The text of a manual · part 21 of 42
Quadrus MINI Velocity User's Manual, pages 201 to 210
Pages 201 to 210 of 419
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MINI VELOCITY
Page 201
I/O Parameters
Target Pattern Usage: Definition: Serial Cmd: Default: Options:
Assists users in positioning and locating symbols in the center of the imager’s field of view. The user can control when the targeting system is ON or OFF, and can save this condition for power-on. <K750,green flash mode,target pattern status,green flash duration> Always ON 0 = Always OFF 1 = ON only when not in the read cycle 2 = ON only when in the read cycle 3 = Always ON
Always OFF The target pattern will remain OFF at all times unless overridden by the EZ Button or operational command.
ON Only When Not in the Read Cycle The target pattern is always ON except during the read cycle. If the EZ Button or operational command overrides this setting, the target pattern will remain on at all times.
ON Only When in the Read Cycle The target pattern will remain OFF except during the read cycle. If the EZ Button or operational command overrides this setting, the target pattern will remain on at all times.
Always ON The target pattern is always ON.
Quadrus MINI Velocity User’s Manual
7-21
Page 202
Output Indicators
Green Flash Duration Usage: Definition: Serial Cmd: Default: Options:
7-22
Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value. <K750,green flash mode,target pattern status,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)
Quadrus MINI Velocity User’s Manual
Page 203
I/O Parameters
Beeper Usage: Definition: Serial Cmd: Default: Options:
An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. <K702,beeper status> Good Read 0 = Disabled 1 = Good Read 2 = No Read
Note: The beeper will also sound at any of the following times: • When the imager is defaulted. • When a send/save command is sent from ESP. • At the conclusion of a calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent.
Quadrus MINI Velocity User’s Manual
7-23
Page 204
LED Configuration
LED Configuration Usage: Definition: Serial Cmd: Default: Options:
Useful as a visible indicator of read rates and symbol quality. Determines the mode in which the status LEDs operate. <K737,LED mode,ISO/IEC 16022 grade> Standard 0 = Standard 1 = ISO/IEC 16022 grade
In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix symbol decoded in the read cycle. The parameter to be graded is set in the ISO/IEC 16022 Grade options. For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all the LEDs from 20% to 100% are illuminated, the read result is a grade A; if only the 20% LED is illuminated, the result is a grade F.
Standard In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle. In a read rate test, these LEDs represent the percentage of good reads per images captured.
ISO/IEC 16022 Grade Usage: Definition: Serial Cmd: Default: Options:
7-24
Provides visual grading of specific ISO/IEC 16022 parameters. Determines which ISO/IEC 16022 parameter the imager will grade via the LEDs. <K737,LED mode,ISO/IEC 16022 grade> Final Grade 0 = Final Grade 1 = Symbol Contrast 2 = Print Growth 3 = Axial Non-Uniformity 4 = Unused ECC
Quadrus MINI Velocity User’s Manual
Page 205
I/O Parameters
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status Usage:
Definition:
Function:
Serial Cmd: Default: Options:
This command is useful in removing any doubt about the imager’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the imager will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the Host Imager host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Usage: Definition: Function:
Serial Cmd: Default: Options:
Used to audibly verify the acceptance and validity of a command. Causes the imager to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the imager beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Velocity User’s Manual
7-25
Page 206
Serial Verification
Control/Hex Output Usage: Definition:
Serial Cmd: Default: Options:
7-26
Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M. <K701,serial command echo status,serial command beep status,control/hex output> Control 0 = Control 1 = Hex
Quadrus MINI Velocity User’s Manual
Page 207
I/O Parameters
EZ Button The EZ Button has four positions, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight options. Definition: Serial Cmd: Default: Options:
Serves as a master switch to enable/disable the EZ Button status. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch
Global Status Disabled When set to Disabled, the EZ Button does not function.
Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Mode command.
Trigger When selected, the EZ Button acts as a trigger for the imager to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:
The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and Timeout is enabled for End of Read Cycle. As with Level, Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike Level, the read cycle ends with a good read output, a timeout, or a new trigger.
Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.
Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.
Quadrus MINI Velocity User’s Manual
7-27
Page 208
EZ Button
Default on Power-On Definition:
Serial Cmd: Default: Options:
When enabled, if the EZ Button is held down on power-on the imager will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled
Load Configuration Database Definition:
Serial Cmd: Default: Options:
Allows the user to load the Configuration Database with calibration results. When the user performs a calibration using the EZ Button, all the database entries are moved down one index and the results of the calibration are saved to index 1. The results will be saved as current settings as well. <K770,global status,default on power-on,load configuration database, save for power-on> Enabled 0 = Disabled 1 = Enabled
Save for Power-On Definition: Serial Cmd: Default: Options:
7-28
If enabled, after calibration is complete, all parameters will be saved for power-on. <K770,global status,default on power-on,load configuration database, save for power-on> Disabled 0 = Disabled 1 = Enabled
Quadrus MINI Velocity User’s Manual
Page 209
I/O Parameters
EZ Button Modes Usage: Definition: Serial Cmd: Options:
Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 8 modes. <K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode> 0 = Disabled 1 = Enabled
Single Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Bar Code Config.
Disabled When set to disabled, the associated button position will have no function associated with it, and the position will be skipped over.
Read Rate Read Rate will be initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button.
Calibrate Calibration will be initiated when the associated button position is selected. To abort calibration, quickly press and release the EZ Button.
Save for Power-On All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from the Terminal.
Load New Master Functions in the same way as new master pin input whenever the associated button position is selected. The new master pin’s Consecutive Decode requirement holds true for this function. Quadrus MINI Velocity User’s Manual
7-29
Page 210
EZ Button Modes
Target System Turns on the target pattern whenever the associated button position is selected. To disable, quickly press and release the EZ Button. Note: This mode is the only one that does not require that the button be released before taking effect. Thus, as soon as the imager beeps the appropriate number of times for the position, it will take effect. If it is necessary to have the target system on before another operation such as calibration or read rate is performed, ensure that the target system mode is assigned a lower position so that it will be activated first.
Bar Code Configuration Enables bar code configuration mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.
7-30
Quadrus MINI Velocity User’s Manual