The text of a manual · part 34 of 42
Quadrus MINI Velocity User's Manual, pages 331 to 340
Pages 331 to 340 of 419
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MINI VELOCITY
Page 331
Utilities
Master Database Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Usage: Definition:
Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands.
1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which you want to enter the master symbol. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Loads the next symbol decoded into the selected index.
Double-click a row to enter data into popup dialog box. Loads the imager’s saved master symbols into ESP.
Quadrus MINI Velocity User’s Manual
Saves the displayed database to the imager.
13-9
Page 332
Master Database
Master Symbol Database Size Definition: Serial Cmd: Default: Options:
Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database. <K231,master symbol database size> Note: You must follow this command with a save command <A> or <Z>. 1 1 to 10
Set Master Symbol Database Size here.
Caution: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5
13-10
Maximum Characters 3000 1500 1000 750 600
Master Symbol Number #6 #7 #8 #9 # 10
Maximum Characters 500 428 375 333 300
Quadrus MINI Velocity User’s Manual
Page 333
Utilities
Enter Master Symbol Data Usage:
Allows you to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Serial Cmd: <K231,master symbol number,master symbol data> Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the maximum allowed. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols, send <K231,9,data>. Important: The ASCII characters <, >, and , can only be entered as hex pairs. See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. ESP:
Caution: If no data is entered, the existing data will be deleted. 1. Open the Utilities menu. 2. Set the number of master symbols you want to create in Master Symbol Database Size. 3. Double-click on each symbol number you want to set up and copy, or type your data in the popup dialog and click OK.
4. When all your data has been entered, click the Send Database to the Reader button. Quadrus MINI Velocity User’s Manual
13-11
Page 334
Request Master Symbol Data Definition:
Serial Cmd:
Returns master symbol data for any enabled master symbols from 1 to 10. For example, to request master symbol # 5, enter <K231?,5>. The imager transmits master symbol # 5 data in brackets in the following format: <5/>. If no master symbol data is available, the output will be: <5/>. <K231?,master symbol number> Caution: Be sure to add the ? or you will delete the master symbol. Note: This command returns the number of master symbols if no number is included.
ESP:
1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Request All Master Symbol Data Definition: Serial Cmd:
13-12
This command will return master symbol data for all symbols enabled (up to 10). <K231?>
Quadrus MINI Velocity User’s Manual
Page 335
Utilities
Read Next Symbol as Master Symbol Definition: Serial Cmd:
ESP:
After you’ve set the size in the database, you can order the imager to read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab under the Output Format menu, 1. Select the master symbol index number in which you want to store the symbol data. 2. Click the Read Symbol into Selected Index button. Caution: If you’ve selected an index which already has existing data, that data will be copied over by new decoded data when you use this command.
Request New Master Status Usage: Definition: Serial Cmd:
Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. <NEWM> The imager returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
(See also New Master Pin in Chapter 9, Matchcode.)
Quadrus MINI Velocity User’s Manual
13-13
Page 336
Delete Master Symbol Data Definition: ESP:
Serial Cmd:
13-14
You can directly delete the master symbol data by serial command or by ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number you want to delete. 3. Delete text and click OK. <K231,master symbol number,> To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol # 5, send the following: <K231,5,>. The command is entered with a blank master symbol data field, which tells the imager to delete the selected master symbol from the database.
Quadrus MINI Velocity User’s Manual
Page 337
Utilities
Firmware Firmware by ESP
Firmware Update Firmware Update is used to download application code to the imager. Application code versions are specific to your imager. Consult with your sales representative before downloading application code. If needed, an application/boot code will be sent to you in the form of a *.mot file. To download application code: 1. First, be sure that your imager is connected to the host computer. 2. Apply power to the imager. 3. In the Firmware Update dropdown menu, select App Code. This will open a dialog that allows you to browse for the application code file. 4. Navigate to where the application code file (a *.mot file) is located on your host computer. 5. Allow approximately a minute for firmware to download. As the application code begins to download, the imager will be silent, the LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will let you know when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.
Quadrus MINI Velocity User’s Manual
13-15
Page 338
Firmware
Firmware Verification Request Part Number by ESP You can send a request to the imager for part numbers, checksums, boot code, and application code. 1. Click the Firmware tab in ESP’s Utilities. 2. From the dropdown menu to the left of the Request Part No. button, make your selection. 3. Select the code type to see its part number displayed in the text field to the right of the Request Part No. button.
Request Part Number by Serial Command • When you send <#> (a request for all product part numbers), the imager returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When you send <#a> (a request for the application code part number), the imager returns: <#a/APP_P/N>. • When you send <#b> (a request for the boot code part number), the imager returns: <#b/BOOT_P/N>. • When you send <#p> (a request for profile module part numbers), the imager returns: <#p/PROFILE_P/N>.
13-16
Quadrus MINI Velocity User’s Manual
Page 339
Utilities
Request Checksum by ESP You can send a request to the imager for part numbers, checksums, boot code, and application code. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Checksum button, make your selection. 3. Select the code type to see its checksum displayed in the text field to the right of the Request Checksum button.
Request Checksum by Serial Command • When you send <!> (a request for all available firmware checksums), the imager returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When you send <!a> (a request for the application code checksum), the imager returns: <!a/APP_CHECKSUM> • When you send <!b> (a request for the boot code checksum), the imager returns: <!b/BOOT_CHECKSUM> • When you send <!p> (a request for profile module checksum), the imager returns: <!p/PROFILE_CHECKSUM>
Quadrus MINI Velocity User’s Manual
13-17
Page 340
Default/Reset/Save
Default/Reset/Save Understanding and controlling your imager’s active, saved, and default settings is critical to its successful operation.
Saved for Power-on
Resets (not saved for power-on)
Function
Serial Cmd
<Ard>
No
<ArdWB>
No
No
<Arp>
No
No
<Arc>
No
No
<A>
Reset and Recall Microscan Defaults Reset and Recall Microscan White Balance Defaults Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Save Current Settings for Power-On
<Z>
Save Current Settings as Customer Default Parameters for Power-On
<Zc>
Recall Customer Default Parameters and Save for Power-On
EZ Button
Save to Reader, Send No Save No
Reset
Recall Microscan Default Parameters and Save for Power-On Reset Microscan Default White Balance Parameters and Save for Power-On
ESP (first, right-click in any menu tree)a
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb
No
No No
<Zrd>
No
No
<ZrdWB>
No
No
<Zrc>
No
Press and hold while powering on Imager a. When you right-click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the reader itself, you need to follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled under the Options pulldown menu.
Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the imager or the <Arp> command is issued.
Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
13-18
Quadrus MINI Velocity User’s Manual