The text of a manual · part 2 of 37
MS-4 Imager User Manual, pages 11 to 20
Pages 11 to 20 of 366
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-4
Page 11
Introduction
Statement of RoHS Compliance All Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF
Please contact your sales manager for a complete list of Microscan’s RoHS-Compliant products. This declaration is based upon information obtained from sources which Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.
MS-4 Imager User Manual xi
Page 12
Statement of RoHS Compliance xii
MS-4 Imager User Manual
Page 13
1 Quick Start Contents Step 1 Check Required Hardware ................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Imager and Symbol.............................................................................................. 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Select Communications Protocol....................................................................................... 1-7 Step 7 Locate the Symbol in the FOV........................................................................................... 1-8 Step 8 Calibrate Settings ........................................................................................................... 1-10 Step 9 Test Read Rate .............................................................................................................. 1-11 Step 10 Configure the Imager in ESP........................................................................................ 1-12 Step 11 Make Menu Changes and Save in ESP ....................................................................... 1-13
This section is designed to get your MS-4 Imager up and running quickly, using the EZ button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the Imager’s capabilities and to test sample symbols. Detailed setup information for installing the Imager into your actual application can be found in the subsequent chapters.
MS-4 Imager User Manual
1-1
Page 14
Check Required Hardware
Step 1, Check Required Hardware Item 1 2
Description MS-4 Imager IB-3PC
3
Power Supply
4
Comm. Cable
Part Number FIS-0004-XXXXG FIS-0001-0030G 97-000002-01 (90-264 VAC, +5VDC) 97-100004-15 (24VDC) 61-000010-02
To additional imagers or terminating resistor
1 To host
Hardware Required (RS-232 / RS-422)
Hardware Required (USB)
Caution: Be sure that all cables are connected BEFORE applying power to a system with an external power source (RS-232 / RS-422). Always power down BEFORE disconnecting any cables.
1-2
MS-4 Imager User Manual
Page 15
Quick Start
Step 2, Connect the System Connecting by RS-232 / RS-422
• Connect the Imager (1) to the IB-3PC interface (2). • Connect the comm. cable (4) to the host (5) and to the host connector on the IB-3PC (2). • Connect power supply (3) to the IB-3PC (2). • Apply power to the Imager.
Connecting by USB
• Plug the MS-4 Imager’s USB cable into a host USB port. The host will power the Imager.
To additional imagers or terminating resistor
1 To host
Hardware Configuration (RS-232 / RS-422)
Hardware Configuration (USB)
Caution: Be sure that all cables are connected BEFORE applying power to a system with an external power source (RS-232 / RS-422). Always power down BEFORE disconnecting any cables.
MS-4 Imager User Manual
1-3
Page 16
Position Imager and Symbol
Step 3, Position Imager and Symbol • Position the Imager at a distance from the symbol that matches the factory pre-set focal distance. For example, if your MS-4 is pre-set at 4”, position the Imager’s parting line 4” from the symbol. • Tip the Imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the Imager as shown. • Position the Imager in a place with as little ambient light as possible. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).
±30°
Imager Position Relative to Symbol • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads. • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. Note: For instant setup and validation, the MS-4 can be hand-held or placed on its side. For accuracy, however, Microscan’s mounting arm adapter kits (P/N 98-000048-01) are recommended.
1-4
MS-4 Imager User Manual
Page 17
Quick Start
Step 4, Install ESP Easy Setup Program (ESP) is Microscan’s proprietary setup and testing application. The purpose of ESP is to provide a quick and easy way to set up and configure Microscan readers. When the MS-4 is connected to a host computer (Windows Vista, XP, or 2000), ESP can be used to configure reader settings and to set up communications between the reader and host.
If installing from the Microscan Tools Drive: 1. Insert the Microscan Tools Drive into a USB port on your computer. 2. Select ESP Software from the navigation bar at the left of the screen. 3. Click on ESP Software under the Current Version heading. 4. Click the Run button and follow the prompts in the ESP Setup Wizard. Note: During installation, you may see an Internet Explorer Security Warning that states: “The publisher could not be verified.” If you see this warning, click Run to continue installation.
If downloading from the web:
1. Go to the Download Center at www.microscan.com. 2. Create a new member account or, if you are already a member, enter your user name and password. 3. Navigate to the “Microscan Software” section of the Download Center (near the top of the page). 4. Click on the link showing the latest version of ESP. Extract the ESP installation files to a location of your choice on the host computer. Note where your ESP.exe file is stored on your hard drive. 5. At the end of the installation process, the following icon will appear on your desktop:
6. Click the ESP icon to start the program.
System Requirements for ESP • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended)
MS-4 Imager User Manual
1-5
Page 18
Select Model
Step 5, Select Model When you start ESP, the following menu will appear:
1. Click the MS-4 button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this window at Startup”. 2. Select the default reader name (MS-4-1), or type a name of your choice in the Description text field and click OK. 3. Click Yes when this dialog appears:
Note: If you need to select another reader model later, click the Switch Model button near the top of the screen. 1-6
MS-4 Imager User Manual
Page 19
Quick Start
Step 6, Select Communications Protocol Important: The Imager is in Continuous Read Mode by default. For best connection results, be sure that no symbols are within the Imager’s field of view while attempting to connect. • When the Select Protocol dialog appears, choose your connection protocol and click Next.
If you choose USB protocol:
If you choose RS-232 protocol:
• Select the MS-4 from the Select Device menu and click Finish.
• Click Connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen. USB: RS-232: • If you are using an RS-232 interface and your connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the Imager’s settings, check the Force Connect box.
MS-4 Imager User Manual
1-7
Page 20
Locate the Symbol in the FOV
Step 7, Locate the Symbol in the FOV • Move the symbol or the Imager so that the blue target pattern is centered over the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V. It is important for the whole symbol to fall within the field of view (FOV) of the Imager. The field of view is what appears in ESP’s Locate/Calibrate window.
Center on object in field of view.
Target pattern shown as it would appear between 3 and 6 inches.
Locate by EZ Button If you are not connected to a host computer, the EZ button will allow you to locate a symbol in the Imager’s FOV. • Hold down the EZ button for about one second and release when you hear one short beep. The amber 20% LED will turn on, and you will see the blue target pattern projected from the front of the Imager. • Center the target pattern on the symbol. Note: To end all EZ button functions, press the EZ button once and quickly release.
1-8
MS-4 Imager User Manual