality Separator / Data Matrix Output Mode

Symbol Quality Separator / Data Matrix Output Mode Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol Quality Output and Microscan Symbol Quality Output.

Symbol Quality Separator Definition: Serial Cmd: Default: Options:

Inserts a separator between each enabled field of the symbol quality output. <K708,symbol quality separator,output mode> <SP> (space character) Any ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K708h,3C> For >: <K708h,3E> For , : <K708h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Symbol Quality Separator by ESP

When you double-click on the default separator SP, the Symbol Quality Separator Calculator appears. Use the calculator keypad for one-click separator configuration.

8-8

MS-4 Imager User Manual