Output Format
Format Extract Output Index Definition:
Output Index refers to the database entry you wish to modify with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output you wish to build. Starting with index # 1, enter either an extract or insert command to begin building your desired output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until you are finished building the string.
Serial Cmd:
<K740,output index,start location,length>
Options:
1 to 100
Start Location Definition:
Defines the location within the symbol data where the character extraction will begin. The first character extracted will also be the first character in the sequence displayed in user-defined output.
Serial Cmd:
<K740,output index,start location,length>
Default:
0
Options:
1 to n (maximum number of characters in the symbol data).
Length Definition:
Defines the length (in consecutive characters) that will be extracted and placed in user-defined output.
Serial Cmd:
<K740,output index,start location,length>
Default:
0 (disabled; end of format cell array)
Options:
1 to n (maximum number of characters in the symbol data).
Quadrus MINI Velocity User’s Manual
14-5
Page 352
Format Assign
Format Extract by ESP
The Extract Range function corresponds to the Start Location and Length parameters in the Format Extract serial command.
You can extract and insert several character sequences using ESP’s Symbol Parse feature. In this example, the selected extraction range is characters 2-4. The “Sample Symbol” example on the Symbol Parse dialog shows the selected character positions extracted and output as desired. Simultaneously, the data string from the actual selected symbol is displayed at the bottom left of the Parse Table, followed by the user-defined extracted output.
14-6
Quadrus MINI Velocity User’s Manual
Page 353
Output Format
Format Insert Output Index Definition:
Output Index refers to the database entry you wish to modify with this command. A formatted output is built by extracting data from a symbol’s original data output and/or inserting user-defined characters. It may be helpful to think of individual indexes as positions in the final formatted output you wish to build. Starting with index # 1, enter either an extract or insert command to begin building your desired output string. Then, with the next index number, enter either an extract or insert command to continue building the output string. Continue this process until you are finished building the string.
Serial Cmd: <K741,output index,length,hex string> Options:
1 to 100
Length Definition:
Specifies the length of the user-defined character string that will be inserted. This function is limited to 4 characters per output index, so multiple indexes must be entered in order to insert longer character sequences. For example, if you wish to insert a 10 character sequence in user-defined output, you would need three commands with consecutive index numbers, where the first two character sequence lengths were 4 and the third was 2.
Serial Cmd: <K741,output index,length,hex string> Default:
0 (disabled; end of format cell array)
Options:
1 to 4
Hex String Definition:
Specifies a character string that represents ASCII characters to be inserted in the database entry. Two hex characters are required for every ASCII character to be inserted in the user-defined output string. These two characters comprise the hex (base 16) value of the ASCII character. For example, if you wanted to enter the three-character sequence “Hi!” you would enter 3 for the length of the string, and a hex sequence of 486921 for the ASCII sequence to be inserted. (48 = H; 69 = i; 21 = !) Important: Each pair of hex characters represents one ASCII character. Hex character pairs range from 00 to FF. Since you are limited to 4 ASCII characters per insertion per database entry, you are likewise limited to 8 hex characters per insertion per database entry.
Serial Cmd: <K741,output index,length,hex string> Default:
NUL (00 in hex)
Options: 00 to FF (As many as 4 bytes, or hex pairs.) See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. Quadrus MINI Velocity User’s Manual
14-7
Page 354
Format Insert
Format Insert by ESP
The Format Insert process is very similar to the Format Extract process, except that Insert allows you to enter characters using the Insertion Calculator (shown above).
Notice that Extract and Insert share the same Parse Table.
14-8
Quadrus MINI Velocity User’s Manual
Page 355
Output Format
Output Filter Configuration Definition:
Output filtering is a method of providing a set of good read qualifiers and also providing ordered output. There is a filter for up to the first 10 positions in a multisymbol output. The first filter corresponds to the first symbol output at the end of the read cycle. Each filter has has settings for the following four parameters: Symbology Type, Symbol Length, Data, and Configuration Database Number.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index>
Rules for Output Filter Configuration Output Filter Configuration Rule # 1 Each symbol that is decoded must match one of the filters before it can be saved to a read cycle record. There is an exception to this rule, however, when the number of symbols required for a read cycle exceeds the number of active filters. In such a case, unfiltered symbols can be placed into unfiltered output positions. For example, if the number of symbols required is 6 but there are only 4 active filters, the last 2 positions can be filled by any (unfiltered) qualified symbol.
Output Filter Configuration Rule # 2 The same filter setup can be used multiple times. For example, filters 1, 2, and 3 can be set up to filter Data Matrix symbols, and the output will occur in the order the symbols are decoded.
Output Filter Configuration Rule # 3 All qualified symbols will be sorted and output in the matching filter position. If a symbol matches filter 3, it will be output as the third symbol. If a filter does not have a matching qualified symbol, a No Read message will be output in place of the symbol (assuming the No Read message is enabled). For example, if there is not a symbol that meets filter 3’s requirements, then a No Read message will be output in the third output position.
Quadrus MINI Velocity User’s Manual
14-9
Page 356
Output Filter Configuration
Filter Number Definition:
This is the filter index number that represents the position of the symbol in the data output at the end of the read cycle. This index number should be entered along with the following filter settings for the predetermined symbol position.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Options:
1 to 10
Symbology Type Definition:
Specifies the symbology type allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all the requirements of the selected filter index.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
0 (any symbology type)
Options:
0 = Any type 1 = Interleaved 2 of 5 2 = Code 39 3 = Code 128 4 = Codabar 5 = UPC 6 = PDF417 7 = EAN 128 8 = Code 93 9 = Pharmacode 10 = GS1 DataBar (RSS) 11 = MicroPDF417 12 = Composite 13 = BC412 14 = Data Matrix 15 = QR Code 16 = Micro QR Code (Only supported when Q-Mode is enabled.) 17 = Aztec Code (Only supported when Q-Mode is enabled.) 18 = Postal Symbologies (Only supported when Q-Mode is enabled.) 19 = OCR
14-10
Quadrus MINI Velocity User’s Manual
Page 357
Output Format
Length Definition:
Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
0
Options:
0 to 64
Wildcard Definition:
This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
“ * “ = (2A in hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 2A = * 00 = disabled
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Placeholder Definition:
The placeholder character requires a character to be present, but does not compare the data value.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
“ ? ” = (3F in hex)
Options:
Any ASCII input in the form of a pair of hex characters. Example: 3F = ? 00 = disabled
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Quadrus MINI Velocity User’s Manual
14-11
Page 358
Output Filter Configuration
Data Definition:
This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
NUL (00 in hex)
Options:
Any ASCII input in the form of a pair of hex characters. Maximum length: 63 bytes defined. Examples: 41422A = AB* Data [0] = NUL represents string matching disabled.
See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Database Index Definition:
The index of the database entry that decodes a given symbol must equal this setting for filtering to occur. A setting of 0 allows any database index for this filter entry.
Serial Cmd: <K744,filter number,symbology type,length,wildcard,placeholder,data, unused,database index> Default:
0 (any index)
Options:
0 to 10
14-12
Quadrus MINI Velocity User’s Manual
Page 359
Output Format
Ordered Output Filter Definition:
Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.
Serial Cmd: <K745,number of filters> Default:
0
Options:
0 to 10