For the Microscan MINI VELOCITY
Page 311
Configuration Database
Region of Interest (ROI) by ESP When Image Dimensions is set to Region of Interest, the database image dimension parameters are IP and decode settings, and they determine the region or area of the captured image to be processed.
Threshold Mode, Fixed Threshold Value, Processing Mode, Narrow Margins, Background, and Symbol Type are all Processing Settings values.
Quadrus MINI Velocity User’s Manual
11-15
Page 312
Save Current Settings to Configuration Database
Save Current Settings to Configuration Database Definition: Serial Cmd:
Allows current, active configuration settings to be saved to a selected database index. <K255+,index>
Example: <K255+,5> This command phrase saves the imager’s current, active configuration settings to database index 5.
Save Current Settings to Configuration Database by ESP
Click the Load Current to Index button to save the imager’s current configuration parameters to the selected database index.
11-16
Quadrus MINI Velocity User’s Manual
Page 313
Configuration Database
Load Current Settings from Configuration Database Definition: Serial Cmd:
Allows the configuration settings contained in a selected database index to be loaded to current, active configuration settings. <K255-,index>
Example: <K255-,5> This command phrase loads the configuration settings contained in database index 5 to current, active configuration settings.
Load Current Settings from Configuration Database by ESP
Click the Load Index to Current button to load configuration settings from the selected index to current, active settings.
Notes on Symbol Type • The current DataBar Expanded status does not change if it is configured as Enabled (Stacked) and the database DataBar Expanded status is Enabled. • The current DataBar-14 status does not change if it is configured as Enabled (Stacked) and the database DataBar Expanded status is Enabled. • Data Matrix ECC level is determined by the current settings and not by database settings. Therefore, the database does not know which ECC level to enable, and has no effect on current Data Matrix ECC settings.
Quadrus MINI Velocity User’s Manual
11-17
Page 314
Request Selected Index Settings
Request Selected Index Settings Definition: Serial Cmd:
Returns configuration settings for the selected database index. <K255?,index>
Example: <K255?,5> This command phrase returns the configuration settings for database index 5.
11-18
Quadrus MINI Velocity User’s Manual
Page 315
Configuration Database
Request All Configuration Database Settings Definition: Serial Cmd:
Returns configuration settings for all indexes in the configuration database. <K255?>
Example: <K255?> This command phrase returns the configuration settings for all 10 database indexes.
Quadrus MINI Velocity User’s Manual
11-19
Page 316
Request All Configuration Database Settings
11-20
Quadrus MINI Velocity User’s Manual
Page 317
12 Terminal Contents Terminal Window........................................................................................................................ 12-2 Find ............................................................................................................................................ 12-3 Send ........................................................................................................................................... 12-4 Macros........................................................................................................................................ 12-5 Terminal Window Menus............................................................................................................ 12-6
This section describes the Terminal window and macro functions in ESP.
Quadrus MINI Velocity User’s Manual
12-1
Page 318
Terminal Window
Terminal Window Click this button to display the Terminal view. The following view will appear: Copy, paste, save
Clear screen
Type text here to find matching text in the Terminal window.
Terminal screen
Macros listed on this bar
Type serial commands here.
Click on desired Macro to run. Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.
The Terminal screen allows you to send serial commands to the imager by using Macros, by copying and pasting, or by typing commands in the Send text field. The Terminal screen also displays symbol data or information from the imager. You can also right-click on the Terminal screen to bring up a menu of further options.
12-2
Quadrus MINI Velocity User’s Manual
Page 319
Terminal
Find The Find function allows you to enter text strings to be searched for in the Terminal window. For example, a series of symbols have been scanned into the Terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1. Type “ABC” into the Find box.
2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the left of the text field to locate additional instances of “ABC”.
Quadrus MINI Velocity User’s Manual
12-3
Page 320
Send
Send The Send function allows you to enter serial commands and then send them to the imager. 1. Type the command into the Send box.
2. Press Enter. 3. Click the Send button to the left of the text field to send .
12-4
Quadrus MINI Velocity User’s Manual